This study seeks to describe the rollout and current state of South Africa’s GeneXpert molecular diagnostic program for tuberculosis (TB). Xpert MTB/RIF was introduced in 2011 with a subsequent expansion to include extra-pulmonary and paediatric testing, followed by Xpert MTB/RIF Ultra in 2017. Through a centralised laboratory information system and the use of a standardised platform for more than a decade, over 23 million tests were analysed, describing the numbers tested, Mycobacterium tuberculosis complex detection, rifampin resistance, and the unsuccessful test rates. The stratification by province, specimen type, age, and sex identified significant heterogeneity across the program and highlighted testing gaps for men, low detection yield for paediatric pulmonary TB, and the effects of inadequate specimen quality on the detection rate. The insights gained from these data can aid in the monitoring of interventions in support of the national TB program beyond laboratory operational aspects.
HIV viral load (VL) testing plays a key role in the clinical management of HIV as a marker of adherence and antiretroviral efficacy. To date, national and international antiretroviral treatment recommendations have evolved to endorse routine VL testing. South Africa (SA) has recommended routine VL testing since 2004. Progressively, the centralised HIV VL program managed by its National Health Laboratory Service (NHLS) has undergone expansive growth. Retrospective de-identified VL data from 2013 to 2022 were evaluated to review program performance. Test volumes increased from 1,961,720 performed in 2013 to 45,334,864 in 2022. The median total in-laboratory turnaround time (TAT) ranged from 94 h (2015) to 51 h (2022). Implementation of two new assays improved median TATs in all laboratories. Samples of VL greater than 1000 copies/mL declined steadily. Despite initial increases, samples of fewer than 50 copies/mL stagnated at about 70% from 2019 and declined to 68% in 2022. Some variations between assays were observed. Overall, the SA VL program is successful. The scale of the VL program, the largest of its kind in the world by some margin, provides lessons for future public health programs dependent on laboratories for patient outcome and program performance monitoring.
An investigation was carried out to examine the use of national Xpert MTB/RIF data (2013–2017) and GIS technology for MTB/RIF surveillance in South Africa. The aim was to exhibit the potential of using molecular diagnostics for TB surveillance across the country. The variables analysed include Mycobacterium tuberculosis (Mtb) positivity, the mycobacterial proportion of rifampicin-resistant Mtb (RIF), and probe frequency. The summary statistics of these variables were generated and aggregated at the facility and municipal level. The spatial distribution patterns of the indicators across municipalities were determined using the Moran’s I and Getis Ord (Gi) statistics. A case-control study was conducted to investigate factors associated with a high mycobacterial load. Logistic regression was used to analyse this study’s results. There was striking spatial heterogeneity in the distribution of Mtb and RIF across South Africa. The median patient age, urban setting classification, and number of health care workers were found to be associated with the mycobacterial load. This study illustrates the potential of using data generated from molecular diagnostics in combination with GIS technology for Mtb surveillance in South Africa. Spatially targeted interventions can be implemented in areas where high-burden Mtb persists.
The Xpert® Xpress SARS-CoV-2 and Xpert® Xpress SARS-CoV-2/Flu/RSV tests were rapidly developed and widely used during the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. In response to emerging genetic variability, a new SARS-CoV-2 target (RNA-dependent RNA-polymerase) has been added to both tests: Xpert® Xpress CoV-2 plus and Xpert® Xpress CoV-2/Flu/RSV plus test. A rapid evaluation of both tests was performed in South Africa, using residual respiratory specimens. Residual respiratory specimens (n = 125) were used to evaluate the Xpert® Xpress CoV-2 plus test and included 50 genotyped specimens. The Xpert® Xpress CoV-2/Flu/RSV plus test was assessed using 45 genotyped SARS-CoV-2 specimens, 10 influenza A, 10 influenza B and 20 respiratory syncytial virus specimens. Results were compared to in-country standard-of-care tests. Genotyped specimens tested the performance of the test under pressure from circulating SARS-CoV-2 variants of concern. Reference material was included to assess the test limits and linearity. The Xpert® Xpress CoV-2 plus test performance compared to reference results across residual respiratory specimens was good (positive percentage agreement (PPA) = 95.2%, negative percentage agreement (NPA) = 95.0%) The Xpert® Xpress CoV-2/Flu/RSV plus test showed good performance across all residual respiratory specimens (PPA = 100%, NPA = 98.3%). All genotyped variants of concern were detected by both tests. The Xpert® Xpress CoV-2 plus and Xpert® Xpress CoV-2/Flu/RSV plus tests can be used to diagnose SARS-CoV-2, and to diagnose and differentiate SARS-CoV-2, influenza A, influenza B and respiratory syncytial virus, respectively. The NPA was lower than the recommended 99%, but was influenced by the low number of negative specimens tested. The variants of concern assessed did not affect test performance. It is recommended that sites perform their own assessments compared to in-country standard-of-care tests.
13 October 2022 in The Journal of Molecular Diagnostics
Four moderate-complexity automated nucleic acid amplification tests for the diagnosis of tuberculosis are reported as having laboratory analytical and clinical performance similar to that of the Cepheid Xpert MTB/RIF assay. These assays are the Abbott RealTime MTB and RealTime MTB RIF/INH Resistance, Becton Dickinson MAX MDR-TB, the Hain Lifescience/Bruker FluoroType MTBDR, and the Roche cobas MTB and MTB RIF/INH assays. The study compared feasibility, ease of use, and operational characteristics of these assays/platforms. Manufacturer input was obtained for technical characteristics. Laboratory operators were requested to complete a questionnaire on the assays' ease of use. A time-in-motion analysis was also undertaken for each platform. For ease-of-use and operational requirements, the BD MAX MDR-TB assay achieved the highest scores (86% and 90%) based on information provided by the user and manufacturer, respectively, followed by the cobas MTB and MTB-RIF/INH assay (68% and 86%), the FluoroType MTBDR assay (67% and 80%), and the Abbott RT-MTB and RT MTB RIF/INH assays (64% and 76%). The time-in-motion analysis revealed that for 94 specimens, the RealTime MTB assay required the longest processing time, followed by the cobas MTB assay and the FluoroType MTBDR assay. The BD MAX MDR-TB assay required 4.6 hours for 22 specimens. These diagnostic assays exhibited different strengths and weaknesses that should be taken into account, in addition to affordability, when considering placement of a new platform.
The high demand for SARS-CoV-2 tests but limited supply to South African laboratories early in the COVID-19 pandemic resulted in a heterogenous diagnostic footprint of open and closed molecular testing platforms being implemented. Ongoing monitoring of the performance of these multiple and varied systems required novel approaches, especially during the circulation of variants. The National Health Laboratory Service centrally collected cycle threshold (Ct) values from 1,497,669 test results reported from 6 commonly used PCR assays in 36 months, and visually monitored changes in their median Ct within a 28-day centered moving average for each assays’ gene targets. This continuous quality monitoring rapidly identified delayed hybridization of RdRp in the Allplex™ SARS-CoV-2 assay due to the Delta (B.1.617.2) variant; S-gene target failure in the TaqPath™ COVID-19 assay due to B.1.1.7 (Alpha) and the B.1.1.529 (Omicron); and recently E-gene delayed hybridization in the Xpert® Xpress SARS-CoV-2 due to XBB.1.5. This near “real-time” monitoring helped inform the need for sequencing and the importance of multiplex molecular nucleic acid amplification technology designs used in diagnostics for patient care. This continuous quality monitoring approach at the granularity of Ct values should be included in ongoing surveillance and with application to other disease use cases that rely on molecular diagnostics.