Selecting a battery energy storage technology for application on offshore platforms or marine vessels can be a challenging task. Offshore oil and gas platforms (OOGPs) require battery energy storage systems (BESSs) with high volumetric density, high gravimetric density, high safety, a long life span, low maintenance, and good operational experience, amongst other BESS properties. No single battery chemistry can satisfy all these factors perfectly, which implies that there is a need for a method that determines the most suitable battery chemistry for a given application. To this end, this paper proposes an improved version of a 7-step procedure proposed in the literature to systematically and logically determine the most suitable BESS for high-energy applications on OOGPs. In order to implement the 7-step procedure, a review of the state-of-the-art of consolidated and emerging battery chemistry is done. As part of the 7-step procedure, the operational experience of the battery chemistry was also reviewed. The 7-step procedure was then applied to a case study (with two test cases) of a real OOGP in the North Sea. The first test case considers BESS for peak shaving, for which six battery chemistries were assessed in detail. A technology suitability assessment (TSA) weighted score is calculated, which is based on five attributes critical for the energy storage choice in the considered application, which are weight, space, safety, life cycle cost, and operational experience. Of the six battery chemistries assessed, lithium iron phosphate (LFP) has the highest technology suitability assessment (TSA) weighted score and is therefore deemed the most suitable battery chemistry for peak shaving. The second test case considers BESS for spinning reserve. Since this is a high C-rate application, only battery chemistry capable of high C-rate was evaluated. From the TSA evaluation, LFP and lithium nickel manganese cobalt have the joint highest TSA weighted score and are therefore deemed the most suitable battery chemistry for spinning reserve.
13 April 2023 in IEEE Open Journal of Industry Applications
Power hardware-in-the-loop (PHIL) is an experimental technique that uses power amplifiers and real-time simulators for studying the dynamics of power electronic converters and electrical grids. PHIL tests provide the means for functional validation of advanced control algorithms without the burden of building high-power prototypes during early TRL. However, replicating the behavior of high-power systems with laboratory SDC can be complex. Inaccurate scaling of the SDC coupled with an exclusive focus on instantaneous voltages and currents at the fundamental frequency can lead to PHIL results that are only partially relatable to the high-power systems under study. Test beds that fail to represent switching frequency harmonics cannot be used for studying harmonic penetration or loss characterization of large-scale converters. To tackle this issue, this paper proposes a harmonic-invariant scaling method (HISM) that exploits the VA rating of preexisting laboratory SDCs for more accurately replicating harmonic phenomena in a PHIL test bench. Firstly,, a theoretical analysis of the proposed method is presented and, subsequently, the method is validated with MATLAB simulations and experimental tests.
This paper aims to analyze the effect of high penetration of floating offshore wind-based power generation on the power quality of a Floating Production Storage and Offloading (FPSO) power system. The paper focuses on the continuous frequency variation caused by intermittent wind power generation and an energy storage-based solution for power smoothing. A set of results simulated in MATLAB/Simulink® is shown to assess different operational scenarios of a typical Brazilian FPSO from the Mero Oil Field, powered by 109 MVA/ 87 MW from three synchronous generators, without wind power. Wind power penetration varies from 10 to 50 MW, and the effects of this variation on FPSO power quality are reported. Then, the number of gas turbine generators is reduced from 3 to 2 generators. Finally, the energy storage for power smoothing purposes is evaluated. Conclusions are drawn based on steady-state and transient voltage and frequency profiles, active and reactive power flow between loads and generation, the rate of change of frequency, and frequency nadir.
The emerging penetration of converter-based generation through offshore wind turbines and battery energy storage systems (BESSs) aims to reduce carbon emissions in modern offshore oil and gas platforms (OOGPs). This system represents a unique and challenging test case for studies related to power system flexibility and resilience. The new onboard converter-interfaced devices together can provide various grid services, including voltage regulation, frequency response, reactive power control, and peak shaving. Moreover, in the event of an outage, BESS converters can help to restore power rapidly, thus enhancing power system resilience. It can be established that enhanced flexibility and resilience on modern OOGPs is possible only with cooperation of power electronic converters, such as those of variable frequency drives (VFDs), wind turbines, BESSs, and active power filters (APFs). By working together, these technologies can maximize their exploitability, enhance efficiency of gas turbine generators and/or reduce the need for them, and increase resilience by integrating BESSs endowed with grid-forming capability. Hence, this article explores diverse case study scenarios, providing valuable insights into the necessity and opportunities for cooperation among different devices on the platform. This marks a step forward in OOGPs’ green transition, potentially serving as a useful paradigm for several other autonomous systems.