Kenneth C Bilchick

Dr. Kenneth C Bilchick


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2007 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
JDJun Dong
Jun Dong
DDDarshan Dalal
Darshan Dalal
USUniv.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Univ.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
ACAamir Cheema
Aamir Cheema
SNSaman Nazarian
Saman Nazarian
HCHugh Calkins
Hugh Calkins

1 July 2002 in The American Journal of Cardiology
Verified
Journal Article
Closed access
KBKenneth C Bilchick
Kenneth C Bilchick
BFBarry Fetics
Barry Fetics
RDRonnie Djoukeng
Ronnie Djoukeng
SFSusan Gross Fisher
Susan Gross Fisher
RFRoss D Fletcher
Ross D Fletcher
RBRonald D Berger
Ronald D Berger

16 November 2010 in Circulation
Verified
Journal Article
Closed access
PDF file
KBKenneth C Bilchick
Kenneth C Bilchick
SKSandeep Kamath
Sandeep Kamath
JDJohn P. DiMarco
John P. DiMarco
GSGeorge J. Stukenborg
George J. Stukenborg
Background—: Clinical trials of cardiac resynchronization therapy (CRT) have enrolled a select group of patients, with few patients in subgroups such as right bundle-branch block (RBBB). Analysis of population-based outcomes provides a method to identify real-world predictors of CRT outcomes. Methods and Results—: Medicare Implantable Cardioverter-Defibrillator Registry (2005 to 2006) data were merged with patient outcomes data. Cox proportional-hazards models assessed death and death/heart failure hospitalization outcomes in patients with CRT and an implantable cardioverter-defibrillator (CRT-D). The 14 946 registry patients with CRT-D (median follow-up, 40 months) had 1-year, 3-year, and overall mortality rates of 12%, 32%, and 37%, respectively. New York Heart Association class IV heart failure status (1-year hazard ratio [HR], 2.23; 3-year HR, 1.98; P <0.001) and age ≥80 years (1-year HR, 1.74; 3-year HR, 1.75; P <0.001) were associated with increased mortality both early and late after CRT-D. RBBB (1-year HR, 1.44; 3-year HR, 1.37; P <0.001) and ischemic cardiomyopathy (1-year HR, 1.39; 3-year HR, 1.44; P <0.001) were the next strongest adjusted predictors of both early and late mortality. RBBB and ischemic cardiomyopathy together had twice the adjusted hazard for death (HR, 1.99; P <0.001) as left BBB and nonischemic cardiomyopathy. QRS duration of at least 150 ms predicted more favorable outcomes in left BBB but had no impact in RBBB. A secondary analysis showed lower hazards for CRT-D compared with standard implantable cardioverter-defibrillators in left BBB compared with RBBB. Conclusions—: In Medicare patients, RBBB, ischemic cardiomyopathy, New York Heart Association class IV status, and advanced age were powerful adjusted predictors of poor outcome after CRT-D. Real-world mortality rates 3 to 4 years after CRT-D appear higher than previously recognized.

1 September 2008 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
KBKenneth C Bilchick
Kenneth C Bilchick
VDVeronica Dimaano
Veronica Dimaano
KWKatherine C. Wu
Katherine C. Wu
RHRobert H. Helm
Robert H. Helm
RWRobert G. Weiss
Robert G. Weiss
ALAlbert C. Lardo
Albert C. Lardo

1 December 2009 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
JFJohn D. Ferguson
John D. Ferguson
AHAdam Helms
Adam Helms
JMJ. Michael Mangrum
J. Michael Mangrum
SMSrijoy Mahapatra
Srijoy Mahapatra
PMPamela Mason
Pamela Mason
JDJohn P. DiMarco
John P. DiMarco
Background— Catheter ablation of atrial fibrillation is currently guided by x-ray fluoroscopy. The associated radiation risk to patients and medical staff may be significant. We report an atrial fibrillation ablation technique using intracardiac echocardiography (ICE) and electroanatomic mapping without fluoroscopy. Methods and Results— Twenty-one patients with atrial fibrillation (age, 42 to 73 years; 14 male; 14 paroxysmal, 7 persistent; body mass index, 26 to 38) underwent ablation. A decapolar catheter was advanced through the left subclavian vein until stable coronary sinus electrograms appeared on all electrodes. Two 9F sheaths were advanced transfemorally over a guide wire to the right atrium. A rotational ICE catheter was advanced through a deflectable sheath. Double transseptal puncture was performed with ICE guidance and facilitated by electrocautery. A 3D MRI left atrial image was registered to the ostia of the pulmonary veins using ICE. Catheter ablation was performed using ICE and electroanatomic mapping navigation. In 19 cases, no fluoroscopy was used and the staff did not wear protective lead. In 2 cases, 2 to 16 minutes of fluoroscopy was used to assist transseptal puncture. Median procedure time was 208 (188 to 221) minutes; coronary sinus cannulation took 5 (2 to 26) minutes; double transseptal took 26 (17 to 40) minutes; left atrial ablation time was 103 (90 to 127) minutes. All patients underwent circumferential pulmonary vein ablation and 8 patients underwent additional left atrial ablation. There were no procedure-related complications. Conclusions— Catheter ablation of atrial fibrillation without fluoroscopy is feasible and merits further attention. This technique may be especially helpful in preventing x-ray exposure in children, pregnant women, and obese patients undergoing left atrial ablation.

1 October 2012 in JACC
Verified
Journal Article
Closed access
KBKenneth C Bilchick
Kenneth C Bilchick
GSGeorge J. Stukenborg
George J. Stukenborg
SKSandeep Kamath
Sandeep Kamath
ACAlan Cheng
Alan Cheng