Iftikhar Ud ud Din

Prof. Iftikhar Ud ud Din

Telecommunication, University of Engineering and Technology, Peshawar, Khyber Pakhtunkhwa, Pakistan

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2024 in IEEE Photonics Journal
Verified
Journal Article
Open access
Musa N. HamzaMusa N. Hamza
Musa N. Hamza
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Slawomir KozielSlawomir Koziel
Slawomir Koziel
MHMuhamad A. Hamad
Muhamad A. Hamad
IDIftikhar Ud ud Din
Iftikhar Ud ud Din
Mohammad AlibakhshikenariMohammad Alibakhshikenari
Mohammad Alibakhshikenari
non-melanoma skin cancer (NMSC) is among the most prevalent forms of cancer originating in the top layer of the skin, with basal cell carcinoma (BCC) and squamous cell carcinoma (SCC) being its primary categories. While both types are highly treatable, the success of treatment hinges on early diagnosis. Early-stage NMSC detection can be achieved through clinical examination, typically involving visual inspection. An alternative, albeit invasive, method is a skin biopsy. Microwave imaging has gained prominence for non-invasive early detection of various cancers, leveraging distinct dielectric properties of healthy and malignant tissues to discriminate tumors and categorize them as benign or malignant. Recent studies demonstrate the potential of terahertz (THz) spectroscopy for detecting biomarkers by aligning electromagnetic wave frequencies in the low THz range (0.1 to 10 THz) with resonant frequencies of biomolecules, such as proteins. This study proposes an innovative microscale biosensor designed to operate in the THz range for the high-sensitivity and efficient diagnosis of non-melanoma skin cancer. By incorporating meticulously designed metamaterial layers, the sensor's absorption properties can be controlled, a critical aspect for discriminating between normal and NMSC-affected skin. In particular, the interaction between skin and THz waves, influenced by dielectric properties and unique vibrational resonances of molecules within tissue, is crucial for wave propagation and scattering. Extensive numerical studies showcased the suitability of the proposed biosensor for NMSC diagnosis, illustrated through specific case studies. These findings hold the potential to pave the way for further development of non-invasive microwave-imaging-based techniques for detecting NMSC and other types of skin cancer.

7 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
IDIftikhar Ud ud Din
Iftikhar Ud ud Din
Mohammad AlibakhshikenariMohammad Alibakhshikenari
Mohammad Alibakhshikenari
Bal VirdeeBal Virdee
Bal Virdee
RJRenu Karthick Rajaguru Jayanthi
Renu Karthick Rajaguru Jayanthi
Sadiq UllahSadiq Ullah
Sadiq Ullah
Slawomir KozielSlawomir Koziel
Slawomir Koziel
In this paper, a radiating element consisting of a modified circular patch is proposed for MIMO arrays for 5G millimeter-wave applications. The radiating elements in the proposed 2 × 2 MIMO antenna array are orthogonally configured relative to each other to mitigate mutual coupling that would otherwise degrade the performance of the MIMO system. The MIMO array was fabricated on Rogers RT/Duroid high-frequency substrate with a dielectric constant of 2.2, a thickness of 0.8 mm, and a loss tangent of 0.0009. The individual antenna in the array has a measured impedance bandwidth of 1.6 GHz from 27.25 to 28.85 GHz for S11 ≤ −10 dB, and the MIMO array has a gain of 7.2 dBi at 28 GHz with inter radiator isolation greater than 26 dB. The gain of the MIMO array was increased by introducing frequency-selective surface (FSS) consisting of 7 × 7 array of unit cells comprising rectangular C-shaped resonators, with one embedded inside the other with a central crisscross slotted patch. With the FSS, the gain of the MIMO array increased to 8.6 dBi at 28 GHz. The radiation from the array is directional and perpendicular to the plain of the MIMO array. Owing to the low coupling between the radiating elements in the MIMO array, its Envelope Correlation Coefficient (ECC) is less than 0.002, and its diversity gain (DG) is better than 9.99 dB in the 5G operating band centered at 28 GHz between 26.5 GHz and 29.5 GHz.

11 September 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
Musa N. HamzaMusa N. Hamza
Musa N. Hamza
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
SLSunil Prabhatbhai Lavadiya
Sunil Prabhatbhai Lavadiya
IDIftikhar Ud ud Din
Iftikhar Ud ud Din
BSBruno Cavalcante de Souza Sanches
Bruno Cavalcante de Souza Sanches
SIShabiul Islam
Shabiul Islam
This research introduces an innovative design for a metamaterial-based compact multi-band biosensor aimed at early-stage cervical cancer detection. The device operates within the terahertz (THz) frequency range, specifically from zero to six THz. The proposed sensor architecture features a metamaterial layer composed of a patterned aluminum structure deposited on a polyimide substrate. The primary design objective is to optimize the geometry parameters to achieve near-perfect absorption of electromagnetic waves across the entire operating bandwidth. The design process utilizes full-wave electromagnetic simulation tools. The paper details all intermediate steps in the sensor’s topology development, guided by an investigation of the absorption characteristics of successive architectural variations. It also analyzes the effects of the substrate and resonator material. The suitability of the proposed sensor for early-stage cancer diagnosis is demonstrated using a microwave imaging (MWI) system that incorporates the device. Extensive simulation studies confirm the sensor’s capability to distinguish between healthy and cancerous cervical tissue. For further validation, comprehensive benchmarking is conducted against numerous state-of-the-art sensor designs reported in recent literature. These comparative studies indicate that the proposed sensor offers superior performance in terms of absorbance levels and the width of the operating bandwidth, both of which enhance the sensitivity of cancer detection.

3 March 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Musa N. HamzaMusa N. Hamza
Musa N. Hamza
Mohammad AlibakhshikenariMohammad Alibakhshikenari
Mohammad Alibakhshikenari
Bal VirdeeBal Virdee
Bal Virdee
SLSunil Prabhatbhai Lavadiya
Sunil Prabhatbhai Lavadiya
IDIftikhar Ud ud Din
Iftikhar Ud ud Din
MSMilad Shariatifar
Milad Shariatifar
Cancer remains one of the leading causes of mortality worldwide, with breast cancer being a particularly prevalent form. Projections estimate nearly 20 million new cases globally over the next two decades. Early detection is critical for effective treatment; however, conventional diagnostic techniques often lack the necessary sensitivity and specificity, with some methods being invasive and labor-intensive. Recent advancements in microwave imaging (MWI) have shown significant potential as efficient, non-invasive tools for monitoring various cancer types. MWI operating in the terahertz (THz) range has emerged as a promising approach for bio-sensing, offering the precision needed to differentiate between healthy and cancerous tissues by analyzing small-scale biological features. Among the methods for breast cancer detection, the identification and analysis of MCF-7 breast cancer cells are particularly significant. THz waves interact uniquely with the intrinsic properties of MCF-7 cells, making THz-based biosensors ideal candidates for diagnostic tools. However, many existing sensors are limited in key performance areas, including operating bandwidth and absorption efficiency. This study introduces a novel multi-band metamaterial (MTM)-based biosensor specifically designed for the detection of MCF-7 breast cancer cells. The sensor features a compact geometry composed of multiple resonators made from 200-nm-thick aluminum (Al) layers on a 50-μm-thick polyethylene terephthalate (PET) substrate. With dimensions of only 198 × 198 μm², the proposed device is exceptionally compact. It operates in the 0.5 THz to 1.6 THz frequency range and achieves near-perfect absorption rates (>99%) across multiple bandwidths. These results are achieved through precise tuning of the sensor's geometry and architectural optimization, significantly enhancing its sensitivity for cancer detection. Comprehensive validation of the sensor is performed using full-wave electromagnetic analysis, which includes evaluating electric and magnetic field distributions, surface currents, and scattering parameters. Extensive benchmarking demonstrates the device’s superior performance compared to state-of-the-art biosensors, excelling in metrics such as quality-factor, figure of merit (FOM), and absorption efficiency. Additionally, the proposed sensor has been integrated into an MWI system to evaluate its practical application. The device successfully discriminated against subtle changes in the refractive index of biological tissues, confirming its ability to detect MCF-7 cells effectively. These findings highlight the sensor's suitability as a non-invasive, early-stage diagnostic tool for breast cancer.

31 March 2023 in Journal of Electromagnetic Engineering and Science
Verified
Journal Article
Open access
PDF file
IDIftikhar Ud ud Din
Iftikhar Ud ud Din
WUWaheed Ullah
Waheed Ullah
NANisar Ahmad Abbasi
Nisar Ahmad Abbasi
SUSadiq Ullah
Sadiq Ullah
WSWaleed Shihzad
Waleed Shihzad
DJDushantha Nalin K. Jayakody
Dushantha Nalin K. Jayakody
This article presents a compact ultra-wideband (UWB) circular monopole antenna with a frequency-selective surface (FSS) for gain enhancement. The proposed antenna has a circular patch with circular cuts at the edges and is excited by a microstrip feed. The bottom plane is truncated and further modified by two triangular cuts at the sides and one rectangular cut in the middle to improve the radiation characteristics of the UWB antenna. The antenna is designed on an FR-4 substrate with a thickness of 1.6 mm, a relative permittivity of 4.3, and planner dimensions of 30 mm × 30 mm. To improve the proposed antenna’s gain, an FSS is designed that consists of periodic unit cells of metal printed on the upper layer of an FR-4 substrate with dimensions of 0.11λ × 0.11λ at the lowest operating frequency of 3.3 GHz. The FSS shows a very low transmission coefficient and linearly reducing reflection phase with increasing frequency over a frequency range of 3.3–10.8 GHz. The gain of the proposed antenna is increased from 3 dB to 8.1 dB at 9 GHz by placing the antenna on the FSS. Moreover, the prototype of the proposed antenna is fabricated, and the experimental results are measured, which show close agreements with simulated results. The FSS-based antenna has directional radiation patterns, making it a potential candidate for ground-penetrating radar and UWB applications.

26 April 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
Musa N. HamzaMusa N. Hamza
Musa N. Hamza
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
SLSunil Prabhatbhai Lavadiya
Sunil Prabhatbhai Lavadiya
Slawomir KozielSlawomir Koziel
Slawomir Koziel
IDIftikhar Ud ud Din
Iftikhar Ud ud Din
BSBruno Cavalcante de Souza Sanches
Bruno Cavalcante de Souza Sanches
The purpose of this study is development of a novel high-performance low-Petahertz (PHz) biosensor for non-melanoma skin cancer (NMSC) diagnosis. The presented device is designed to work within a microwave imaging regime, which is a promising alternative to conventional diagnostic methods such as visual examination, dermoscopy, and biopsy. The suggested biosensor incorporates a dual-band perfect absorber (operating bands at 0.909 PHz and 1.215 PHz) constructed using aluminum layers separated by a dielectric material. Numerical studies confirm its suitability for NMSC diagnosis, enabling discrimination between healthy and cancerous skin tissues and precise visualization of affected areas. Compared to existing THz devices, the proposed biosensor offers improved sensitivity, a smaller size, and enhanced resolution, attributed partially to the transition to the petahertz band. Moreover, our research highlights the potential of PHz spectroscopy for biomarker detection, advancing non-invasive microwave imaging techniques for NMSC and other skin cancers. The proposed biosensor boasts higher sensitivity, figure of merit (FOM), and quality factor (Q-factor), while its insensitivity to polarization angle ensures superior signal-to-noise ratio and high-resolution imaging, instilling confidence in specialists.