Yi Yang

Dr. Yi Yang


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
YYYi Yang
Yi Yang
SYShuo Yin
Shuo Yin
YLYongxin Li
Yongxin Li
DLDan Lu
Dan Lu
JZJing Zhang
Jing Zhang
CSChengjun Sun
Chengjun Sun

26 February 2021 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
YYYi Yang
Yi Yang
JZJing Zhang
Jing Zhang
YLYongxin Li
Yongxin Li
SYShuo Yin
Shuo Yin
YJYang Jiang
Yang Jiang
CSChengjun Sun
Chengjun Sun
A dissolvable layered double hydroxide-based solid-phase extraction combined with high-performance liquid chromatography was developed for the analysis of minocycline, oxytetracycline, tetracycline, demeclocycline, metacycline, chlortetracycline and doxycycline in milk samples. In situ formation of the layered double hydroxide was achieved by the addition of MgCl2–AlCl3 solution to alkaline deproteinized milk. The analytes were efficiently extracted by the Mg/Al layered double hydroxide. After centrifugation, the co-precipitates were dissolved in 0.1 mol L−1 Na2EDTA–McIlvaine buffer prior to HPLC analysis. Under optimized conditions, the method achieved low detection limits of 0.414–0.986 μg L−1 and quantification limits of 1.38–3.29 μg L−1, and good recoveries of 93.5–100% with intra- and inter-day RSDs of 0.498–4.08% and 1.23–10.0%, respectively. This method is convenient, accurate, sensitive, rapid, cost-effective, eco-friendly, and suitable for the determination of seven tetracycline antibiotics in milk samples.

22 December 2014 in Current Pharmaceutical Analysis
Verified
Journal Article
Closed access
PDF file
DLDan Lu
Dan Lu
YYYi Yang
Yi Yang
YLYongxin Li
Yongxin Li
CSChengjun Sun
Chengjun Sun
Vitamin E (VE) is one category of important fat-soluble vitamins for human normal growth, which consists of eight isomers known as α-, β-, γ- and δ-tocopherol and α-, β-, γ- and δ-tocotrienol. Each of the isomers has unique and potent physiological functions, thus it is important to analyze VE isomers respectively. This review briefly introduces physiological functions of tocopherols and tocotrienols, and presents the progress of sample pretreatment and analysis of these compounds in pharmaceuticals and foods in the last decade, then makes a comparison in the aspects of sensitivity, selectivity and simplicity of the various analytical methods. Due to their high efficiency, speedness, inexpensiveness and environmental friendliness, nano-LC and capillary electrophoresis including non-aqueous capillary electrophoresis (NACE), capillary electrochromatography (CEC) and microemulsion electrokinetic chromatography (MEEKC) have been applied in the analysis of VE family, which will also be discussed in this review.

3 March 2015 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
DLDan Lu
Dan Lu
YYYi Yang
Yi Yang
XWXin Wu
Xin Wu
LZLi Zeng
Li Zeng
YLYongxin Li
Yongxin Li
CSChengjun Sun
Chengjun Sun
A rapid and efficient gas chromatography-mass spectrometry (GC-MS) has been developed for determination of eight VE isomers including α-, β-, γ-, δ-tocopherols and tocotrienols, as well as α-tocopherol acetate in functional foods and nutritional supplements. The vitamin E isomers in samples were directly extracted without saponification with mixed solvents of methanol and hexane (7 : 3,v/v). Good separation was achieved using a VF-5MS column (30 m × 0.25 mm, 0.25 μm) within 13 min. The mass spectrometer was operated in both full scan mode and SIM mode using electron impact ionization. Qualitative detection was based on characteristic ion pairs and retention time. Dibenzanthracene was used as an internal standard for quantification measurement. The linear ranges of the method were from 0.1 to 40 μg mL−1 with the correlation coefficients greater than 0.997. The detection limits ranged from 0.09 ng mL−1 to 0.46 ng mL−1, and the quantification limits were from 0.29 ng mL−1 to 1.52 ng mL−1. The intra-day and inter-day relative standard deviations (RSDs) of the method (for 1 μg mL−1 standard solution) were in the range of 4.9% to 8.0% and 2.1% to 4.9%, respectively. The average recoveries of the method ranged from 83.2% to 107%, with the RSDs from 1.1% to 8.4%. The method has been applied for the determination of VE isomers and α-tocopherol acetate in functional foods and nutritional supplements with satisfactory results.

17 June 2024 in LWT
Verified
Journal Article
Open access
YWYuanyi Wu
Yuanyi Wu
YXYumei Xiao
Yumei Xiao
YJYang Ju
Yang Ju
YSYanque Sun
Yanque Sun
JHJialin He
Jialin He
YYYi Yang
Yi Yang

9 July 2024 in Analytica Chimica Acta
Verified
Journal Article
Closed access
JLJing Liu
Jing Liu
CZCongping Zhao
Congping Zhao
JYJun Yang
Jun Yang
YZYan Zhou
Yan Zhou
HDHaiyang Du
Haiyang Du
YYYan Yang
Yan Yang