Clara Pogner

Mrs. Clara Pogner

Bioresources, AIT - Austrian Institute of Technology, Vienna, Wien, Austria
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2024 in Science of The Total Environment
Verified
Journal Article
Open access
CPClara Pogner
Clara Pogner
CAC. Antunes
C. Antunes
GAG.P. Apangu
G.P. Apangu
NBN. Bruffaerts
N. Bruffaerts
SCS. Celenk
S. Celenk
CSC. Ambelas Skjøth
C. Ambelas Skjøth
Bioaerosol is composed of different particles, originating from organisms, or their fragments with different origin, shape, and size. Sampling, analysing, identification and describing this airborne diversity has been carried out for over 100 years, and more recently the use of molecular genetic tools has been implemented. However, up to now there are no established protocols or standards for detecting airborne diversity of bacteria, fungi, viruses, pollen, and plant particles. In this review we evaluated commonalities of methods used in molecular genetic based studies in the last 23 years, to give an overview of applicable methods as well as knowledge gaps in diversity assessment. Various sampling techniques show different levels of effectiveness in detecting airborne particles based on their DNA. The storage and processing of samples, as well as DNA processing, influences the outcome of sampling campaigns. Moreover, the decisions on barcode selection, method of analysis, reference database as well as negative and positive controls may severely impact the results obtained. To date, the chain of decisions, methodological biases and error propagation have hindered DNA based molecular sequencing from offering a holistic picture of the airborne biodiversity. Reviewing the available studies, revealed a great diversity in used methodology and many publications didn't state all used methods in detail, making comparisons with other studies difficult or impossible. To overcome these limitations and ensure genuine comparability across studies, it is crucial to standardize protocols. Publications need to include all necessary information to enable comparison among different studies and to evaluate how methodological choices can impacts the results. Besides standardization, implementing of automatic tools and combining of different analytical techniques, such as real-time evaluation combined with sampling and molecular genetic analysis, could assist in achieving the goal of accurately assessing the actual airborne biodiversity.

6 September 2018 in Environmental Science: Processes & Impacts
Verified
Journal Article
Closed access
PDF file
VUVerena Unterwurzacher
Verena Unterwurzacher
CPClara Pogner
Clara Pogner
HBHarald Berger
Harald Berger
JSJoseph Strauss
Joseph Strauss
SSSabine Strauss-Goller
Sabine Strauss-Goller
MGMarkus Gorfer
Markus Gorfer
Determination and assessment of airborne fungal particles is complex and results of different sampling and analytical strategies are hard to compare due to limitations of each of the techniques. Here, an indoor mold detection system based on quantitative polymerase chain reaction (qPCR) is described and validated for its reliability and stability to identify airborne fungal particles collected. Data obtained from testing the system with fungal DNA, spore suspensions and bioaerosols indicated a need for spiking and normalization of measurements due to material loss and assay specific bias. Considering the loss of material during sample processing, detection limits defined for suspensions of Tritirachium oryzae spores were roughly 18 spores per sample. Detection of fungal spore mixtures nebulized under controlled conditions in a bioaerosol chamber showed generally 2–3 times higher normalized values measured with the molecular system compared to cultivation. Data obtained from a mold infested indoor sampling site and its corresponding outdoor reference measurement showed good correlations between qPCR and high-throughput sequencing (rho = 0.83, p < 0.01), if Cladosporium species were excluded. Taking necessary data normalization into account, the described qPCR detection system shows great potential to complement commonly used culture based approaches with the aim to improve the precision of indoor mold assessments. In contrast to already available qPCR assays that detect certain molds on a species level, this system covers a broad range of relevant fungal communities, serving as a promising alternative to high-throughput sequencing to identify indoor molds.

1 July 2021 in Aerosol Science and Engineering
Verified
Journal Article
Open access
PDF file
VUVerena Unterwurzacher
Verena Unterwurzacher
SBStephan Bruck
Stephan Bruck
MBMax Biedermann
Max Biedermann
CPClara Pogner
Clara Pogner
AKAnja Konlechner
Anja Konlechner
SSSabine Strauss-Goller
Sabine Strauss-Goller
Although numerous bioaerosol samplers for counting and identifying airborne microorganisms are available, the considerably high purchase and maintenance costs for the sampler often prevent broad monitoring campaigns for occupational or environmental surveillance of bioaerosols. We present here a newly developed simple adapter and filter system (TOP filter system) designed to collect bioaerosol particles from a defined air volume using conventional vacuum cleaners as air pumps. We characterized the physical properties of the system using air flow measurements and validated the biological performance. The culture-based detection capacities for airborne fungal species were compared to a standard impaction sampler (MAS-100 NT) under controlled conditions in a bioaerosol chamber (using Trichoderma spores as the test organism) as well as in the field. In the chamber, an overall equivalent detection capacity between all tested filters was recorded, although a significant underrepresentation of the TOP filter system for Trichoderma spores were seen in comparison to the MAS-100 NT. In a comparative field study (n = 345), the system showed similar biological sampling efficiencies compared to the MAS-100 NT impactor, only the diversity of identified fungal communities was slightly lower on the filters. Thus, the system is suitable for large-scale environmental sampling operations where many samples have to be taken in parallel at a given time at distant locations. This system would allow endeavors such as antibiotics resistance monitoring or hygiene surveys in agricultural or occupational settings.

24 January 2019 in Aerosol Science and Technology
Verified
Journal Article
Closed access
CPClara Pogner
Clara Pogner
AKAnja Konlechner
Anja Konlechner
VUVerena Unterwurzacher
Verena Unterwurzacher
AKAnnette Kolk
Annette Kolk
MHManfred Hinker
Manfred Hinker
SSSabine Strauss-Goller
Sabine Strauss-Goller
In this work, we describe a novel type of bioaerosol test system based on a laminar airflow chamber that provides a homogenous aerosol of microbial cells with known concentrations and defined culturability to bioaerosol samplers positioned in the chamber. In the system, three control and monitoring points (CMPs) are implemented in which the number and culturability of microbes can be determined by combining optical particle counting with microscopic and culture-based microbiological analyses. This lineup is designed to quantify the biological sampling efficiency (BSE) of a bioaerosol sampling device. Seven bioaerosol samplers were tested with four fungal and one bacterial species and their BSEs have been determined under optimized standard operating conditions. After executing tests with the appropriate statistical power, this new laminar-flow platform demonstrated the sensitivity necessary to determine significant differences in the recovery efficiency of viable fungal spores and bacterial cells in modern samplers. Under these test conditions, the samplers showed considerable differences in BSEs for the individual fungal and bacterial species. Our data demonstrate that a large number of experimental repetitions and measurements under tightly controlled and monitored conditions are necessary to quantify the BSE of a given sampler and to compare them to each other. Employing this system improves biological evaluation of samplers because natural environments are not suitable for this task due to their high variabilities in homogeneity and distribution of cells as well as fluctuations in culturability ratios. © 2019 American Association for Aerosol Research

Verified
Journal Article
Open access
PDF file
AFAila Fakhimahmadi
Aila Fakhimahmadi
IHIlir Hasanaj
Ilir Hasanaj
GHGerlinde Hofstetter
Gerlinde Hofstetter
CPClara Pogner
Clara Pogner
MGMarkus Gorfer
Markus Gorfer
Franziska Roth-WalterFranziska Roth-Walter
Franziska Roth-Walter
Alternaria alternata is a common fungus strongly related with severe allergic asthma, with 80% of affected individuals being sensitized solely to its major allergen Alt a 1. Here, we assessed the function of Alt a 1 as an innate defense protein binding to micronutrients, such as iron–quercetin complexes (FeQ2), and its impact on antigen presentation in vitro. Binding of Alt a 1 to FeQ2 was determined in docking calculations. Recombinant Alt a 1 was generated, and binding ability, as well as secondary and quaternary structure, assessed by UV-VIS, CD, and DLS spectroscopy. Proteolytic functions were determined by casein and gelatine zymography. Uptake of empty apo– or ligand-filled holoAlt a 1 were assessed in human monocytic THP1 cells under the presence of dynamin and clathrin-inhibitors, activation of the Arylhydrocarbon receptor (AhR) using the human reporter cellline AZ-AHR. Human PBMCs were stimulated and assessed for phenotypic changes in monocytes by flow cytometry. Alt a 1 bound strongly to FeQ2 as a tetramer with calculated Kd values reaching pico-molar levels and surpassing affinities to quercetin alone by a factor of 5000 for the tetramer. apoAlt a 1 but not holoAlta 1 showed low enzymatic activity against casein as a hexamer and gelatin as a trimer. Uptake of apo– and holo–Alt a 1 occurred partly clathrin-dependent, with apoAlt a 1 decreasing labile iron in THP1 cells and holoAlt a 1 facilitating quercetin-dependent AhR activation. In human PBMCs uptake of holoAlt a 1 but not apoAlt a 1 significantly decreased the surface expression of the costimulatory CD86, but also of HLADR, thereby reducing effective antigen presentation. We show here for the first time that the presence of nutritional iron complexes, such as FeQ2, significantly alters the function of Alt a 1 and dampens the human immune response, thereby supporting the notion that Alt a 1 only becomes immunogenic under nutritional deprivation.

20 August 2025 in Applied and Environmental Microbiology
Verified
Journal Article
Open access
CPClara Pogner
Clara Pogner
MGMarkus Gorfer
Markus Gorfer
MRM. Raulf
M. Raulf
JSJoseph Strauss
Joseph Strauss
ISI. Sander
I. Sander
Airborne fungal spores are recognized for their human health impact, yet dose-response relationships remain undefined despite decades of bioaerosol sampling and analysis. In this article, we quantify immunologically active compounds, using six fungal-specific enzyme-linked immunosorbent assays (ELISAs) and compare them with cultivation, spore counting, and quantitative PCR (qPCR), using identical filter extract aliquots, various concentrations, single-organism aerosols, and mixes, in a controlled environment. Results showed high agreement between ELISAs and spore counting. By contrast, CFU enumeration and qPCR showed lower correlation with the other methods. Results of ELISAs showed high reproducibility of technical replicates and sampling duplicates, whereas CFU and qPCR results had high deviations. ELISA detection limits ranged from 10 to 100 spores/mL for larger spores ( Cladosporium herbarum , Aspergillus amstelodami ) and from 103 to 104 spores/mL for smaller spores ( Aspergillus amoenus , Aspergillus fumigatus , Penicillium chrysogenum ). The Wallemia sebi and the Penicillium chrysogenum ELISAs cross-reacted to Aspergillus protuberus or Aspergillus amstelodami , respectively. The spore dust production method influenced the spore germination rate and qPCR results significantly. By contrast, ELISA results remain unchanged, with the exception of the W. sebi ELISA. Quantitative spore counting was challenged by mixtures of species with morphologically similar spores from different fungal groups. In conclusion, the ELISA method is found suitable for fungal antigen quantification of air samples, provided the assays are sufficiently sensitive and specific, and germination evaluation is not required for risk assessment, leading to C. herbarum and A. amstelodami ELISA recommendations. IMPORTANCE: Bioaerosol detection and analysis is an ongoing field of research. Although various methodologies are used for collection and analysis, there is no single method available to close the knowledge gap between exposure and health impact. For airborne fungal material, the standard analysis method remains cultivation. With molecular technology advancing in the field, both methods can only show the exposure to living, cultivatable, or total fungal cells in the airborne environment. To close the gap between airborne concentrations and impact on the human body, recognition of the allergenic potential is necessary. Therefore, we evaluated six fungal-specific ELISAs to make them ready for application in field studies and compared them to cultivation, spore counting, and molecular genetic methods. We are confident that in the future antigen-recognizing methods like the tested ELISAs will enable moving from particle detection toward detection of the disease-causing agent.