In this article, load-independent constant current/voltage control operations of an LCC -Series compensated wireless electrical vehicle (EV) chargers are presented. The parameters of the LCC -Series compensation topology are designed based on load-independent zero phase angle and soft switching operation in the constant current charging operation. Then, the load independent soft switching conditions are achieved for constant voltage charging operation with a semibridgeless active rectifier using pulse density modulation control. Thus, high efficiency power transfer to the load is performed during the entire charging period. The wireless communication is not needed to achieve the output voltage regulation in the proposed EV charging system. The soft switching operations of the switches on the primary and the secondary side are achieved in a wide load range. The performance of the proposed charging system is validated by a prototype. At the full load condition, the output voltage of the system is regulated at 210 V while the output current is 5 A. The maximum efficiency is measured 93.8% at 1 kW output power with 150 mm air gap. The efficiency performance of the system is also evaluated based on the misalignment conditions.
15 December 2021 in IEEE Transactions on Industrial Electronics
In this article, an improved pulse density modulation (PDM) control for secondary side controlled wireless power transfer (WPT) system is proposed. The LCC-S network is selected for the compensation of the reactive power in the system. In the secondary side, an active rectifier with improved PDM control is used to regulate the output voltage. The output voltage regulation is achieved by changing the pulse density of the rectifier switches. By using the proposed PDM pattern, the input pulse sequence of the active rectifier can be distributed more homogenously compared to the conventional PDM control. Therefore, the output current ripple of the primary side inverter and the output voltage ripple of the active rectifier are reduced. The light load efficiency is also improved compared to conventional PDM control. The soft switching conditions are achieved for inverter and active rectifier switches. The experimental prototype with 150 mm air gap is built to validate the performance of the proposed system. The overall efficiency of the system with the proposed PDM is improved by 1.7% and 9.9% compared to the conventional irregular and regular PDM control, respectively. The output voltage ripple of the active rectifier and the output current ripple of the primary inverter are also reduced at light load conditions with the proposed PDM.
This article presents an LCC-LCC wireless power transfer (WPT) system based on dual side variable inductor (VI) control to achieve high efficiency and output power regulation. By adjusting the inductances of the VIs, the output voltage and current can be controlled while the wide range of zero voltage switching (ZVS) can be achieved for the primary side inverter under different misalignment conditions. The VIs in the primary and secondary sides provides ZVS condition and output regulation against misalignment, respectively. Since the resonant inductors of LCC-LCC topology are designed as VIs, the use of additional compensation elements is also eliminated. Moreover, the wireless communication is not necessary between primary and secondary side. A 300 W prototype is developed to verify the effectiveness of the proposed control method. Experimental results demonstrate that good regulation performance and high transmission efficiency are provided for the WPT system under the wide range of misalignment. A maximum efficiency of 92.5 % has been achieved for the proposed WPT system under the full power output.
30 September 2024 in Gazi University Journal of Science Part A: Engineering and Innovation
This paper presents a novel control method that integrates super-twisting sliding mode (STSM) voltage control with proportional-integral (PI) current control for a four-phase interleaved boost converter (IBC) in fuel cell applications. The STSM control, employed in the outer voltage loop, provides robust voltage regulation by generating precise reference currents for each phase. The conventional PI control in the inner current loop utilizes these reference currents to generate pulse width modulation (PWM) signals for each phase. The effectiveness of the proposed control strategy is evaluated through comprehensive simulation studies in MATLAB/Simulink, demonstrating an improvement in dynamic performance and enhanced robustness compared to conventional methods. Quantitative analysis shows that the output voltage quickly rises to the reference voltage within approximately 0.25 seconds in the proposed STSM-PI control method and improves transient response by 16 times compared to the conventional PI-PI method. This integrated STSM-PI control strategy offers significant advancements in reliability and efficiency making it a promising solution for high-performance fuel cell power systems.
For electric vehicle (EV) battery chargers, inductive power transfer (IPT) has become popular day by day due to its features such as being safe, comfortable and weather proof. The constant current (CC) and the constant voltage (CV) charge control modes are important for high-efficiency charging and long-life use of Lithium-ion (Li-ion) batteries commonly used in EVs. However, IPT method requires a wide range of operating frequency in order to provide CC/CV charge control modes. In IPT applications, CC and CV charge control modes are mainly achieved with dc-dc circuits using compensation networks at the transmitter and receiver sides. In this study, performances of inductor-capacitor/series compensation and double-sided inductor-capacitor-capacitor compensation topologies are evaluated based on CC/CV charge control modes. The analytical evaluation is presented in terms of voltage and current regulations during the entire charge control period. Finally, presented analytical evaluation is confirmed with ANSYS software providing field-electric common simulation to predict real response of compensation topologies. In the simulation work, both compensation topologies are operated for the maximum 2.5 kW output power and at the 250 V-450 V output voltage range.