Samarjeet Satapathy

Dr. Samarjeet Satapathy

Electrical engineering, Siksha O Anusandhan University, Bhubaneswar, India
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2022 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
NNNarayan Nahak
Narayan Nahak
SSSamarjeet Satapathy
Samarjeet Satapathy
Subject to increasing penetrations of renewable sources like solar photovoltaic (SPV) and wind energy sources, power system oscillation damping is going to be a critical challenge for system operators. This work proposes a new dual compensated governor (DCG) in coordination with a power system stabilizer (PSS) of a pumped storage hydro plant for power oscillation damping subject to intermittent SPV and wind penetration for a hydro, wind, and SPV integrated power system. The phase lag provided by the hydro governor is compensated by additional phase lead contributed by the dual compensation, where speed and real power deviations brought by uncertain SPV and wind penetrations are simultaneously controlled by two lead-lag controllers before being applied to conventional Proportional-Integral-Derivative (PID) governor. Again, subject to critical oscillatory unstable conditions, the DCG is coordinated with PSS through a multiobjective function employing a new modified Differential Evolutionary-Particle swarm optimization (MDEPSO) algorithm. Different case studies with sudden and random SPV and wind penetrations being executed with the proposed controller considering a two area four machine and 39 bus multimachine system with pumped storage hydro units to observe system oscillations are considered. The proposed damping control action has been implemented to damp these oscillations, and the damped response has been analyzed with eigenvalue distributions and Bode plots with sensitivity analysis. The proposed action is found to be much more efficient in contrast to conventional PID governor and PSS damping action. Also, the usage of present hydro governors can be much improved by this coordinated controller action.

8 October 2021
Verified
Conference Paper
Closed access
SSSamarjeet Satapathy
Samarjeet Satapathy
NNNarayan Nahak
Narayan Nahak
APAkshaya Patra
Akshaya Patra
RARamachandra Agrawal
Ramachandra Agrawal
AMAlok Mishra
Alok Mishra
This work present fractional power system stabilizer (FPSS) to damp low frequency oscillations in power system with varying solar penetration FPSS provides additional damping torque in rotor through excitation system of generator for damping action. The power system is subjected to varying SPV generations and eigen analysis with time domain stimulations being carried out to justify the control action. FPSS gains are tuned by squirrel search Algorithm (SAA) techniques, and compared with PSO and DE techniques. The low frequency oscillations resulting from different SPV penetrations are executed with step and random solar power variations proposed fractions PSS Action has been implemented with ITAE based minimization objective function by DE, PSO and SSA algorithm. It is observed that proposed SSA optimized FPSS action can stabilize oscillations much better than other techniques pertained to variations in solar PV generations.

16 December 2021
Verified
Book Chapter
Closed access
PDF file
SSSamarjeet Satapathy
Samarjeet Satapathy
APArjit Gourav Patel
Arjit Gourav Patel
BSBighnesh Samal
Bighnesh Samal
NNNarayan Nahak
Narayan Nahak
PNPravati Nayak
Pravati Nayak

5 May 2025 in IEEE Access
Verified
Journal Article
Open access
SSSamarjeet Satapathy
Samarjeet Satapathy
NNNarayan Nahak
Narayan Nahak
RSRenu Sharma
Renu Sharma
Hydro power generation is one of the most viable renewable sources to meet future energy demand and being a synchronous source, it has also the capability to enhance power system stability. Low frequency oscillations in power grid poses several challenges to operators and need to be damped at earlier stage to maintain stability of power system. The hydro turbine governors usually impart negative damping to these oscillations. So, there can be modification in governor control action to impart damping of these oscillations. In present work the hydro governors are phase compensated and coordinated with dual static synchronous compensator (STATCOM) so as to provide sufficient damping torque. A state space model of dual STATCOM with compensated hydro governor has been developed. Sudden change in reference voltage, uncertain solar and wind penetrations with plug-in electric vehicle as load being considered with different experimentations to impart critical oscillations in power system and proposed controller has been employed to damp these oscillations. Multimachine two area four hydro generators, 39 bus systems with 10 generators and modified IEEE 68 bus system with sixteen generators at different operating conditions have been investigated with proposed controller for oscillation damping. A new multi-objective mean Differential Evolution with time varying accelerated Particle Swarm Optimization algorithm (MeDETVAPSO) has been implemented to tune controller parameters. The proposed controller shows less values of settling time, oscillations peak value and imparting high damping ratio. Settling time, oscillations peak value and minimum damping ratio with proposed controller have been observed as 1.638s, 0.000375pu and 0.987 respectively. These experimentations have been conducted in MATLAB Simulink and verified with real time simulation based in OPAL-RT 4510. The damping capability of proposed controller has been found to be better in contrast to power system stabilizer (PSS), compensated hydro governor, dual STATCOM and performance of MeDETVAPSO has been observed to be better than PSO and DE to tune controller parameters.

21 July 2022
Verified
Conference Paper
Closed access
NNNarayan Nahak
Narayan Nahak
RSRajeev Kumar Singh
Rajeev Kumar Singh
SPSubrat Parida
Subrat Parida
SSSamarjeet Satapathy
Samarjeet Satapathy
PNPravati Nayak
Pravati Nayak
This work proposes an optimal fractional power system stabilizer control action to improve dynamic stability of grid integrated micro grid system. A fractional PID controller-based PSS has been implemented here whose gains are optimized by sailfish algorithm. The solar and wind generations in the micro grid are varied in step and random manner creating disturbances which is variation in angular frequency of power system. By proposed sailfish algorithm tuned PSS action this variation in angular frequency is heavily damped that has been compared with PSO & DE algorithms. System Eigen analysis has been performed to validate proposed optimal control action. The system eigen distributions and results analysis predict that proposed action is more efficient and is simple to implement for a micro grid system.

4 July 2022 in Journal of Information and Optimization Sciences
Verified
Journal Article
Closed access
SSSamarjeet Satapathy
Samarjeet Satapathy
NNNarayan Nahak
Narayan Nahak
JPJyotiranjan Parida
Jyotiranjan Parida
Memetic salp swarm algorithm (MSSA) is proposed in the present work to optimally set the gains of fractional power system stabilizer (FPSS) for damping angular speed variation in power system. The optimization is based on the objective of minimizing variation in rotor angular frequency subject to disturbance which is change in reference voltage applied to generator. A single generator system connected with infinite bus has been experimented in this work for sudden and random variations in reference voltage applied to generator. The power system stabilizer (PSS) is based on fractional lead-lag control actions and MSSA is employed to tune the controller gains. Eigen values are analyzed with proposed control and MSSA has been compared with PSO (Particle swarm optimization) and salp swarm algorithm (SSA). It is observed from system response that MSSA can effectively tune the PSS parameters for oscillation damping subject to critical disturbances like random reference voltage variations.