Arjun Sunil Rao

Dr. Arjun Sunil Rao

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
ABAbhishek B.
Abhishek B.
JAJayarama A.
Jayarama A.
ARArjun Sunil Rao
Arjun Sunil Rao
SNSanjog S. Nagarkar
Sanjog S. Nagarkar
ADArnab Dutta
Arnab Dutta
RPRichard Pinto
Richard Pinto

28 May 2019 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
ARArjun Sunil Rao
Arjun Sunil Rao
KRK R Rashmi
K R Rashmi
DMD V Manjunatha
D V Manjunatha
JAJayarama A.
Jayarama A.
RPRichard Pinto
Richard Pinto
This work presents design, fabrication and optimization of methanol concentration and flow channel cross-sectional geometry for enhanced power output in passive micro-direct methanol fuel cells. Passive micro-direct methanol fuel cells are fabricated with flow channels in silicon having both rectangular and trapezoidal cross-sectional geometry for flow of methanol at anode and air at cathode using microelectromechanical systems (MEMS) fabrication technique. The experiments are conducted at 25 °C by feeding methanol with a flow rate of 25 μ l min −1 and supply of air at cathode by air-breathing method. Results show a peak in open circuit voltage and power density at 7 M methanol concentration for passive micro-direct methanol fuel cells having both rectangular and trapezoidal cross-sectional geometry. A study of influence of silicon flow channel cross-sectional geometry on passive micro-direct methanol fuel cell performance shows for the first time that the flow channels with trapezoidal cross-section enhance the power density (6.64 mW cm −2 ) nearly by a factor of two compared to that of flow channels with rectangular cross-section (3.9 mW cm −2 ) at 7 M methanol concentration. We believe that, though our results of significant enhancement of power density with trapezoidal fuel flow channels are obtained with micro-direct methanol fuel cells as a platform, they should also be applicable to other proton exchange membrane fuel cells with ethanol or humidified hydrogen as fuel.

10 May 2019 in Smart Materials and Structures
Verified
Journal Article
Closed access
RRRashmi K R
Rashmi K R
ARArjun Sunil Rao
Arjun Sunil Rao
JAJayarama A
Jayarama A
RPRichard Pinto
Richard Pinto
Low frequency piezoelectric P(VDF-TrFE) micro-cantilever vibration sensors have been developed for the first time with a novel MEMS process. Design and simulation of micro-cantilevers were carried out using COMSOL Multiphysics based on finite element method. Frequencies and device dimensions were determined based on simulation results. The design was implemented on 〈110〉 Si wafer using a specially developed bulk micromachining process. Micro-cantilevers were fabricated with 2.5 μ m thick P(VDF-TrFE) co-polymer film deposited by spin coating technique; electrodes for power output were formed by sequential thermal evaporation of Cr-Au thin films. The two critical process steps used for the suspension of P(VDF-TrFE) micro-cantilevers are: (1) bulk micromachining of silicon from the backside using anisotropic wet etchant TMAH to define the micro-cantilever suspension regions, and (2) CHF 3 /O 2 based plasma etching of SiO 2 from backside for the final release of P(VDF-TrFE) micro-cantilevers. These devices were operated in longitudinal mode with Cr-Au interdigitated electrodes on P(VDF-TrFE) micro-cantilevers for power extraction. The experimental results obtained with laser Doppler vibrometer for micro-cantilevers with 1000 μ m length, 300 μ m width and 2.5 μ m thickness showed resonant frequency 477.03 Hz and power output 187.4 pW for tip displacement 312.5 μ m which are closely in agreement with the simulated values 453.65 Hz and 189 pW for tip displacement 310 μ m, respectively. The volume power density of this P(VDF-TrFE) unimorph micro-cantilever is 249.92 nW mm −3 , which is found to be better compared with other polymer piezoelectric cantilevers.

14 December 2024 in Heliyon
Verified
Journal Article
Open access
NPNandini A. Pattanashetti
Nandini A. Pattanashetti
Mahadevappa KariduraganavarMahadevappa Kariduraganavar
Mahadevappa Kariduraganavar
ARArjun Sunil Rao
Arjun Sunil Rao
ASAmruta Savadi
Amruta Savadi
MPMaruti Pali
Maruti Pali
SSSiddharth Sonavane
Siddharth Sonavane
The selection of a biomaterial plays a very important role for the development of scaffolds for biomedical applications. Amidst, the development of nanofibrous scaffolds through electrospinning technique by selecting a suitable polymer is of more importance. Poly (2-ethyl-2-oxazoline) (PEOX) is one among the selected polymers that can be employed for electrospinning for the development of scaffolds for biomedical applications. PEOX is a water-soluble polymer which is highly desirable for biomedical applications. At the same time, PEOX is soluble in the mixture of organic solvents as well. In view of this, the present study is the preliminary study of using PEOX for the development of scaffolds by using electrospinning technique and to check its potentiality for biomedical application like tissue engineering for the future research. The PEOX scaffolds were fabricated using electrospinning process using water and organic solvents, and the effect of solvent was studied on the morphology and physical properties of the developed scaffolds. The Scanning Electron Microscopic results of the scaffolds showed a uniform nanofibrous structure in case of aqueous PEOX solution, whereas microfibrous structure was obtained for organic solvent. Wettability of the scaffolds was observed by contact angle measurement, which revealed that the hydrophilicity of the PEOX (aq.) scaffold was higher with the contact angle of 55.2° as compared to PEOX (org.) scaffold with the contact angle of 70.38°. Further, the mechanical strength of the scaffolds was calculated in terms of Young's modulus values and it was observed that the PEOX (org.) demonstrated a higher tensile strength of 1.9 MPa compared to PEOX (aq.) scaffold with 1.02 MPa respectively. The results thus clearly conclude that the nature of solvents greatly affect the electrospinning process of PEOX and thereby the properties of the developed PEOX scaffolds based on the solvent. Further, we can say that the developed PEOX scaffolds possess suitable properties to be employed for biomedical applications like tissue engineering.

24 April 2024 in Engineering Research Express
Verified
Journal Article
Open access
VMVijayalaxmi H M
Vijayalaxmi H M
ARArjun Sunil Rao
Arjun Sunil Rao
AKA M Khan
A M Khan
DKDeeksha Kotyan
Deeksha Kotyan
DDDisha D
Disha D
CRChinmayee Rao
Chinmayee Rao
The medical images of people are important and sensitive and cannot be shared with the public considering privacy measures. Maintaining the confidentiality of the medical image is essential, and leakage of such information can cause great loss. Therefore, the information has to be secured while being transferred through a third party, which can be any network medium. Thus, there is a need for developing a robust encryption algorithm. These algorithms improve the security of the ongoing pictures by compromising the nature of the picture and utilizing complex calculations. Algorithms that work on the nature of the picture by utilizing complex cycles, for example, error diffusion, halftoning, wavelet transform, and dithering, lead to time complexity. Thus, a compact and efficient cryptographic algorithm is proposed with fewer mathematical computations that ensure the secured transmission and reception of medical images through the medium using Significant Visual Cryptography (SVC). In SVC, initially, the quality of the secret images (SI) is improved by using the Error Abatement Technique (EAT). The output of EAT is used to generate random share values, which are then implanted in cover pictures. The shares that are transmitted do not reveal the secret information present in the original image because of the steganography features involved in this technique. The integrated check value (ICV) is calculated over the region of interest (ROI) at the encryption and decryption sides to provide additional security. Quality and security analyses have been carried out to ensure the robustness of the algorithm. The detailed study proved that the proposed algorithm beat the constraints of the current calculations. The concept of checking the integrity value and steganography features enhanced the effectiveness of the algorithm.

31 August 2025 in Discover Materials
Verified
Journal Article
Open access
PDF file
BSBasavaraj S. Sannakashappanavar
Basavaraj S. Sannakashappanavar
GVGandham Venkatasubbaiah
Gandham Venkatasubbaiah
JBJ. K. Kasthuri Bha
J. K. Kasthuri Bha
ARArjun Sunil Rao
Arjun Sunil Rao
In this paper, a negative barrier height at the interface of ZnO/Ti was studied using Kelvin probe force microscopy (KPFM) analysis. This result agrees with the metal-semiconductor Ohmic contact theory. Without any dopant, the pure ZnO thin films were deposited over integrated circuit compatible SiO2/p-Si silicon by the radio frequency (RF) sputtering method. Later, the ZnO thin films were annealed at 450 °C in a Nitrogen atmosphere. Annealing of the films produced better-quality contact as measured by a semiconductor parameter analyzer and the surface morphology, crystal structure, and optical properties as analyzed by atomic force microscopy (AFM), X-ray diffraction (XRD), and photoluminescence (PL) spectroscopy. The deposited thin films were analyzed to be crystalline, and edge emission occurred at 365 nm, as confirmed by XRD and PL measurements, respectively. The crystal size of the thin films is measured from XRD and are found to be 15.14 nm. The current-voltage characteristics were used to calculate the barrier height, which proves to be Ohmic in nature because of series resistance and barrier height in homogeneity. The calculated specific resistance of the device is 5 × 10−5 Ω-cm2. This paper would encourage the use of an alternate method to calculate the barrier height of the device.