Youfeng Xu

Youfeng Xu


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2016 in Molecular and Clinical Oncology
Verified
Journal Article
Open access
PDF file
MCMei Chen
Mei Chen
KZKe-Qin Zhang
Ke-Qin Zhang
YXYou-Feng Xu
You-Feng Xu
YXYoufeng Xu
Youfeng Xu
YCYong Cao
Yong Cao
WSWei-Qun Sun
Wei-Qun Sun
The aim of the present study was to evaluate the value of shear wave elastography (SWE) and contrast‑enhanced ultrasonography (CEUS) in the diagnosis of thyroid malignant nodules. A total of 253 patients with 319 thyroid nodules were subjected to two‑dimensional ultrasound (2DUS) and CEUS examinations prior to thyroidectomy between March, 2014 and December, 2015. Young's modulus value for each nodule on 2DUS and CEUS images were recorded. The sensitivity, specificity and accuracy of 2DUS, SWE and CEUS in the diagnosis of thyroid malignant nodules were assessed. The results demonstrated that, of the 319 nodules that were pathologically confirmed, 183 were malignant and 136 were benign. The area under the receiver operating characteristic curve as a result of SWE diagnosis was 0.77. When the threshold of the Young's modulus value was ≥27.65 kPa in the diagnosis of malignant thyroid nodules, SWE exhibited a sensitivity of 84.55% (115/136), a specificity of 84.15% (154/183) and an accuracy of 84.32% (269/319). US contrast imaging of malignant thyroid nodules revealed a major tendency for early hypoenhancement and hypoenhancement. CEUS exhibited a sensitivity of 87.5% (119/136), a specificity of 86.33% (158/183) and an accuracy of 86.83% (277/319) in the diagnosis of malignant thyroid nodules. Compared with 2DUS, SWE, CEUS and their combined use exhibited statistically significant differences in the diagnosis of thyroid malignant nodules in terms of sensitivity, specificity and accuracy (χ2=9.220,15.310 and 40.296, respectively; P=0.000); SWE or CEUS did not differ significantly in the diagnosis of thyroid malignant nodules in terms of sensitivity, specificity or accuracy (χ2=0.737;P=0.542); Compared with the use of SWE or CEUS alone, their combination exhibited statistically significant differences in the diagnosis of malignant thyroid nodules in terms of sensitivity, specificity and accuracy (χ2=12.264 and 6.939, respectively; P=0.000,0.005). In conclusion, the high accuracy of the combined use of SWE and CEUS in the diagnosis of malignant thyroid nodules is of great clinical value.

8 March 2024 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
MCMei Chen
Mei Chen
SLShusheng Liao
Shusheng Liao
YCYong Cao
Yong Cao
MMMeiya Mao
Meiya Mao
XJXiupeng Jia
Xiupeng Jia
YXYoufeng Xu
Youfeng Xu
Objective: Benign Brenner tumor (BBT) is a rare ovarian tumor, and there are few discrete reports about its manifestation in an ultrasound. This study sought to investigate the two-dimensional (2D) and contrast-enhanced ultrasound (CEUS) features of this entity.Methods: This is a retrospective single-center study. The clinical manifestations, laboratory examination, and ultrasound data of 25 female patients with BBT were confirmed by pathology when they underwent 2D and/or CEUS examination at Ningbo First Hospital from January 2012 to June 2023. The ultrasound findings of the patients were analyzed using the terminology of the International Organization for the Analysis of Ovarian Tumor and were read by two senior sonographers who reached an agreement.Results: Among the all 25 patients, most of them were unilateral, and only one patient was bilateral. Thus, 26 lesions were found: 44.0% (11/25) were in the left and 52.0% (13/25) were in the right. Moreover, 53.84% (14/26) were solid lesions, 15.38% (4/26) were mixed lesions, and 26.92% (7/26) were cystic lesions. Among the solid-type patients, 42.85% (6/14) of the cases were with calcification. Upon laboratory examination, 12.0% (3/25) of the patients had high carbohydrate antigen 125 (CA-125) level, and 19.04% (4/21) of the patients had an elevated carbohydrate antigen724 (CA-724) level in the serum tumor markers. In the hormone test, 14.28% (3/21) were found to have a high postmenopausal estrogen level and 14.28%(3/21) were found to have a high level of follicle-stimulating hormone (FSH). One patient with complex manifestations and three with solid manifestations were examined by CEUS to observe the microcirculation perfusion of the tumor. One with solid and cystic separation was rapidly hyperenhanced and cleared, and the filling subsided faster than the uterus. The postoperative pathological diagnosis was benign Brenner tumor with mucinous cystadenoma. The other three cases were solid adnexal lesions, which showed isoenhancement on CEUS and disappeared slowly, synchronizing with the uterus. The CEUS results were considered as benign tumors and confirmed by pathology.Conclusions: BBT can show ovarian cystic, mixed cystic and solid type, and solid echo in 2D ultrasound. Unilateral ovarian fibrosis with punctate calcification is an important feature of BBT in 2D ultrasound. However, for solid adnexal masses and mixed cystic and solid masses with unclear diagnosis, if CEUS shows isoenhancement or hyperenhancement, the possibility of BBT cannot be excluded.