This review examines studies of intra-operative contrast-enhanced ultrasound (CEUS) and its emerging role and advantages in robotic-assisted nephron-sparing surgery. Contrast-enhanced ultrasound is a technology that combines the use of second-generation contrast agents consisting of microbubbles with existent ultrasound techniques. Until now, this novel technology has aided surgeons with procedures involving the liver. However, with recent advances in the CEUS technique and the introduction of robotics in nephron-sparing surgery, CEUS has proven to be efficacious in answering several clinical questions with respect to the kidneys. In addition, the introduction of the microbubble-based contrast agents has increased the image quality and signal uptake by the ultrasound probe. This has led to better, enhanced scanning of the macro and microvasculature of the kidneys, making CEUS a powerful diagnostic modality. This imaging method is capable of further lowering the learning curve and warm ischemia time (WIT) during robotic-assisted nephron-sparing surgery, with its increased level of capillary perfusion and imaging. CEUS has the potential to increase the sensitivity and specificity of intra-operative images, and can significantly improve the outcome of robotic-assisted nephron-sparing surgery by increasing the precision and diagnostic insight of the surgeon. The purpose of this article is to review the practical and potential uses of CEUS as an intra-operative imaging technique during robotic-assisted nephron-sparing surgery.
1 January 2011 in Journal of Surgical Technique and Case Report
Penile prosthesis surgery plays a vital role in the treatment of erectile dysfunction (ED). As far as outcome is concerned, it is one of the most rewarding procedures for both patients and surgeons. We describe our surgical technique for implantation of the three-piece inflatable penile prosthesis and point out the major surgical pitfalls accompanying this procedure and their specific management. The psychological outcome of penile prosthesis surgery is also discussed. Different surgical approaches are available when performing the procedure. A number of procedure-related problems can be encountered and a thorough knowledge of these is of paramount importance. Penile prosthesis surgery has a favorable psychological outcome. Surgery for implantation of an inflatable penile prosthesis is a rewarding procedure, with a high yield of patient satisfaction. Urologists should have thorough understanding of the surgical pitfalls peculiar to this procedure and their management.
7 March 2016 in The International Journal of Medical Robotics and Computer Assisted Surgery
Objective: The open Anderson–Hynes procedure has an overall success rate of 90% for ureteropelvic junction obstruction. Laparoscopic pyeloplasty (LP) was developed to reduce morbidity and hospital stay while preserving the excellent results. We report on the results of our experience with laparoscopic pyeloplasty.Methods: Between January 2001 and May 2006, 77 consecutive patients underwent LP performed by one of 4 surgeons at our institution. Patients were reassessed with ultrasound (U/S) or intravenous pyelogram (IVP) at 6 weeks. Diuretic renal scan and U/S or IVP were performed at 6 months, and subsequent follow-up included a U/S or IVP as well as clinical assessment. Patients were assessed for pain and hydronephrosis on radiologic imaging, clearance on diuretic renal scan (T1/2) and differential renal function.Results: We evaluated 73 patients. The mean patient age was 38 years (range 16–71 yr), the mean operating time was 218 minutes (range 110–409 min), and the mean blood loss was 57 mL (range 25–250 mL). Mean hospital stay was 3.0 days (range 2–7 d). The success rate was 90.4%, and failures were mainly due to poor function after surgery (3 patients). Pyelolithotomy was performed concomitantly on 6 patients, which on average extended operative time by 36 minutes.Conclusion: Our success rates are consistent with the LP experience of other centres and are comparable with rates for the open technique. Patients had short hospital stays, and complications were negligible. With experienced surgeons, LP should be the first-line treatment for ureteropelvic junction obstruction.
Background: Incidence of biochemical recurrence (BCR) after radical prostatectomy is relatively high and overall survival can be poor. Debate exists whether tumour volume predicts BCR and when treatments should be administered. In this study, we aimed to i) assess the impact of tumour volume percentage (TVP) as a predictor for BCR, ii) determine TVP cut-off point for BCR and iii) evaluate single and composite predictors of BCR. Methods: From March 2000 to December 2013, 1777 patients underwent laparoscopic radical prostatectomy for localized prostate cancer. None received neoadjuvant or adjuvant therapy. One hundred and forty-six patients experienced BCR (range 3 months-10 years). Using D’Amico classification, 146 matched controls without BCR were compared. Liu cut-point analysis was used to identify TVP with optimal sensitivity and specificity. Single and composite BCR risk predictors were analyzed using Cox hazards regression in cases and controls. Results: Median TVP was 10% (range 1– 90%). Most of BCR peaked after 3 years of follow-up. TVP ≥ 8% was an independent predictor of BCR with HR 1.6 (p= 0.001, 95% CI= 1.11– 2.48). TVP of 8% was associated with the highest accuracy: sensitivity 74% and specificity 53% (ROC curve= 0.7). At TVP ≥ 8%, pathological stage pT3 was associated with 1.7-fold higher risk of BCR compared to T2. Lymph node invasion was associated with 1.4-fold higher risk of BCR compared to no invasion. Combining TVP ≥ 8%, pT3 and lymph node invasion, HR jumped to 3.73 (pConclusion: TVP can be used as an independent predictor of BCR after radical prostatectomy for prostate cancer. TVP cut-point of ≥ 8% allows the best discrimination. TVP should be considered in combination with other clinico-pathological factors to improve prediction of long-term oncological outcomes and to stratify BCR risk.