Cliburn Chan

Dr. Cliburn Chan

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Journal of Computational and Graphical Statistics
Verified
Journal Article
Closed access
MSMarc A. Suchard
Marc A. Suchard
QWQuanli Wang
Quanli Wang
CCCliburn Chan
Cliburn Chan
JFJacob Frelinger
Jacob Frelinger
ACAndrew Cron
Andrew Cron
MWMike West
Mike West
This article describes advances in statistical computation for large-scale data analysis in structured Bayesian mixture models via graphics processing unit (GPU) programming. The developments are p...

21 May 2008 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
CCCliburn Chan
Cliburn Chan
FFFeng Feng
Feng Feng
JOJanet Ottinger
Janet Ottinger
DFDavid Foster
David Foster
MWMike West
Mike West
TKThomas B. Kepler
Thomas B. Kepler
Statistical mixture modeling provides an opportunity for automated identification and resolution of cell subtypes in flow cytometric data. The configuration of cells as represented by multiple markers simultaneously can be modeled arbitrarily well as a mixture of Gaussian distributions in the dimension of the number of markers. Cellular subtypes may be related to one or multiple components of such mixtures, and fitted mixture models can be evaluated in the full set of markers as an alternative, or adjunct, to traditional subjective gating methods that rely on choosing one or two dimensions. Four color flow data from human blood cells labeled with FITC‐conjugated anti‐CD3, PE‐conjugated anti‐CD8, PE‐Cy5‐conjugated anti‐CD4, and APC‐conjugated anti‐CD19 Abs was acquired on a FACSCalibur. Cells from four murine cell lines, JAWS II, RAW 264.7, CTLL‐2, and A20, were also stained with FITC‐conjugated anti‐CD11c, PE‐conjugated anti‐CD11b, PE‐Cy5‐conjugated anti‐CD8a, and PE‐Cy7‐conjugated‐CD45R/B220 Abs, respectively, and single color flow data were collected on an LSRII. The data were fitted with a mixture of multivariate Gaussians using standard Bayesian statistical approaches and Markov chain Monte Carlo computations. Statistical mixture models were able to identify and purify major cell subsets in human peripheral blood, using an automated process that can be generalized to an arbitrary number of markers. Validation against both traditional expert gating and synthetic mixtures of murine cell lines with known mixing proportions was also performed. This article describes the studies of statistical mixture modeling of flow cytometric data, and demonstrates their utility in examples with four‐color flow data from human peripheral blood samples and synthetic mixtures of murine cell lines. © 2008 International Society for Advancement of Cytometry

11 July 2013 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
ACAndrew Cron
Andrew Cron
CGCécile Gouttefangeas
Cécile Gouttefangeas
JFJacob Frelinger
Jacob Frelinger
LLLin Lin
Lin Lin
SSSatwinder K. Singh
Satwinder K. Singh
CCCliburn Chan
Cliburn Chan
Flow cytometry is the prototypical assay for multi-parameter single cell analysis, and is essential in vaccine and biomarker research for the enumeration of antigen-specific lymphocytes that are often found in extremely low frequencies (0.1% or less). Standard analysis of flow cytometry data relies on visual identification of cell subsets by experts, a process that is subjective and often difficult to reproduce. An alternative and more objective approach is the use of statistical models to identify cell subsets of interest in an automated fashion. Two specific challenges for automated analysis are to detect extremely low frequency event subsets without biasing the estimate by pre-processing enrichment, and the ability to align cell subsets across multiple data samples for comparative analysis. In this manuscript, we develop hierarchical modeling extensions to the Dirichlet Process Gaussian Mixture Model (DPGMM) approach we have previously described for cell subset identification, and show that the hierarchical DPGMM (HDPGMM) naturally generates an aligned data model that captures both commonalities and variations across multiple samples. HDPGMM also increases the sensitivity to extremely low frequency events by sharing information across multiple samples analyzed simultaneously. We validate the accuracy and reproducibility of HDPGMM estimates of antigen-specific T cells on clinically relevant reference peripheral blood mononuclear cell (PBMC) samples with known frequencies of antigen-specific T cells. These cell samples take advantage of retrovirally TCR-transduced T cells spiked into autologous PBMC samples to give a defined number of antigen-specific T cells detectable by HLA-peptide multimer binding. We provide open source software that can take advantage of both multiple processors and GPU-acceleration to perform the numerically-demanding computations. We show that hierarchical modeling is a useful probabilistic approach that can provide a consistent labeling of cell subsets and increase the sensitivity of rare event detection in the context of quantifying antigen-specific immune responses. The use of flow cytometry to count antigen-specific T cells is essential for vaccine development, monitoring of immune-based therapies and immune biomarker discovery. Analysis of such data is challenging because antigen-specific cells are often present in frequencies of less than 1 in 1,000 peripheral blood mononuclear cells (PBMC). Standard analysis of flow cytometry data relies on visual identification of cell subsets by experts, a process that is subjective and often difficult to reproduce. Consequently, there is intense interest in automated approaches for cell subset identification. One popular class of such automated approaches is the use of statistical mixture models. We propose a hierarchical extension of statistical mixture models that has two advantages over standard mixture models. First, it increases the ability to detect extremely rare event clusters that are present in multiple samples. Second, it enables direct comparison of cell subsets by aligning clusters across multiple samples in a natural way arising from the hierarchical formulation. We demonstrate the algorithm on clinically relevant reference PBMC samples with known frequencies of CD8 T cells engineered to express T cell receptors specific for the cancer-testis antigen (NY-ESO-1) and compare its performance with other popular automated analysis approaches.

4 November 2020 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
JJJennifer A. Jenks
Jennifer A. Jenks
CNCody S. Nelson
Cody S. Nelson
HRHunter K. Roark
Hunter K. Roark
MGMatthew L. Goodwin
Matthew L. Goodwin
RPRobert F. Pass
Robert F. Pass
SPSallie Permar
Sallie Permar
Protection against CMV correlates with gB/MF59 vaccine-elicited IgG that binds cell-associated gB.

12 June 2007 in BMC Bioinformatics
Verified
Journal Article
Open access
PDF file
AYAndrew Yates
Andrew Yates
CCCliburn Chan
Cliburn Chan
JSJessica Strid
Jessica Strid
SMSimon Moon
Simon Moon
RCRobin Callard
Robin Callard
JSJaroslav Stark
Jaroslav Stark
Quantifying cell division and death is central to many studies in the biological sciences. The fluorescent dye CFSE allows the tracking of cell division in vitro and in vivo and provides a rich source of information with which to test models of cell kinetics. Cell division and death have a stochastic component at the single-cell level, and the probabilities of these occurring in any given time interval may also undergo systematic variation at a population level. This gives rise to heterogeneity in proliferating cell populations. Branching processes provide a natural means of describing this behaviour.

19 June 2010 in Cancer Immunology, Immunotherapy
Verified
Journal Article
Open access
PDF file
JFJacob Frelinger
Jacob Frelinger
JOJanet Ottinger
Janet Ottinger
CGCécile Gouttefangeas
Cécile Gouttefangeas
CCCliburn Chan
Cliburn Chan
Flow cytometry (FCM) is widely used in cancer research for diagnosis, detection of minimal residual disease, as well as immune monitoring and profiling following immunotherapy. In all these applications, the challenge is to detect extremely rare cell subsets while avoiding spurious positive events. To achieve this objective, it helps to be able to analyze FCM data using multiple markers simultaneously, since the additional information provided often helps to minimize the number of false positive and false negative events, hence increasing both sensitivity and specificity. However, with manual gating, at most two markers can be examined in a single dot plot, and a sequential strategy is often used. As the sequential strategy discards events that fall outside preceding gates at each stage, the effectiveness of the strategy is difficult to evaluate without laborious and painstaking back-gating. Model-based analysis is a promising computational technique that works using information from all marker dimensions simultaneously, and offers an alternative approach to flow analysis that can usefully complement manual gating in the design of optimal gating strategies. Results from model-based analysis will be illustrated with examples from FCM assays commonly used in cancer immunotherapy laboratories.