Lakshman Subbaraman

Dr. Lakshman Subbaraman


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2006 in Current Eye Research
Verified
Journal Article
Closed access
LSLakshman Subbaraman
Lakshman Subbaraman
MGMary-Ann Glasier
Mary-Ann Glasier
MSMichelle Senchyna
Michelle Senchyna
HSHeather Sheardown
Heather Sheardown
Lyndon JonesLyndon Jones
Lyndon Jones
We sought to compare the kinetics of in vitro lysozyme deposition on silicone hydrogel (SH), polymethyl methacrylate (PMMA), and FDA groups I, II, and IV contact lenses. Lenses were incubated in 125I-labeled lysozyme for time periods ranging from 1 hr to 28 days, and radioactive counts were determined. SH lenses and PMMA deposited less lysozyme than conventional hydrogel lenses (p < 0.05). Lysozyme accumulation on group IV lenses reached a maximum on the seventh day and then plateaued, whereas on groups I, II, and SH lenses, deposition continued to increase across all time periods, reiterating that kinetics of lysozyme deposition is highly material dependent.

1 October 2012 in Optometry and Vision Science
Verified
Journal Article
Closed access
LSLakshman Subbaraman
Lakshman Subbaraman
MGMary‐Ann Glasier
Mary‐Ann Glasier
JVJalaiah Varikooty
Jalaiah Varikooty
SSSruthi Srinivasan
Sruthi Srinivasan
Lyndon JonesLyndon Jones
Lyndon Jones

1 March 2013 in Eye & Contact Lens: Science & Clinical Practice
Verified
Journal Article
Closed access
Chau-Minh PhanChau-Minh Phan
Chau-Minh Phan
LSLakshman Subbaraman
Lakshman Subbaraman
Lyndon JonesLyndon Jones
Lyndon Jones
Objectives: To investigate the uptake and release of the antifungal ocular drug, natamycin from commercially available conventional hydrogel (CH) and silicone hydrogel (SH) contact lens (CL) materials and to evaluate the effectiveness of this delivery method. Methods: Five commercial SH CLs (balafilcon A, comfilcon A, galyfilcon A, senofilcon A, and lotrafilcon B) and four CH CLs (etafilcon A, omafilcon A, polymacon, vifilcon A) were examined in this study. These lenses were incubated with natamycin solubilized in dimethyl sulfoxide, and the release of the drug from these lenses, in Unisol 4 pH 7.4 at 32±1°C, was determined using UV-visible spectrophotometry at 305 nm over 24 hours. Results: There was a significant uptake of natamycin between 0 hour and 24 hours (P0.05). There was a significant difference in release between all the SH materials (P<0.05) and CH materials (P<0.05). All CL materials showed a significant increase in the release of natamycin until 1 hour (P0.05). Overall, the release of natamycin was higher in CH than SH lenses (P<0.001). Conclusions: All CLs released clinically relevant concentrations of natamycin within 30 minutes, but this release reached a plateau after approximately 1 hour. Further CL material development will be necessary to produce a slow and sustained drug releasing device for the delivery of natamycin.

1 January 2010 in Journal of Biomaterials Science, Polymer Edition
Verified
Journal Article
Closed access
LSLakshman Subbaraman
Lakshman Subbaraman
Lyndon JonesLyndon Jones
Lyndon Jones
We determined the activity of lysozyme recovered from various conventional and silicone hydrogel (SH) contact lens materials as a function of time, using an in vitro model. Polymacon, omafilcon, etafilcon, vifilcon, lotrafilcon A, lotrafilcon B, balafilcon A, galyfilcon A and senofilcon A contact lenses (n = 5) were incubated in lysozyme solution for time periods ranging from 1 h to 28 days. Following the specified incubation period, the lysozyme deposited on the lenses was extracted and the sample extracts were assessed for lysozyme activity and total lysozyme. We found no significant difference (NSD) between omafilcon and polymacon lens materials for the initial 3 days (P > 0.05); however, there was a significant difference between the two lenses from 5 to 28 days (P < 0.05). There was NSD (P > 0.05) between etafilcon and vifilcon lens materials at all time-points and significant differences were seen between various SH lens materials at different time points. After 28 days, lysozyme deposited on etafil...

1 July 2007 in Eye & Contact Lens: Science & Clinical Practice
Verified
Journal Article
Closed access
LSLakshman Subbaraman
Lakshman Subbaraman
MGMary Ann M.Sc Glasier
Mary Ann M.Sc Glasier
MSMichelle Senchyna
Michelle Senchyna
HSHeather Sheardown
Heather Sheardown
Lyndon JonesLyndon Jones
Lyndon Jones
Purpose. Extracting lysozyme from Food and Drug Administration group IV etafilcon lenses by using 0.2% trifluoroacetic acid and acetonitrile (TFA/ACN) is a well-established procedure. TFA/ACN has been the extraction buffer of choice for extracting proteins from silicone hydrogel contact lenses. The purpose of this study was to determine the efficiency of TFA/ACN in extracting lysozyme from silicone hydrogel and etafilcon lenses by using an in vitro model. Methods. ACUVUE 2, Focus NIGHT & DAY, O2 Optix, PureVision, and ACUVUE Advance lenses were incubated in simple lysozyme solution and a complex artificial tear solution consisting of multiple tear components containing lysozyme labeled with iodine 125. All the silicone hydrogel lenses were incubated for 28 days, whereas the ACUVUE 2 lenses were incubated for 7 days at 37°C with constant rotation. After the incubation period, radioactive counts were determined, and the lenses were placed in an appropriate volume of the buffer for 24 hours in darkness. The lenses were removed from the buffer, and radioactive counts were determined again. Results. Extraction efficiencies for lysozyme from the artificial tear solution were 97.2% ± 1.2% for ACUVUE 2, 64.3% ± 6.2% for Focus NIGHT & DAY, 62.5% ± 5.6% for O2 Optix, 53.5% ± 5.8% for PureVision, and 89.2% ± 3.4% for ACUVUE Advance. Results were similar for the lysozyme extracted after incubating in the simple lysozyme solution. Conclusions. TFA/ACN is extremely efficient at extracting lysozyme deposited on etafilcon lenses. However, it does not extract all the lysozyme deposited on silicone hydrogel lenses, and alternative extraction procedures should be sought.

1 March 2009 in Eye & Contact Lens: Science & Clinical Practice
Verified
Journal Article
Closed access
LSLakshman Subbaraman
Lakshman Subbaraman
MGMary Ann Glasier
Mary Ann Glasier
HSHeather Sheardown
Heather Sheardown
Lyndon JonesLyndon Jones
Lyndon Jones
Extracting proteins from conventional hydrogel (CH) and silicone hydrogel (SH) contact lens materials using a mixture of trifluoroacetic acid/acetonitrile (TFA/ACN) is a well-established procedure for quantifying individual and total protein deposited on contact lenses. The purpose of this study was to determine the efficacy of TFA/ACN in extracting albumin from SH and a CH group IV lens material using an in vitro model. One CH group IV lens material (etafilcon A) and five different SH lens materials (lotrafilcon A, lotrafilcon B, balafilcon A, galyfilcon A, and senofilcon A) were incubated in both simple albumin solution and a complex artificial tear protein solution containing 125I-labeled albumin. All the lens materials were incubated for 14 days at 37 degrees C with constant rotations. Following the incubation period, radioactive counts were determined and the lenses were placed in an appropriate volume of the extraction solvent. After the specified time, the lenses were removed and radioactive counts were determined again to calculate the amount of albumin remaining on the lenses post-extraction. Extraction efficiencies for albumin from the artificial tear protein solution were 97.2% +/- 2 for etafilcon A, 77.3% +/- 6.2 for lotrafilcon A, 73.5% +/- 5.6 for lotrafilcon B, 81.5% +/- 5.8 for balafilcon, 91.2% +/- 3.4 for galyfilcon A, and 89.2% +/- 3.4 for senofilcon A. Results were similar for the albumin extracted after incubating in the simple albumin solution. Although TFA/ACN is efficient at extracting albumin deposited on etafilcon lenses, it does not extract all the albumin that is deposited on SH lenses and alternative extraction procedures should be sought.