Background: Medial meniscus posterior root (MMPR) tears are recognized as a substantial cause of disability and morbidity. However, meniscus root repair, regardless of technique, is not without potential complications. Purpose: To evaluate the reported incidence of complications and adverse events after isolated MMPR repair. Study Design: Systematic review; Level of evidence, 4. Methods: A systematic review was conducted according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using Embase, PubMed, and Scopus databases with the following search terms combined with Boolean operators: “meniscus,”“root,” and “repair.” Inclusion criteria consisted of level 1 to 4 human clinical studies in English or English-language translation reporting complications and adverse events after isolated posterior medial meniscus root repairs. The overall incidence of specific complications was estimated from the pooled sample of the included studies. Results: Eleven studies with a total pooled sample of 442 patients were identified. The mean patient age was 58.1 years, while the mean final follow-up time was 37.2 months (range, 12-84.8 months). The overall incidence of complications was 9.7% (n = 43/442), with the most commonly reported complication being progressive degenerative changes within the knee (10.4%; n = 25/240; n = 5 studies). A total of 1.25% (n = 3/240) of patients who experienced degenerative changes required conversion to total knee arthroplasty. Repair failures were reported in 3.1% (n = 10/327; n = 8 studies) of patients. Conclusion: Repairing MMPR tears is critical in preventing accelerated progression of knee osteoarthritis in patients without significant knee osteoarthritis preoperatively. While this repair is still recommended and necessary in appropriate patients, this review found that the incidence of complications after isolated posterior medial meniscus root repair was 9.7%, primarily involving the presence of progressive degeneration, while repair failure was reported in 3% of patients.
» Asymptomatic snapping hip affects 5% to 10% of the population; when pain becomes the primary symptom, it is classified as snapping hip syndrome (SHS). » The snap can be felt on the lateral side of the hip (external snapping hip), often attributed to an iliotibial band interaction with the greater trochanter, or on the medial side (internal snapping hip), often attributed to the iliopsoas tendon snapping on the lesser trochanter. » History and physical examination maneuvers can help distinguish the etiology, and imaging may help confirm diagnosis and rule out other pathologies. » A nonoperative strategy is used initially; in the event of failure, several surgical procedures are discussed in this review along with their pertinent analyses and key points. » Both open and arthroscopic procedures are based on the lengthening of the snapping structures. While open and endoscopic procedures both treat external SHS, endoscopic procedures typically have lower complication rates and better outcomes when treating internal SHS. This distinction does not appear to be as noticeable in the external SHS.
There has been growing interest in the use of patient-specific instrumentation (PSI) to maximise accuracy and minimise the risk of major complications for medial opening-wedge high tibial osteotomies (MOW-HTOs). Numerous studies have reported the efficacy and safety of implementing this technology into clinical practice, yet no systematic review summarising the clinical literature on PSI for MOW-HTOs has been performed to date. The aim of this investigation was to perform a systematic review summarising the evidence surrounding the use of PSI for MOW-HTOs in the management of medial compartment osteoarthritis. PubMed, Scopus, and the Cochrane Library were queried in October 2021 for studies that used PSI for MOW-HTOs when managing medial compartment knee osteoarthritis. Primary outcomes included accuracy in coronal plane correction (mechanical medial proximal tibial angle), sagittal plane correction (posterior tibial slope), and mechanical axis correction (hip-knee-ankle angle [HKA], mechanical femorotibial angle, and weight-bearing line). Accuracy was defined as error between post-operative measurements relative to the planned pre-operative correction. A secondary outcome was the incidence of major complications. This review included eight different techniques among the 14 included studies. There was a weighted mean error of 0.5° (range: 0.1°-1.3°) for the mechanical medial proximal tibial angle, 0.6° (range: 0.3°-2.7°) for the posterior tibial slope, and 0.8° (range: 0.1°-1.0°) for the hip-knee-ankle angle. Four studies compared the correctional error of the mechanical axis between conventional techniques and PSI techniques. The comparative difference between the two techniques favoured the use of PSI for MOW-HTOs (standardised mean difference = 0.52; 95% confidence interval, 0.16 to 0.87; p = 0.004). Among the 14 studies evaluated, four studies explicitly reported no major complications, while five studies reported a non-zero incidence of major complications. Among these nine studies, the weighted mean major complication rate was 7.1% (range: 0.0-13.0%). The findings of this present systematic review suggest that the use of PSI for MOW-HTOs leads to high accuracy relative to the planned corrections in the coronal plane, sagittal plane, and mechanical axis. Furthermore, these findings would suggest there is a low risk of major complications when implementing PSI for MOW-HTOs. Systematic review; IV.