Annual mean wind speed distribution models for power generation based on regional wind resource maps are limited by spatial and temporal resolutions. These models, in general, do not consider the impact of local terrain and atmospheric circulations. In this study, long-term five-year wind data at three sites on the North, East, and West of the Baltimore metropolitan area, Maryland, USA are statistically analyzed. The Weibull probability density function was defined based on the observatory data. Despite seasonal and spatial variability in the wind resource, the annual mean wind speed for all sites is around 3 m/s, suggesting the region is not suitable for large-scale power generation. However, it does display a wind power capacity that might allow for non-grid connected small-scale wind turbine applications. Technical and economic performance evaluations of more than 150 conventional small-scale wind turbines showed that an annual capacity factor and electricity production of 11% and 1990 kWh, respectively, are achievable. It results in a payback period of 13 years. Government incentives can improve the economic feasibility and attractiveness of investments in small wind turbines. To reduce the payback period lower than 10 years, modern/unconventional wind harvesting technologies are found to be an appealing option in this region. Key contributions of this work are (1) highlighting the need for studying the urban physics rather than just the regional wind resource maps for wind development projects in the build-environment, (2) illustrating the implementation of this approach in a real case study of Maryland, and (3) utilizing techno-economic data to determine suitable wind harnessing solutions for the studied sites.
Pumping fluid is essential to numerous applications across a wide range of scales from viscous dominated to inertia driven flows. Most traditional applications occur within a range where inertia is the dominating factor influencing the pump performance, and hence many practical designs are based on mechanisms that rely on this assumption. As one explores smaller devices, however, the increasing effect of viscosity renders these traditional mechanisms ineffective. In the current work, a bio-inspired pump is constructed from a two-dimensional oscillating solid and flexible plate to study the effect of diminishing inertia within a narrow channel. The goal is to quantify and better understand the role played by a shift from symmetric to asymmetric kinematics of an oscillating rigid or flexible plate in the transition regime between viscous and inertia dominated flows. This is done through both a temporal asymmetry using a rigid plate (e.g. scallop) and a geometric asymmetry using a passive one-way hinged articulation (e.g. jellyfish). One-way flexibility results in a rigid plate during the effective stroke while permitting a simple hinged articulation during the recovery stroke. The waveform used for the temporally asymmetric case consists of a basic triangle waveform which could generate faster effective strokes than recovery strokes. The results of the single-plate tests indicate that increased asymmetry introduced in the triangular wave actuation leads to increased pumping performance and energy consumption. In the case of flexible plates, the results show that a mass-specific pumping efficiency was higher for a higher actuation frequency at the same Reynolds numbers.
Urban morphology significantly influences wind flow patterns within dense cityscapes, affecting ventilation, structural loads, and climate-responsive design. This study develops a systematic framework to quantify the effects of morphological parameters (MPs) such as plan area density, height ratio, façade area density, aspect ratio, and building cross-sectional shapes on local mean wind velocity around and above a high-rise building embedded within parametrically controlled urban morphologies. A total of 75 selected urban configurations were evaluated using 275 validated CFD simulations across the full wind rose with 22.5° directional increments. Four non-dimensional wind velocity metrics were evaluated at key vertical levels, including pedestrian height, canopy level, and two rooftop levels capturing near- and far-wake effects, to characterize spatial variation in local mean wind velocity relevant to pedestrian comfort, outdoor ventilation, and urban renewable energy applications. The objective is to characterize, parameterize, and quantify these effects on local mean wind behavior to provide interpretable insights for wind-aware urban design and planning. Results show strong linear decay in wind speed at pedestrian level and rooftop levels with increasing plan area density, and non-monotonic responses to height ratio, with velocity minima consistently occurring near a height ratio of 0.6 across all evaluated levels. The influence of façade density on wind behavior also varies depending on whether it is driven by plan-area density or height ratio, revealing coupled aerodynamic effects. These findings establish a foundational reference for local-level urban wind simulation. Unlike prior case-specific or isolated-building studies, this work delivers generalized insights into morphology–flow coupling through a structured parametric framework, supporting predictive modeling and resilient urban design.