Claudio Macculi

Dr. Claudio Macculi

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2018
Verified
Conference Paper
Closed access
PDF file
DBDidier Barret
Didier Barret
JHJan-Willem Den Herder
Jan-Willem Den Herder
TTThien Lam Trong
Thien Lam Trong
LPLuigi Piro
Luigi Piro
MCMassimo Cappi
Massimo Cappi
LNLorenzo Natalucci
Lorenzo Natalucci
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5’ equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ∼ 5” pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at ∼ 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 μm. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of ∼ 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (< 50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018.

17 August 2016
Verified
Conference Paper
Closed access
PDF file
DBDidier Barret
Didier Barret
TTThien Lam Trong
Thien Lam Trong
JHJan-Willem Den Herder
Jan-Willem Den Herder
LPLuigi Piro
Luigi Piro
XBXavier Barcons
Xavier Barcons
ECEdoardo Cucchetti
Edoardo Cucchetti
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with ~ 5" pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we brie y describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution).

9 April 2018 in Journal of Low Temperature Physics
Verified
Journal Article
Closed access
PDF file
FPF. Pajot
F. Pajot
DBD. Barret
D. Barret
TLT. Lam-Trong
T. Lam-Trong
JHJ.-W. Den Herder
J.-W. Den Herder
LPL. Piro
L. Piro
PPP. Peille
P. Peille

20 December 2011 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Open access
BJB. D. Jackson
B. D. Jackson
PKP. A. J. de Korte
P. A. J. de Korte
JKJ. van der Kuur
J. van der Kuur
PMP. D. Mauskopf
P. D. Mauskopf
JBJ. Beyer
J. Beyer
SWS. Withington
S. Withington
The SAFARI instrument is a far-infrared imaging Fourier transform spectrometer for JAXA's SPICA mission. Taking advantage of the low emission of SPICA's 5 K telescope, SAFARI will provide sky background-limited, Nyquist-sampled spectroscopic imaging of a 2 ' × 2 ' field-of-view over 34-210 μm, creating significant new possibilities for far-infrared astronomy. SAFARI's aggressive science goals drive the development of a unique detector system combining large-format Transition Edge Sensor arrays and frequency division multiplexed SQUID readout with a high 160x multiplexing factor. The detectors and their cold readout electronics are packaged into 3 focal plane arrays that will be integrated into SAFARI's focal plane unit. Here we present the preliminary system design and current development status of the SAFARI detector system.

24 July 2014
Verified
Conference Paper
Closed access
PDF file
LRL. Ravera
L. Ravera
DBD. Barret
D. Barret
JHJ. Den Herder
J. Den Herder
LPL. Piro
L. Piro
RCR. Clédassou
R. Clédassou
CSC. Schmid
C. Schmid
Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), offering 2:5 eV spectral resolution, with ~5" pixels, over a field of view of 50 in diameter. In this paper, we present the X-IFU detector and readout electronics principles, some elements of the current design for the focal plane assembly and the cooling chain. We describe the current performance estimates, in terms of spectral resolution, effective area, particle background rejection and count rate capability. Finally, we emphasize on the technology developments necessary to meet the demanding requirements of the X-IFU, both for the sensor, readout electronics and cooling chain

23 September 2014 in Astronomy & Astrophysics
Verified
Journal Article
Open access
PDF file
SLSimone Lotti
Simone Lotti
DCD. Cea
D. Cea
CMClaudio Macculi
Claudio Macculi
TMT. Mineo
T. Mineo
LNL. Natalucci
L. Natalucci
BMB. Martino
B. Martino
Context. Observations in the X-ray energy band are often limited by the background because of the low fluxes of typical sources. The background can easily be higher than the signal itself, and thus any mission with the scientific goal of observing faint and/or extended sources in the X-ray band must deal with the background problem. ESA has recently selected “the hot and energetic universe” as science theme for the second large-class mission in the Cosmic Vision science program, to be pursued with an advanced X-ray observatory to be launched in 2028, and at present ATHENA is the proposal that is most likely to be selected for this slot. The mission is aimed to place an X-ray telescope in the L2 orbit equipped with an X-ray Integral Field Unit (X-IFU) based on high spectral resolution transition-edge microcalorimeters, and has among its goals the detection and characterization of high-redshift active galactic nuclei (AGNs), cluster of galaxies and their outskirts, which is why great care must be taken to reduce the background impact on the detection/characterization of these sources. Aims. The background is composed of a diffuse component and an internal particle component for any satellite operating in the X-ray band. We take as reference the X-ray IFU instrument that will be placed onboard the ATHENA mission to analyze both these components and their variability for different orbits, observational conditions and/or design choices. We also show how different background levels affect the instrumental performance, and the scientific results obtainable with the instrument in the best configuration. The X-IFUis a cryogenic X-ray spectrometer, based on a large array of 3840 transition-edge sensors (TES) of 250 μm side, with a spectral energy resolution of 2.5 eVin the 0.2−10 keVenergy band, over a field of view of 5 × 5 arcmin2, high count rate capability and a 5 arcsec angular resolution.Methods. There are no experimental data about the background experienced by microcalorimeters in the L2 orbit, and thus the particle background levels were calculated by means of Monte Carlo simulations: we considered the original design configuration and an improved configuration aimed to reduce the unrejected background, and tested them in the L2 orbit and in the low Earth orbit, comparing the results with experimental data reported by other X-ray instruments. For the diffuse component, we used the background levels measured from a 1 sr region representative of typical high galactic latitude pointings and analyzed the variations expected with the different orbital conditions. To show the results obtainable with the improved configuration we simulated the observation of a faint, high-redshift, point source (F [ 0.5 − 10 keV ] ~ 6.4 × 10-16 erg cm-2 s-1, z = 3.7), and of a hot galaxy cluster at R 200 (S b [ 0.5−2 keV ] = 8.61 × 10-16 erg cm-2 s-1 arcmin-2, T = 6.6 keV).Results. First we confirm that implementing an active cryogenic anticoincidence reduces the particle background by an order of magnitude and brings it close to the required level. The implementation and test of several design solutions can reduce the particle background level by a further factor of 6 with respect to the original configuration. The residual background is dominated by secondary particles, and this component can be decreased by design solutions such as passive shielding with appropriate materials. The best background level achievable in the L2 orbit with the implementation of ad-hoc passive shielding for secondary particles is similar to that measured in the more favorable LEO environment without the passive shielding, allowing us to exploit the advantages of the L2 orbit. We define a reference model for the diffuse background and collect all the available information on its variation with epoch and pointing direction. With this background level the ATHENA mission with the X-IFU instrument is able to detect ~4100 new obscured AGNs with F> 6.4 × 10-16 erg cm-2 s-1 during three years, to characterize cluster of galaxies with S b (0.5 − 2 keV) > 9.4 × 10-16 erg cm-2 s-1 sr-1 on timescales of 50 ks (500 ks) with errors <~40% (<~12%) on metallicity, <~16% (~4.8%) on temperature, ~2.6% (~0.72%) on the gas density, and several single-element abundances.Conclusions. With respect to the original design the background level obtained significantly enhances the performance of the X-IFU. It allows us to improve the times needed for the detection and the characterization of high-redshift and/or faint Compton-thick AGNs and to reduce the limit flux of X-IFU, and thus to have a significant measurement of the fraction of these objects where current surveys are missing data. Moreover, the reduced background allows an improved characterization of diffuse and/or faint sources in terms of relative errors on the physical properties of the sources and observational times needed to obtain them.