Rachel W. Walmer

Dr. Rachel W. Walmer

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2022 in Kidney360
Verified
Journal Article
Closed access
PDF file
ASAnand Srivastava
Anand Srivastava
ASAnush Sridharan
Anush Sridharan
RWRachel W. Walmer
Rachel W. Walmer
SKSandeep K. Kasoji
Sandeep K. Kasoji
LBLauren M.B. Burke
Lauren M.B. Burke
ECEmily Hueywen Chang
Emily Hueywen Chang
Background: Individuals with chronic kidney disease (CKD) have decreased kidney cortical microvascular perfusion, which may lead to worsening kidney function over time, but methods to quantify kidney cortical microvascular perfusion are not feasible to incorporate into clinical practice. Contrast-enhanced ultrasound (CEUS) may quantify kidney cortical microvascular perfusion, which requires further investigation in individuals across the spectrum of kidney function. Methods: We performed CEUS on a native kidney of 83 individuals across the spectrum of kidney function and calculated quantitative CEUS-derived kidney cortical microvascular perfusion biomarkers. Participants had a continuous infusion of the microbubble contrast agent (Definity) with a flash-replenishment sequence during their CEUS scan. Lower values of the microbubble velocity (β) and perfusion index (β×A) may represent lower kidney cortical microvascular perfusion. Multivariable linear regression models tested the associations of the microbubble velocity (β) and perfusion index (β×A) with estimated glomerular filtration rate (eGFR). Results: Thirty-eight individuals with CKD (mean age±SD 65.2±12.6 years, median [IQR] eGFR 31.5 [18.9–41.5] ml/min per 1.73 m2), 37 individuals with end stage kidney disease (ESKD; age 54.8±12.3 years), and eight healthy volunteers (age 44.1±15.0 years, eGFR 117 [106–120] ml/min per 1.73 m2) underwent CEUS without side effects. Individuals with ESKD had the lowest microbubble velocity (β) and perfusion index (β×A) compared with individuals with CKD and healthy volunteers. The microbubble velocity (β) and perfusion index (β×A) had moderate positive correlations with eGFR (β: r s=0.44, P<0.001; β×A: r s=0.50, P<0.001). After multivariable adjustment, microbubble velocity (β) and perfusion index (β×A) remained significantly associated with eGFR (change in natural log transformed eGFR per 1 unit increase in natural log transformed biomarker: β, 0.38 [95%, CI 0.17 to 0.59]; β×A, 0.79 [95% CI, 0.45 to 1.13]). Conclusions: CEUS-derived kidney cortical microvascular perfusion biomarkers are associated with eGFR. Future studies are needed to determine if CEUS-derived kidney cortical microvascular perfusion biomarkers have prognostic value.

5 October 2022 in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
TKThomas M. Kierski
Thomas M. Kierski
RWRachel W. Walmer
Rachel W. Walmer
JTJames K. Tsuruta
James K. Tsuruta
JYJianhua Yin
Jianhua Yin
ECEmmanuel Cherin
Emmanuel Cherin
PDPaul Dayton
Paul Dayton
Ultrasound molecular imaging (USMI) is a technique used to noninvasively estimate the distribution of molecular markers in vivo by imaging microbubble contrast agents (MCAs) that have been modified to target receptors of interest on the vascular endothelium. USMI is especially relevant for preclinical and clinical cancer research and has been used to predict tumor malignancy and response to treatment. In the last decade, methods that improve the resolution of contrast-enhanced ultrasound by an order of magnitude and allow researchers to noninvasively image individual capillaries have emerged. However, these approaches do not translate directly to molecular imaging. In this work, we demonstrate super-resolution visualization of biomarker expression in vivo using superharmonic ultrasound imaging (SpHI) with dual-frequency transducers, targeted contrast agents, and localization microscopy processing. We validate and optimize the proposed method in vitro using concurrent optical and ultrasound microscopy and a microvessel phantom. With the same technique, we perform a proof-of-concept experiment in vivo in a rat fibrosarcoma model and create maps of biomarker expression co-registered with images of microvasculature. From these images, we measure a resolution of $23~\mathrm {\mu}{\text {m}}$ , a nearly fivefold improvement in resolution compared to previous diffraction-limited molecular imaging studies.

12 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RWRachel W. Walmer
Rachel W. Walmer
VRVictor S. Ritter
Victor S. Ritter
ASAnush Sridharan
Anush Sridharan
SKSandeep K. Kasoji
Sandeep K. Kasoji
EAErsan Altun
Ersan Altun
ECEmily Hueywen Chang
Emily Hueywen Chang
We investigated the accuracy of CEUS for characterizing cystic and solid kidney lesions in patients with chronic kidney disease (CKD). Cystic lesions are assessed using Bosniak criteria for computed tomography (CT) and magnetic resonance imaging (MRI); however, in patients with moderate to severe kidney disease, CT and MRI contrast agents may be contraindicated. Contrast-enhanced ultrasound (CEUS) is a safe alternative for characterizing these lesions, but data on its performance among CKD patients are limited. We performed flash replenishment CEUS in 60 CKD patients (73 lesions). Final analysis included 53 patients (63 lesions). Four readers, blinded to true diagnosis, interpreted each lesion. Reader evaluations were compared to true lesion classifications. Performance metrics were calculated to assess malignant and benign diagnoses. Reader agreement was evaluated using Bowker’s symmetry test. Combined reader sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for diagnosing malignant lesions were 71%, 75%, 45%, and 90%, respectively. Sensitivity (81%) and specificity (83%) were highest in CKD IV/V patients when grouped by CKD stage. Combined reader sensitivity, specificity, PPV, and NPV for diagnosing benign lesions were 70%, 86%, 91%, and 61%, respectively. Again, in CKD IV/V patients, sensitivity (81%), specificity (95%), and PPV (98%) were highest. Inter-reader diagnostic agreement varied from 72% to 90%. In CKD patients, CEUS is a potential low-risk option for screening kidney lesions. CEUS may be particularly beneficial for CKD IV/V patients, where kidney preservation techniques are highly relevant.