pandi mani

Dr. pandi mani


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2021 in Journal of Building Pathology and Rehabilitation
Verified
Journal Article
Closed access
PDF file
PMpandi mani
pandi mani
MPMarkandeya Raju Ponnada
Markandeya Raju Ponnada
YGYesuratnam Geddada
Yesuratnam Geddada

27 July 2023 in Asian Journal of Civil Engineering
Verified
Journal Article
Closed access
PDF file
PMpandi mani
pandi mani
TSTanikonda Siva Sankar
Tanikonda Siva Sankar
BPB. P. R. V. S. Priyatham
B. P. R. V. S. Priyatham
BRB. A. V. Ramkumar
B. A. V. Ramkumar

22 May 2023 in Multidiscipline Modeling in Materials and Structures
Verified
Journal Article
Closed access
PMpandi mani
pandi mani
Purpose: The ultimate capacity and ductility behavior of a reinforced concrete (RC) beam generally depends on its constituent material properties. This study aims to use ANSYS to accentuate the nonlinear parametric finite element (FE) simulations of RC sections under monotonic loading.Design/methodology/approach: The concrete matrix and steel reinforcement are the primary constituent materials of RC beams. The material properties such as tensile reinforcement area, tensile bars yield strength, concrete compressive strength and strain rate in tensile reinforcement at nominal strength have significantly influenced the ultimate response of RC beams. Therefore, these intensive parameters are considered in this study to ascertain their effect on the RC beam's ultimate behavior. The nonlinear response up to the ultimate load capacity and the crack evolutions of RC beams are predicted efficiently.Findings: The parametric study reveals that increasing the tensile steel reinforcements (from Ast = 213–857 mm2) significantly improves the ultimate load capacity by 229% and yield deflections by 20%. However, it declines the ultimate deflection by 47% and ductility by 56% substantially. Varying the strain limit (?tn = 0.010–0.0015) of tensile reinforcement has proficiently increased the ultimate load-resisting capacity by 20%, whereas the ductility declined by 62%. When the concrete strength increases (from fck = 25–65 MPa), the cracking load increases profoundly by 51%, whereas the ultimate capacity has found an insignificant effect.Originality/value: The load-deflection response plots extracted from the proposed numerical model exhibit satisfactory accuracy (less than 9% deviation) against the experimental curves available in the literature, which emphasizes the proficiency of the proposed FE model.

2 July 2023 in Asian Journal of Civil Engineering
Verified
Journal Article
Closed access
PDF file
PMpandi mani
pandi mani
YRYeduvaka Damodara Rao
Yeduvaka Damodara Rao
IKIjada Gopala Krishna
Ijada Gopala Krishna

5 March 2025 in Asian Journal of Civil Engineering
Verified
Journal Article
Closed access
PDF file
PMpandi mani
pandi mani
YRY. Raviteja
Y. Raviteja
PBP. Bilgates
P. Bilgates
SKS. H. Vamsi Krishna
S. H. Vamsi Krishna

19 February 2025 in Engineering Research Express
Verified
Journal Article
Closed access
PMpandi mani
pandi mani
BPBilgates P
Bilgates P
RYRaviteja Y
Raviteja Y
PAP D V S Akhil
P D V S Akhil
SYSowmya Y
Sowmya Y
Building information modeling (BIM) allows structures to be digitally designed and visualized before physical construction begins, effectively addressing and eliminating many inefficiencies and issues that typically arise during the construction process. This research evaluates the seismic design and energy consumption of Reinforced Concrete (RC) buildings using different BIM tools. The impact of different building configurations (including window-wall ratio, shading, and automation sensor effects) and orientation on the electrical energy consumption are evaluated. Integrating these factors into energy analysis can enhance conceptual design, leading to better environmental effectiveness and aiding in the achievement of environmental sustainability goals. The study determined that aligning the building at true north (zero degrees), using two-thirds window shade height, maintaining a 0% window-wall ratio, and integrating day-lighting and occupancy sensors resulted in the most effective energy optimization outcomes. Optimization resulted in a reduction of overall energy consumption from 975 MJ/m2/year to 729 MJ/m2/year, demonstrating that the BIM model is 25% more efficient than the actual building envelope. The sustainable design alternative achieves a 36.84% savings in lifecycle energy costs. The findings accentuate the need for adopting passive designs to improve energy efficiency, cost, and sustainability.