Jun Zhu

Dr. Jun Zhu

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YLYinxiao Lu
Yinxiao Lu
JZJun Zhu
Jun Zhu
WCWen-Ming Chen
Wen-Ming Chen
XMXin Ma
Xin Ma
Adaptive gait-event detection is essential for intelligent and autonomous control of walking assistive devices. Inertial measurement units (IMUs) based algorithms have been widely adopted but mostly suffered from technical limitations, such as time-delays and/or calculation burden, diverse gait parameters involving different speeds, and other factors in real-world applications. Those can lead to the mismatching of gait between the wearer and the device, further affecting wearing comfort and safety. To reduce the delay and improve the robustness of gait-event detection for knee assistive devices, a lightweight adaptive gait detection method based on an onboard machine learning approach is developed and preliminarily evaluated in this work. The method consists of a two-level algorithm working independently of each other. The first-level algorithm outputs the current detection results at the frequency of 100 Hz, and the second-level algorithm trains and updates the parameters of the gait model for detection every 10 seconds. A total of six events were detected in real-time on a portable Raspberry Pi with two IMUs on thigh and foot, including two specific knee-related events for eliminating detection delay with heel strike and toe off phases in walking. The proposed algorithm exhibits consistently high-performance scores (F1-score of events ≥ 0.92) and early detection capability (≤ 39 ± 22ms) at different walking speeds, in particular, the event prediction for heel strike and toe off were about 77 ± 10ms and 141 ± 10ms in advance, respectively. Given the simple and convenient hardware requirements, this method is especially suitable for intelligent knee assistive device applications.

20 April 2024 in Heliyon
Verified
Journal Article
Open access
LWLongyan Wu
Longyan Wu
RHRan Huang
Ran Huang
LTLisheng Tang
Lisheng Tang
XNXinyi Ning
Xinyi Ning
JZJun Zhu
Jun Zhu
XMXin Ma
Xin Ma
The in-situ mechanical characterization of elastomers is not highly regarded due to the existence of a well-established set of sample-based standard tests for research and industry. However, there are certain situations or materials, like biological soft tissue, where an in-situ approach is necessary due to the impossibility of sampling from a living body. We have developed a dynamic mechanical analysis (DMA)-like device to approach in-vivo and in-situ multidimensional stress-strain properties of human plantar soft tissues. This work elucidates the operational mechanism of the novel measurement, with the definition of a new set of moduli, test standardization and protocol. Exploratory results of a volunteer's living plantar, silica rubber samples are presented with well preciseness and consistence as expected.

18 October 2023 in Electronics
Verified
Journal Article
Open access
PDF file
YLYinxiao Lu
Yinxiao Lu
JZJun Zhu
Jun Zhu
WCWen-Ming Chen
Wen-Ming Chen
XMXin Ma
Xin Ma
In this work, a lightweight adaptive hybrid gait detection method with two inertial measurement units (IMUs) on the foot and thigh was developed and preliminarily evaluated. An adaptive detection algorithm is used to eliminate the pre-training phase and to modify parameters according to the changes within a walking trial using an adaptive two-level architecture. The present algorithm has a two-layer structure: a real-time detection algorithm for detecting the current gait pattern and events at 100 Hz., and a short-time online training layer for updating the parameters of gait models for each gait pattern. Three typical walking patterns, including level-ground walking (LGW), stair ascent (SA), and stair descent (SD), and four events/sub-phases of each pattern, can be detected on a portable Raspberry-Pi platform with two IMUs on the thigh and foot in real-time. A preliminary algorithm test was implemented with healthy subjects in common indoor corridors and stairs. The results showed that the on-board model training and event decoding processes took 20 ms and 1 ms, respectively. Motion detection accuracy was 97.8% for LGW, 95.6% for SA, and 97.1% for SD. F1-scores for event detection were over 0.86, and the maximum time delay was steadily below 51 ± 32.4 ms. Some of the events in gait models of SA and SD seemed to be correlated with knee extension and flexion. Given the simple and convenient hardware requirements, this method is suitable for knee assistive device applications.

31 August 2025
Verified
Book Chapter
Closed access
PDF file
COChuanyun Ouyang
Chuanyun Ouyang
LCLiming Cai
Liming Cai
SYShuhao Yan
Shuhao Yan
TZTianxiang Zhang
Tianxiang Zhang
JZJun Zhu
Jun Zhu
HLHui Liu
Hui Liu