kerry E kelly

Dr. kerry E kelly

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Environmental Pollution
Verified
Journal Article
Closed access
KKkerry E kelly
kerry E kelly
JWJ. Whitaker
J. Whitaker
APA. Petty
A. Petty
CWC. Widmer
C. Widmer
ADA. Dybwad
A. Dybwad
ABA. Butterfield
A. Butterfield

25 March 2004 in Environmental Science & Technology
Verified
Journal Article
Closed access
BZB. Zielinska
B. Zielinska
JSJ. Sagebiel
J. Sagebiel
WAW. P. Arnott
W. P. Arnott
CRC. F. Rogers
C. F. Rogers
KKkerry E kelly
kerry E kelly
GPG. Palmer
G. Palmer

24 May 2023 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
KKKamaljeet Kaur
Kamaljeet Kaur
KKkerry E kelly
kerry E kelly
As the changing climate expands the extent of arid and semi-arid lands, the number of, severity of, and health effects associated with dust events are likely to increase. However, regulatory measurements capable of capturing dust (PM10, particulate matter smaller than 10 µm in diameter) are sparse, sparser than measurements of PM2.5 (PM smaller than 2.5 µm in diameter). Although low-cost sensors could supplement regulatory monitors, as numerous studies have shown for PM2.5 concentrations, most of these sensors are not effective at measuring PM10 despite claims by sensor manufacturers. This study focuses on the Salt Lake Valley, adjacent to the Great Salt Lake, which recently reached historic lows exposing 1865 km2 of dry lake bed. It evaluated the field performance of the Plantower PMS5003, a common low-cost PM sensor, and the Alphasense OPC-N3, a promising candidate for low-cost measurement of PM10, against a federal equivalent method (FEM, beta attenuation) and research measurements (GRIMM aerosol spectrometer model 1.109) at three different locations. During a month-long field study that included five dust events in the Salt Lake Valley with PM10 concentrations reaching 311 µg m−3, the OPC-N3 exhibited strong correlation with FEM PM10 measurements (R2 = 0.865, RMSE = 12.4 µg m−3) and GRIMM (R2 = 0.937, RMSE = 17.7 µg m−3). The PMS exhibited poor to moderate correlations (R2 < 0.49, RMSE = 33–45 µg m−3) with reference or research monitors and severely underestimated the PM10 concentrations (slope < 0.099) for PM10. We also evaluated a PM-ratio-based correction method to improve the estimated PM10 concentration from PMSs. After applying this method, PMS PM10 concentrations correlated reasonably well with FEM measurements (R2 > 0.63) and GRIMM measurements (R2 > 0.76), and the RMSE decreased to 15–25 µg m−3. Our results suggest that it may be possible to obtain better resolved spatial estimates of PM10 concentration using a combination of PMSs (often publicly available in communities) and measurements of PM2.5 and PM10, such as those provided by FEMs, research-grade instrumentation, or the OPC-N3.

1 April 2004 in Combustion and Flame
Verified
Journal Article
Closed access
ABArtur Braun
Artur Braun
FHFrank E. Huggins
Frank E. Huggins
SSSönke Seifert
Sönke Seifert
JIJan Ilavsky
Jan Ilavsky
NSNaresh Shah
Naresh Shah
GHGerald P. Huffman
Gerald P. Huffman

1 October 2011 in Atmospheric Environment
Verified
Journal Article
Closed access
GSGeoffrey D. Silcox
Geoffrey D. Silcox
KKkerry E kelly
kerry E kelly
ECErik T. Crosman
Erik T. Crosman
CWC. David Whiteman
C. David Whiteman
BABruce L. Allen
Bruce L. Allen

1 October 2005 in Carbon
Verified
Journal Article
Closed access
ABArtur Braun
Artur Braun
NSN. Shah
N. Shah
FHF.E. Huggins
F.E. Huggins
KKkerry E kelly
kerry E kelly
ASA. Sarofim
A. Sarofim
GHG.P. Huffman
G.P. Huffman