Electroglottography (EGG) is a technology developed for measuring the vocal fold contact area during human voice production. Although considered subjective and unreliable as a sole diagnostic method, with the correct application of relevant computational methods, it can constitute a most promising non-invasive voice disorder diagnostic tools in a form of a digital vocal tract pathology classifier. The aim of the following study is to gather and evaluate currently existing digital voice quality assessment systems and vocal tract abnormality classification systems that rely on the use of electroglottographic bio-impedance signals. To fully comprehend the findings of this review, first the subject of EGG is introduced. For that, we summarise most relevant existing research on EGG with a particular focus on its application in diagnostics. Then, we move on to the focal point of this work, which is describing and comparing the existing EGG-based digital voice pathology classification systems. With the application of PRISMA model, 13 articles were chosen and analysed in detail. Direct comparison between chosen studies brought us to pivotal conclusions, which have been described in Section 5 of this report. Meanwhile, certain limitations arising from the literature were identified, such as questionable understanding of the nature of EGG bio-impedance signals. The appropriate recommendations for future work were made, including the application of different methods for EGG feature extraction, as well as the need for continuous EGG datasets development containing signals gathered in various conditions and with different equipments.
Background: Heart rate is an essential diagnostic parameter indicating a patient’s condition. The assessment of heart rate is also a crucial parameter in the diagnostics of various sleep disorders, including sleep apnoea, as well as sleep/wake pattern analysis. It is usually measured using an electrocardiograph (ECG)—a device monitoring the electrical activity of the heart using several electrodes attached to a patient’s upper body—or photoplethysmography (PPG). Methods: The following paper investigates an alternative method for heart rate detection and monitoring that operates on tracheal audio recordings. Datasets for this research were obtained from six participants along with ECG Holter (for validation), as well as from fifty participants undergoing a full night polysomnography testing, during which both heart rate measurements and audio recordings were acquired. Results: The presented method implements a digital filtering and peak detection algorithm applied to audio recordings obtained with a wireless sensor using a contact microphone attached in the suprasternal notch. The system was validated using ECG Holter data, achieving over 92% accuracy. Furthermore, the proposed algorithm was evaluated against whole-night polysomnography-derived HR using Bland-Altman’s plots and Pearson’s Correlation Coefficient, reaching the average of 0.82 (0.93 maximum) with 0 BPM error tolerance and 0.89 (0.97 maximum) at ±3 BPM. Conclusions: The results prove that the proposed system serves the purpose of a precise heart rate monitoring tool that can conveniently assess HR during sleep as a part of a home-based sleep disorder diagnostics process.
19 January 2026 in Biomedical Engineering Advances
Sound recording and processing techniques can be used in designing diagnostic solutions for a variety of medical conditions related to the respiratory system. In this spectrum, cough monitoring for chronic or seasonal conditions is a significant medical practice. In this paper, a precise cough identification and monitoring system is presented. The system is utilising a convolutional neural network as a feature extraction algorithm and classification system. Including several functions of loading the audio data into the system and converting it into a set of spectrograms, as well as the pre-segmentation stage function, the model retains its relatively low-complexity, which allows accelerating the learning process, also enhanced using dropout. Due to limited audio data available, the dataset dimension was established at 600 samples, split into two equal-numbered groups - 300 samples of “cough” samples, and 300 of “non-cough” samples. The validation accuracy (thus the percentage of samples labelled correctly by the system during the validation process) yielded over 84%, suggesting that this can be a successful cough detection method for future medical applications and devices, such as potential respiratory system condition diagnostic tool.