Maximilian Lösch

Mr. Maximilian Lösch

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2023 in Applied Thermal Engineering
Verified
Journal Article
Open access
MFMarkus Fallmann
Markus Fallmann
MLMaximilian Lösch
Maximilian Lösch
APAgnes Poks
Agnes Poks
MKMartin Kozek
Martin Kozek

3 May 2025 in Thermal Science and Engineering Progress
Verified
Journal Article
Open access
MLMaximilian Lösch
Maximilian Lösch
SJStefan Jakubek
Stefan Jakubek
MKMartin Kozek
Martin Kozek

6 September 2023 in Energies
Verified
Journal Article
Open access
PDF file
MLMaximilian Lösch
Maximilian Lösch
MFMarkus Fallmann
Markus Fallmann
APAgnes Poks
Agnes Poks
MKMartin Kozek
Martin Kozek
Refrigerated transport by road is essential for the food industry but also contributes significantly to global energy consumption. In particular, last-mile transport, where the doors of the cooling chamber are opened frequently, puts a strain on energy efficiency and temperature control due to the high heat ingress from outside into the cooling chamber. These difficulties can be reduced by thermal energy storage systems, such as secondary loop refrigeration systems, if combined with a sophisticated control scheme. Although the storage capacity of such systems is critical for the overall performance of the cooling system, little research was performed regarding the sizing of the secondary loop thermal storage capacity. Therefore, this article examines the effect of the secondary loop thermal storage capacity on energy consumption and controller performance utilizing closed-loop simulations of a refrigerated vehicle model. Both a mixed-integer model predictive control scheme that can anticipate door openings and a conventional temperature controller are analyzed. An optimal thermal storage capacity of the secondary loop is found with the model predictive controller, whereas the conventional controller cannot exploit the secondary loop and thus shows significantly inferior performance. By using a dimensionless parameter for the thermal storage capacity of the secondary loop, the optimum found can be easily applied to refrigerated vehicles with various cooling chamber dimensions.

14 May 2025 in IEEE Access
Verified
Journal Article
Open access
MLMaximilian Lösch
Maximilian Lösch
SJStefan Jakubek
Stefan Jakubek
MKMartin Kozek
Martin Kozek
Multi-temperature transport systems offer a significant opportunity to improve supply chain efficiency by enabling the simultaneous transport of goods with diverse temperature requirements. However, these systems present critical environmental challenges due to high energy consumption, refrigerant leakage, and the significant amount of goods being damaged or lost due to inadequate temperature control. To address these issues, this study proposes a novel indirect cascade multi-temperature transport system with two temperature-controlled compartments. The design features a compact, well-sealed refrigeration system with reduced refrigerant charge and utilizes the natural refrigerant propane. A nonlinear control strategy based on feedback linearization is introduced to decouple system dynamics and precisely regulate compartment temperatures. Specifically, a two-degree-of-freedom (2DOF) controller, consisting of a feedforward trajectory planning algorithm and a feedback controller, is implemented. Additionally, an optimization-based input transformation allows prioritization of specific compartments when actuator limitations prevent accurate tracking of all compartment temperatures. The control approach was experimentally evaluated on a test bed and compared with a conventional proportional-integral (PI) controller. Across the conducted experiments, the proposed 2DOF control law reduced temperature deviations during normal operation by 40% to 77%, clearly highlighting its quantitative superiority over the conventional approach.