Gian nicola Angotzi

Dr. Gian nicola Angotzi


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
GAGian nicola Angotzi
Gian nicola Angotzi
FBFabio Boi
Fabio Boi
ALAziliz Lecomte
Aziliz Lecomte
EMErmanno Miele
Ermanno Miele
MMMario Malerba
Mario Malerba
LBLuca Berdondini
Luca Berdondini
Large-scale neural recordings with high spatial and temporal accuracy are instrumental to understand how the brain works. To this end, it is of key importance to develop probes that can be conveniently scaled up to a high number of recording channels. Despite recent achievements in complementary metal-oxide semiconductor (CMOS) multi-electrode arrays probes, in current circuit architectures an increase in the number of simultaneously recording channels would significantly increase the total chip area. A promising approach for overcoming this scaling issue consists in the use of the modular Active Pixel Sensor (APS) concept, in which a small front-end circuit is located beneath each electrode. However, this approach imposes challenging constraints on the area of the in-pixel circuit, power consumption and noise. Here, we present an APS CMOS-probe technology for Simultaneous Neural recording that successfully addresses all these issues for whole-array read-outs at 25 kHz/channel from up to 1024 electrode-pixels. To assess the circuit performances, we realized in a 0.18 μm CMOS technology an implantable single-shaft probe with a regular array of 512 electrode-pixels with a pitch of 28 μm. Extensive bench tests showed an in-pixel gain of 45.4 ± 0.4 dB (low pass, F-3 dB = 4 kHz), an input referred noise of 7.5 ± 0.67 μVRMS (300 Hz to 7.5 kHz) and a power consumption <6 μW/pixel. In vivo acute recordings demonstrate that our SiNAPS CMOS-probe can sample full-band bioelectrical signals from each electrode, with the ability to resolve and discriminate activity from several packed neurons both at the spatial and temporal scale. These results pave the way to new generations of compact and scalable active single/multi-shaft brain recording systems.

24 January 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
CFCsaba Forro
Csaba Forro
DCDavide Caron
Davide Caron
GAGian nicola Angotzi
Gian nicola Angotzi
VGVincenzo Gallo
Vincenzo Gallo
Luca BerdondiniLuca Berdondini
Luca Berdondini
Gabriella PanuccioGabriella Panuccio
Gabriella Panuccio
Brain-on-Chip (BoC) biotechnology is emerging as a promising tool for biomedical and pharmaceutical research applied to the neurosciences. At the convergence between lab-on-chip and cell biology, BoC couples in vitro three-dimensional brain-like systems to an engineered microfluidics platform designed to provide an in vivo-like extrinsic microenvironment with the aim of replicating tissue- or organ-level physiological functions. BoC therefore offers the advantage of an in vitro reproduction of brain structures that is more faithful to the native correlate than what is obtained with conventional cell culture techniques. As brain function ultimately results in the generation of electrical signals, electrophysiology techniques are paramount for studying brain activity in health and disease. However, as BoC is still in its infancy, the availability of combined BoC–electrophysiology platforms is still limited. Here, we summarize the available biological substrates for BoC, starting with a historical perspective. We then describe the available tools enabling BoC electrophysiology studies, detailing their fabrication process and technical features, along with their advantages and limitations. We discuss the current and future applications of BoC electrophysiology, also expanding to complementary approaches. We conclude with an evaluation of the potential translational applications and prospective technology developments.

6 August 2014 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GAGian nicola Angotzi
Gian nicola Angotzi
FBFabio Boi
Fabio Boi
SZStefano Zordan
Stefano Zordan
ABAndrea Bonfanti
Andrea Bonfanti
AVAlessandro Vato
Alessandro Vato
A portable 16-channels microcontroller-based wireless system for a bi-directional interaction with the central nervous system is presented in this work. The device is designed to be used with freely behaving small laboratory animals and allows recording of spontaneous and evoked neural activity wirelessly transmitted and stored on a personal computer. Biphasic current stimuli with programmable duration, frequency and amplitude may be triggered in real-time on the basis of the recorded neural activity as well as by the animal behavior within a specifically designed experimental setup. An intuitive graphical user interface was developed to configure and to monitor the whole system. The system was successfully tested through bench tests and in vivo measurements on behaving rats chronically implanted with multi-channels microwire arrays.

30 May 2018 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
GSGiovanni Pietro Seu
Giovanni Pietro Seu
GAGian nicola Angotzi
Gian nicola Angotzi
FBFabio Boi
Fabio Boi
LRLuigi Raffo
Luigi Raffo
Luca BerdondiniLuca Berdondini
Luca Berdondini
PMPaolo Meloni
Paolo Meloni
Microelectrode array (MEA) systems with up to several thousands of recording electrodes and electrical or optical stimulation capabilities are commercially available or described in the literature. By exploiting their submillisecond and micrometric temporal and spatial resolutions to record bioelectrical signals, such emerging MEA systems are increasingly used in neuroscience to study the complex dynamics of neuronal networks and brain circuits. However, they typically lack the capability of implementing real-time feedback between the detection of neuronal spiking events and stimulation, thus restricting large-scale neural interfacing to open-loop conditions. In order to exploit the potential of such large-scale recording systems and stimulation, we designed and validated a fully reconfigurable FPGA-based processing system for closed-loop multichannel control. By adopting a Xilinx Zynq—all-programmable system on chip that integrates reconfigurable logic and a dual-core ARM-based processor on the same device, the proposed platform permits low-latency preprocessing (filtering and detection) of spikes acquired simultaneously from several thousands of electrode sites. To demonstrate the proposed platform, we tested its performances through ex vivo experiments on the mice retina using a state-of-the-art planar high-density MEA that samples 4096 electrodes at 18 kHz and record light-evoked spikes from several thousands of retinal ganglion cells simultaneously. Results demonstrate that the platform is able to provide a total latency from whole-array data acquisition to stimulus generation below 2 ms. This opens the opportunity to design closed-loop experiments on neural systems and biomedical applications using emerging generations of planar or implantable large-scale MEA systems.

1 November 2017 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Open access
MCMarco Crepaldi
Marco Crepaldi
GAGian nicola Angotzi
Gian nicola Angotzi
AMAntonio Maviglia
Antonio Maviglia
FDFrancesco Diotalevi
Francesco Diotalevi
Luca BerdondiniLuca Berdondini
Luca Berdondini
This paper presents an ultralow power asynchronous logic transmitter operating at 1 Gpps that achieves pulse synthesis using a double phase-locked loop (PLL) architecture for applications exploiting large-scale neuronal interfacing with CMOS probes. The 4 GHz center frequency OOK transmitter synthesizes 500 ps duration pulses from a 31.25 MHz crystal oscillator using a cascade of a master and a slave PLL with the latter locked to the former. Both PLLs are implemented with CMOS digital cells and ring oscillator-based VCO. A prototype fabricated in a 130 nm RFCMOS process operates at a measured 5 pJ/pulse energy budget for an active area of 0.04 mm². To generate timing references and packets for high data rate recording devices, the synthesizer core feeds also a logic interface operating at 250 MHz with four 1.2-3.3 V external parallel channels. From reset time, the master-slave PLL combination achieves locking in a measured time of 450 ns, settling is resolved in ~4 μs, and the output pulses across the antenna load are generated with a 3.42 ps RMS jitter standard deviation. The obtained phase noise of a continuous OOK stream at 1 and 4 GHz, 1 MHz offset, is -103 and -93 dBc/Hz, respectively.

29 August 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
FBFabio Boi
Fabio Boi
NPNikolas Perentos
Nikolas Perentos
ALAziliz Lecomte
Aziliz Lecomte
GSGerrit Schwesig
Gerrit Schwesig
SZStefano Zordan
Stefano Zordan
GAGian nicola Angotzi
Gian nicola Angotzi
The advent of implantable active dense CMOS neural probes opened a new era for electrophysiology in neuroscience. These single shank electrode arrays, and the emerging tailored analysis tools, provide for the first time to neuroscientists the neurotechnology means to spatiotemporally resolve the activity of hundreds of different single-neurons in multiple vertically aligned brain structures. However, while these unprecedented experimental capabilities to study columnar brain properties are a big leap forward in neuroscience, there is the need to spatially distribute electrodes also horizontally. Closely spacing and consistently placing in well-defined geometrical arrangement multiple isolated single-shank probes is methodologically and economically impractical. Here, we present the first high-density CMOS neural probe with multiple shanks integrating thousand’s of closely spaced and simultaneously recording microelectrodes to map neural activity across 2D lattice. Taking advantage from the high-modularity of our electrode-pixels-based SiNAPS technology, we realized a four shanks active dense probe with 256 electrode-pixels/shank and a pitch of 28 µ m, for a total of 1024 simultaneously recording channels. The achieved performances allow for full-band, whole-array read-outs at 25 kHz/channel, show a measured input referred noise in the action potential band (300-7000 Hz) of 6.5 ± 2.1 µ V RMS , and a power consumption 6 mm 2 , spanning cortical, hippocampal and thalamic regions. High-density 2D array enables combining large population unit recording across distributed networks with precise intra- and interlaminar/nuclear mapping of the oscillatory dynamics. These results pave the way to a new generation of high-density and extremely compact multi-shanks CMOS-probes with tunable layouts for electrophysiological mapping of brain activity at the single-neurons resolution.