Jonathan P Rothstein

Prof. Jonathan P Rothstein

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

18 December 2009 in Rheologica Acta
Verified
Journal Article
Closed access
PDF file
EWErica E. Bischoff White
Erica E. Bischoff White
MCManoj Chellamuthu
Manoj Chellamuthu
JRJonathan P Rothstein
Jonathan P Rothstein

7 May 2009 in Rheologica Acta
Verified
Journal Article
Closed access
PDF file
EMErik Miller
Erik Miller
CCChristian Clasen
Christian Clasen
JRJonathan P Rothstein
Jonathan P Rothstein

27 July 2014 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
DSDong Song
Dong Song
RDRobert J. Daniello
Robert J. Daniello
JRJonathan P Rothstein
Jonathan P Rothstein

9 December 2021 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ANAditi R. Naik
Aditi R. Naik
YZYiliang Zhou
Yiliang Zhou
ADAnita A. Dey
Anita A. Dey
DAD. Leonardo González Arellano
D. Leonardo González Arellano
UOUzodinma Okoroanyanwu
Uzodinma Okoroanyanwu
JWJames J. Watkins
James J. Watkins
Wearable sweat biosensors offer compelling opportunities for improved personal health monitoring and non-invasive measurements of key biomarkers. Inexpensive device fabrication methods are necessary for scalable manufacturing of portable, disposable, and flexible sweat sensors. Furthermore, real-time sweat assessment must be analyzed to validate measurement reliability at various sweating rates. Here, we demonstrate a “smart bandage” microfluidic platform for cortisol detection and continuous glucose monitoring integrated with a synthetic skin. The low-cost, laser-cut microfluidic device is composed of an adhesive-based microchannel and solution-processed electrochemical sensors fabricated from inkjet-printed graphene and silver solutions. An antibody-derived cortisol sensor achieved a limit of detection of 10 pM and included a low-voltage electrowetting valve, validating the microfluidic sensor design under typical physiological conditions. To understand effects of perspiration rate on sensor performance, a synthetic skin was developed using soft lithography to mimic human sweat pores and sweating rates. The enzymatic glucose sensor exhibited a range of 0.2 to 1.0 mM, a limit of detection of 10 μM, and reproducible response curves at flow rates of 2.0 μL min−1 and higher when integrated with the synthetic skin, validating its relevance for human health monitoring. These results demonstrate the potential of using printed microfluidic sweat sensors as a low-cost, real-time, multi-diagnostic device for human health monitoring.

28 August 2018 in Journal of Rheology
Verified
Journal Article
Closed access
PDF file
SSSamrat Sur
Samrat Sur
JRJonathan P Rothstein
Jonathan P Rothstein
The large extensional viscosity of dilute polymer solutions has been shown to dramatically delay the breakup of jets into drops. For low shear viscosity solutions, the jet breakup is initially governed by a balance of inertial and capillary stresses before transitioning to a balance of viscoelastic and capillary stresses at later times. This transition occurs at a critical time when the radius decay dynamics shift from a 2/3 power law to an exponential decay as the increasing deformation rate imposed on the fluid filament results in large molecular deformations and rapid crossover into the elasto-capillary regime. By experimental fits of the elasto-capillary thinning diameter data, a relaxation time of less than 100 μs has been successfully measured. In this paper, we show that, with a better understanding of the transition from the inertia-capillary to the elasto-capillary breakup regime, relaxation times close to 10 μs can be measured with the relaxation time resolution limited only by the frame rate and spatial resolution of the high speed camera. In this paper, the dynamics of drop formation and pinch-off are presented using dripping onto substrate capillary breakup extensional rheometry (CaBER-DoS) for a series of dilute solutions of polyethylene oxide (PEO) in water and in a viscosified water and glycerin mixture. Four different molecular weights between 100 k and 1 M g/mol were studied with varying solution viscosities between 1 and 22 mPa s and at concentrations between 0.004 and 0.5 times the overlap concentration, c*. The dependence of the relaxation time and extensional viscosity on these varying parameters was studied and compared to the predictions of dilute solution theory while simultaneously searching for the lower limit in solution elasticity that can be detected. For PEO in water, this limit was found to be a fluid with a relaxation time of roughly 20 μs. These results confirm that CaBER-DoS can be a powerful technique characterizing the rheology of a notoriously difficult material to quantify, namely, low viscosity inkjet printer inks.