Salman Aatif

Dr. Salman Aatif


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
XYXiaowei Yang
Xiaowei Yang
Haitao HuHaitao Hu
Haitao Hu
YGYinbo Ge
Yinbo Ge
SASalman Aatif
Salman Aatif
ZHZhengyou He
Zhengyou He
SGShibin Gao
Shibin Gao
Due to the development of advanced power electronic techniques, voltage-source-converter-based medium voltage dc (MVDC) traction power supply system (VSC-based MVDC TPSS) could be an alternative supply solution for high-speed railways (HSRs) in the future. The distributed configuration of the MVDC system, along with dynamic load and catenary resistance, makes the control of such system a real challenge. In this paper, an improved droop control method is proposed to obtain a better performance of system operation for the specific supply environment without any communication links. The proposed control scheme can eliminate the voltage deviation due to droop action and improve catenary network voltage control dynamics by using voltage-shifting and load current feedforward control approaches simultaneously. Additionally, the detailed model of the proposed control scheme is derived and the stability in the case of moving load is critically tested. Finally, a simulation model based on MATLAB/Simulink and an experimental prototype have been established to validate the effectiveness of the proposed control method.

13 July 2021 in Railway Engineering Science
Verified
Journal Article
Open access
PDF file
SASalman Aatif
Salman Aatif
Haitao HuHaitao Hu
Haitao Hu
FRFezan Rafique
Fezan Rafique
ZHZhengyou He
Zhengyou He
In contrast to the conventional direct current railway electrification system (DC-RES), the medium voltage direct current (MVDC)-RES is considered promising for long-distance high-speed corridors. In the MVDC-RES, traction substations (TSSs) are placed much farther and train loads are much heavier than in the conventional DC-RES. Hence, the MVDC-RES brings a drastic change in catenary voltage, TSS spacing, and train loading, which affects rail potential and stray current. In this connection, this work performs some significant quantitative analysis of rail potential and stray current in the MVDC-RES environment. An MVDC simulation model is proposed and different grounding schemes are analyzed for a single-train and two TSSs scenario as well as for a multi-train multi-TSS scenario. According to the simulation and analysis, the maximum values of rail potential and stray current at MVDC-RES distances and the maximum safe distance between adjacent TSSs are determined.

3 January 2019 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
SASalman Aatif
Salman Aatif
Haitao HuHaitao Hu
Haitao Hu
XYXiaowei Yang
Xiaowei Yang
YGYinbo Ge
Yinbo Ge
ZHZhengyou He
Zhengyou He
SGShibin Gao
Shibin Gao
The share of voltage source converter (VSC) technology is increasing in conventional power systems, and it is penetrating into specific transportation systems such as electric vehicles, railways, and ships. Researchers are identifying feasible methods to improve the performance of railway electrification systems (RESs) by utilizing VSC-based medium-voltage direct current (MVDC) railways. The continuous motion of electric trains makes the catenary resistance a variable quantity, as compared to the traction substation (TSS), and affects the current-sharing behavior of the system. A modified droop control technique is proposed in this paper for VSC-based MVDC RES to provide more effective current-sharing while maintaining catenary voltages above the minimum allowable limit. The droop coefficient is selected through an exponential function based on the ratio between the concerned TSS current and the system average current. This enables small adjustments of droop values in less concerning marginal current deviations, and provides higher droop adjustments for large current deviations. Meanwhile, the catenary voltages are regulated by considering the voltage data at the midpoint between two TSSs, which experiences the lowest voltages owing to the larger distance from the TSSs. The proposed techniques are validated via simulations and experiments.

4 June 2025 in Ad Hoc Networks
Verified
Journal Article
Closed access
Ayaz AhmadAyaz Ahmad
Ayaz Ahmad
FAFawad Ahmad
Fawad Ahmad
SASalman Aatif
Salman Aatif
AAAdel Aldalbahi
Adel Aldalbahi

18 February 2015 in International Journal of Computer Applications
Verified
Journal Article
Closed access
SASalman Aatif
Salman Aatif
MAMuhammad Naeem Arbab
Muhammad Naeem Arbab

1 October 2014
Verified
Conference Paper
Closed access
SASalman Aatif
Salman Aatif
NANaeem Arbab
Naeem Arbab
The serious issue of power shortages in developing countries like Pakistan leads to the search for developing renewable, economical and environment friendly re.sources of energy. Generating electricity through Waste To Energy (WTE) Plants can be a good choice for densely populated cities and is becoming popular in Asia as an economical and environment friendly technology. In this paper, capacity of Solid Waste Fueled Power Plant (SWF.PP) for city of Peshawar, Pakistan has been djscussed and for its effective results of waste incineration and Power generation a precise estimation of waste quantity collected its characteristics and ultimate power generation has been analyzed.