Shohei Yamamura

Dr. Shohei Yamamura

Health Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 2217-14 Hayashi-cho, Takamatsu, Japan

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2009 in The Analyst
Verified
Journal Article
Closed access
PDF file
MTMasatoshi Tsukamoto
Masatoshi Tsukamoto
STShu Taira
Shu Taira
SYShohei Yamamura
Shohei Yamamura
YMYasutaka Morita
Yasutaka Morita
NNNaoki Nagatani
Naoki Nagatani
Eiichi TamiyaEiichi Tamiya
Eiichi Tamiya
We generated an aqueous two-phase laminar flow in a microfluidic chip and used the system to isolate leukocyte and erythrocyte cells from whole blood cells. The microfluidic system reduced the effect of gravity in the aqueous two-phase system (ATPS). Poly(ethylene glycol) (PEG) and dextran (Dex) solutions were used as the two phases, and the independent flow rates of the solutions were both 2 µL/min. When hydrophobic and hydrophilic polystyrene beads were introduced into the microfluidic device, the hydrophilic beads moved to the Dex layer and the hydrophobic beads to the interface between the two phases. In the case of living cells, Jurkat cells and erythrocytes moved more efficiently to the PEG and Dex layers, respectively, than they move in a conventional ATPS. When whole blood cells were inserted into the microfluidic chip, leukocytes could be separated from erythrocytes because erythrocytes moved to the Dex layer while leukocytes remained outside of this layer in the microfluidic system. The reported microfluidic chip for the whole blood cell separation can effectively be integrated into a Micro Total Analysis System designed for cell-based clinical, forensic, and environmental analyses.

13 August 2013 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
ESEdakkattuparambil Sidharth Shibu
Edakkattuparambil Sidharth Shibu
SSSakiko Sugino
Sakiko Sugino
KOKenji Ono
Kenji Ono
HSHironobu Saito
Hironobu Saito
ANAyama Nishioka
Ayama Nishioka
VBVasudevanpillai Biju
Vasudevanpillai Biju

13 October 2010 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SYShouki Yatsushiro
Shouki Yatsushiro
SYShohei Yamamura
Shohei Yamamura
YYYuka Yamaguchi
Yuka Yamaguchi
YSYasuo Shinohara
Yasuo Shinohara
ETEiichi Tamiya
Eiichi Tamiya
MKMasatoshi Kataoka
Masatoshi Kataoka
Malaria is one of the major human infectious diseases in many endemic countries. For prevention of the spread of malaria, it is necessary to develop an early, sensitive, accurate and conventional diagnosis system. A cell microarray chip was used to detect for malaria-infected erythrocytes. The chip, with 20,944 microchambers (105 µm width and 50 µm depth), was made from polystyrene, and the formation of monolayers of erythrocytes in the microchambers was observed. Cultured Plasmodium falciparum strain 3D7 was used to examine the potential of the cell microarray chip for malaria diagnosis. An erythrocyte suspension in a nuclear staining dye, SYTO 59, was dispersed on the chip surface, followed by 10 min standing to allow the erythrocytes to settle down into the microchambers. About 130 erythrocytes were accommodated in each microchamber, there being over 2,700,000 erythrocytes in total on a chip. A microarray scanner was employed to detect any fluorescence-positive erythrocytes within 5 min, and 0.0001% parasitemia could be detected. To examine the contamination by leukocytes of purified erythrocytes from human blood, 20 µl of whole blood was mixed with 10 ml of RPMI 1640, and the mixture was passed through a leukocyte isolation filter. The eluted portion was centrifuged at 1,000×g for 2 min, and the pellet was dispersed in 1.0 ml of medium. SYTO 59 was added to the erythrocyte suspension, followed by analysis on a cell microarray chip. Similar accommodation of cells in the microchambers was observed. The number of contaminating leukocytes was less than 1 on a cell microarray chip. The potential of the cell microarray chip for the detection of malaria-infected erythrocytes was shown, it offering 10–100 times higher sensitivity than that of conventional light microscopy and easy operation in 15 min with purified erythrocytes.

31 October 2016 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
KTKeiko TAWA
Keiko TAWA
SYShohei Yamamura
Shohei Yamamura
CSChisato Sasakawa
Chisato Sasakawa
ISIzumi Shibata
Izumi Shibata
MKMasatoshi Kataoka
Masatoshi Kataoka

1 September 2016 in EBioMedicine
Verified
Journal Article
Open access
TSTakeshi Sawada
Takeshi Sawada
JAJungo Araki
Jungo Araki
TYToshinari Yamashita
Toshinari Yamashita
MMManami Masubuchi
Manami Masubuchi
TCTsuneko Chiyoda
Tsuneko Chiyoda
FKFumiaki Koizumi
Fumiaki Koizumi
Various types of circulating tumor cell (CTC) detection systems have recently been developed that show a high CTC detection rate. However, it is a big challenge to find a system that can provide better prognostic value than CellSearch in head-to-head comparison. We have developed a novel semi-automated CTC enumeration system (fluidic cell microarray chip system, FCMC) that captures CTC independently of tumor-specific markers or physical properties. Here, we compared the CTC detection sensitivity and the prognostic value of FCMC with CellSearch in breast cancer patients. FCMC was validated in preclinical studies using spike-in samples and in blood samples from 20 healthy donors and 22 breast cancer patients in this study. Using spike-in samples, a statistically higher detection rate (p=0.010) of MDA-MB-231 cells and an equivalent detection rate (p=0.497) of MCF-7 cells were obtained with FCMC in comparison with CellSearch. The number of CTC detected in samples from patients that was above a threshold value as determined from healthy donors was evaluated. The CTC number detected using FCMC was significantly higher than that using CellSearch (p=0.00037). CTC numbers obtained using either FCMC or CellSearch had prognostic value, as assessed by progression free survival. The hazard ratio between CTC+ and CTC- was 4.229 in CellSearch (95% CI, 1.31 to 13.66; p=0.01591); in contrast, it was 11.31 in FCMC (95% CI, 2.245 to 57.0; p=0.000244). CTC detected using FCMC, like the CTC detected using CellSearch, have the potential to be a strong prognostic factor for cancer patients.

9 January 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KAKaori Abe
Kaori Abe
YHYoshiko Hashimoto
Yoshiko Hashimoto
SYShouki Yatsushiro
Shouki Yatsushiro
SYShohei Yamamura
Shohei Yamamura
MBMika Bando
Mika Bando
MKMasatoshi Kataoka
Masatoshi Kataoka
Sandwich enzyme-linked immunosorbant assay (ELISA) using a 96-well plate is frequently employed for clinical diagnosis, but is time-and sample-consuming. To overcome these drawbacks, we performed a sandwich ELISA on a microchip. The microchip was made of cyclic olefin copolymer with 4 straight microchannels. For the construction of the sandwich ELISA for interleukin-6 (IL-6) or tumor necrosis factor-α (TNF-α), we used a piezoelectric inkjet printing system for the deposition and fixation of the 1st anti-IL-6 antibody or 1st anti-TNF-α antibody on the surface of the each microchannel. After the infusion of 2 µl of sample to the microchannel and a 20 min incubation, 2 µl of biotinylated 2nd antibody for either antigen was infused and a 10 min incubation. Then 2 µl of avidin-horseradish peroxidase was infused; and after a 5 min incubation, the substrate for peroxidase was infused, and the luminescence intensity was measured. Calibration curves were obtained between the concentration and luminescence intensity over the range of 0 to 32 pg/ml (IL-6: R2 = 0.9994, TNF-α: R2 = 0.9977), and the detection limit for each protein was 0.28 pg/ml and 0.46 pg/ml, respectively. Blood IL-6 and TNF-α concentrations of 5 subjects estimated from the microchip data were compared with results obtained by the conventional method, good correlations were observed between the methods according to linear regression analysis (IL-6: R2 = 0.9954, TNF-α: R2 = 0.9928). The reproducibility of the presented assay for the determination of the blood IL-6 and TNF-α concentration was comparable to that obtained with the 96-well plate. Simultaneous detection of blood IL-6 and TNF-α was possible by the deposition and fixation of each 1st antibody on the surface of a separate microchannel. This assay enabled us to determine simultaneously blood IL-6 and TNF-α with accuracy, satisfactory sensitivity, time saving ability, and low consumption of sample and reagents, and will be applicable to clinic diagnosis.