Jarno Huhtanen

Mr. Jarno Huhtanen


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JHJarno Huhtanen
Jarno Huhtanen
MNMikko Nyman
Mikko Nyman
DDDorin Doncenco
Dorin Doncenco
MHMaral Hamedian
Maral Hamedian
DKDavis Kawalya
Davis Kawalya
MJMojtaba Jafaritadi
Mojtaba Jafaritadi
Joint effusion due to elbow fractures are common among adults and children. Radiography is the most commonly used imaging procedure to diagnose elbow injuries. The purpose of the study was to investigate the diagnostic accuracy of deep convolutional neural network algorithms in joint effusion classification in pediatric and adult elbow radiographs. This retrospective study consisted of a total of 4423 radiographs in a 3-year period from 2017 to 2020. Data was randomly separated into training (n = 2672), validation (n = 892) and test set (n = 859). Two models using VGG16 as the base architecture were trained with either only lateral projection or with four projections (AP, LAT and Obliques). Three radiologists evaluated joint effusion separately on the test set. Accuracy, precision, recall, specificity, F1 measure, Cohen’s kappa, and two-sided 95% confidence intervals were calculated. Mean patient age was 34.4 years (1–98) and 47% were male patients. Trained deep learning framework showed an AUC of 0.951 (95% CI 0.946–0.955) and 0.906 (95% CI 0.89–0.91) for the lateral and four projection elbow joint images in the test set, respectively. Adult and pediatric patient groups separately showed an AUC of 0.966 and 0.924, respectively. Radiologists showed an average accuracy, sensitivity, specificity, precision, F1 score, and AUC of 92.8%, 91.7%, 93.6%, 91.07%, 91.4%, and 92.6%. There were no statistically significant differences between AUC's of the deep learning model and the radiologists (p value > 0.05). The model on the lateral dataset resulted in higher AUC compared to the model with four projection datasets. Using deep learning it is possible to achieve expert level diagnostic accuracy in elbow joint effusion classification in pediatric and adult radiographs. Deep learning used in this study can classify joint effusion in radiographs and can be used in image interpretation as an aid for radiologists.

9 June 2025 in Emergency Radiology
Verified
Journal Article
Open access
PDF file
JHJarno Huhtanen
Jarno Huhtanen
MNMikko Nyman
Mikko Nyman
RSRoberto Blanco Sequeiros
Roberto Blanco Sequeiros
SKSeppo K. Koskinen
Seppo K. Koskinen
TPTomi K. Pudas
Tomi K. Pudas
JHJussi Hirvonen
Jussi Hirvonen
Purpose: Missed fractures are the primary cause of interpretation errors in emergency radiology, and artificial intelligence has recently shown great promise in radiograph interpretation. This study compared the diagnostic performance of two AI algorithms, BoneView and RBfracture, in detecting traumatic abnormalities (fractures and dislocations) in MSK radiographs. Methods: AI algorithms analyzed 998 radiographs (585 normal, 413 abnormal), against the consensus of two MSK specialists. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and interobserver agreement (Cohen’s Kappa) were calculated. 95% confidence intervals (CI) assessed robustness, and McNemar’s tests compared sensitivity and specificity between the AI algorithms. Results: BoneView demonstrated a sensitivity of 0.893 (95% CI: 0.860–0.920), specificity of 0.885 (95% CI: 0.857–0.909), PPV of 0.846, NPV of 0.922, and accuracy of 0.889. RBfracture demonstrated a sensitivity of 0.872 (95% CI: 0.836–0.901), specificity of 0.892 (95% CI: 0.865–0.915), PPV of 0.851, NPV of 0.908, and accuracy of 0.884. No statistically significant differences were found in sensitivity (p = 0.151) or specificity (p = 0.708). Kappa was 0.81 (95% CI: 0.77–0.84), indicating almost perfect agreement between the two AI algorithms. Performance was similar in adults and children. Both AI algorithms struggled more with subtle abnormalities, which constituted 66% and 70% of false negatives but only 20% and 18% of true positives for the two AI algorithms, respectively (p < 0.001). Conclusions: BoneView and RBfracture exhibited high diagnostic performance and almost perfect agreement, with consistent results across adults and children, highlighting the potential of AI in emergency radiograph interpretation.

13 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
JHJarno Huhtanen
Jarno Huhtanen
MNMikko Nyman
Mikko Nyman
RSRoberto Blanco Sequeiros
Roberto Blanco Sequeiros
SKSeppo K. Koskinen
Seppo K. Koskinen
TPTomi K. Pudas
Tomi K. Pudas
JHJussi Hirvonen
Jussi Hirvonen
(1) Background: The aim of this study was to compare the competence in appendicular trauma radiograph image interpretation between radiology specialists and residents. (2) Methods: In this multicenter retrospective cohort study, we collected radiology reports from radiology specialists (N = 506) and residents (N = 500) during 2018–2021. As a reference standard, we used the consensus of two subspecialty-level musculoskeletal (MSK) radiologists, who reviewed all original reports. (3) Results: A total of 1006 radiograph reports were reviewed by the two subspecialty-level MSK radiologists. Of the 1006 radiographs, 41% were abnormal. In total, 67 radiographic findings were missed (6.7%) and 32 findings were overcalled (3.2%) in the original reports. The sensitivity, specificity, positive predictive value, and negative predictive value were 0.86, 0.92, 0.88, and 0.91, respectively. There were no statistically significant differences between radiology specialists’ and residents’ competence in interpretation (p = 0.44). However, radiology specialists reported more subtle cases than residents did (p = 0.04). There were no statistically significant differences between errors made in the morning, evening, or night shifts (p = 0.57). (4) Conclusions: This study found a lack of major discrepancies between radiology specialists and residents in radiograph interpretation, although there were differences between MSK regions and in subtle or obvious radiographic findings. In addition, missed findings found in this study often affected patient treatment. Finally, there are MSK regions where the sensitivity or specificity is below 90%, and these should raise concerns and highlight the need for double reading and should be taken into consideration in radiology education.

24 December 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
JHJarno Huhtanen
Jarno Huhtanen
MNMikko Nyman
Mikko Nyman
RSRoberto Blanco Sequeiros
Roberto Blanco Sequeiros
SKSeppo K. Koskinen
Seppo K. Koskinen
TPTomi K. Pudas
Tomi K. Pudas
JHJussi Hirvonen
Jussi Hirvonen
Regarding our publication, entitled “Discrepancies between Radiology Specialists and Residents in Fracture Detection from Musculoskeletal Radiographs”

8 May 2026 in European Journal of Radiology Open
Verified
Journal Article
Open access
JHJarno Huhtanen
Jarno Huhtanen
MNMikko Nyman
Mikko Nyman
RSRoberto Blanco Sequeiros
Roberto Blanco Sequeiros
SKSeppo K. Koskinen
Seppo K. Koskinen
TPTomi K. Pudas
Tomi K. Pudas
JHJussi Hirvonen
Jussi Hirvonen
Knee joint effusion might indicate injury even without bony changes. Automated detection from radiographs could improve the sensitivity of AI algorithms. To compare two commercially available AI algorithms, BoneView and RBfracture, in detecting knee joint effusion. This retrospective study collected 123 lateral knee radiographs. Detection of knee joint effusion by both AI algorithms was compared with two board-certified radiologists with arbitration. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and interobserver agreement (Cohen’s Kappa) were calculated. 95% confidence intervals (CI) assessed robustness. McNemar’s tests compared sensitivity and specificity between AI algorithms. Knee joint effusion was present in 56% of radiographs. BoneView demonstrated a sensitivity of 0.42 (95% CI: 0.31–0.54), specificity of 1.00 (95% CI: 0.93–1.00), PPV of 1.00 (95% CI: 0.88–1.00), NPV of 0.57 (95% CI: 0.47–0.67), and accuracy of 0.68 (95% CI: 0.59–0.75). RBfracture demonstrated a sensitivity of 0.75 (95% CI: 0.64–0.84), specificity of 0.91 (95% CI: 0.80–0.96), PPV of 0.91 (95% CI: 0.81–0.96), NPV of 0.74 (95% CI: 0.63–0.83), and accuracy of 0.82 (95% CI: 0.74–0.88). Cohen’s Kappa was 0.49 (95% CI: 0.35–0.63), indicating moderate agreement between the two AI algorithms. Adding knee joint effusion detection to fracture/dislocation predictions improved sensitivity. Two commercially available AI algorithms demonstrated different operating points for knee joint effusion detection: BoneView achieved high specificity, while RBfracture achieved higher sensitivity. Combining injury and effusion predictions increased sensitivity at the cost of specificity.