Qiaolin Li

Dr. Qiaolin Li


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SSShuonan Shan
Shuonan Shan
JLJingwen Li
Jingwen Li
PLPeiyuan Liu
Peiyuan Liu
QLQiaolin Li
Qiaolin Li
XWXiaohao Wang
Xiaohao Wang
XLXinghui Li
Xinghui Li
Most existing multi-channel spectrometers are constructed by physically stacking single-channel spectrometers, resulting in their large size, high weight, and limited number of channels. Therefore, their miniaturization is urgently needed. In this paper, a microlens array grating is designed for miniature multi-channel spectrometers. A transmissive element integrating microlens arrays and gratings, the MLAG, enables simultaneous focusing and dispersion. Using soft lithography, the MLAG was fabricated with a deviation of less than 2.2%. The dimensions are 10 mm × 10 mm × 4 mm with over 2000 available units. The MLAG spectrometer operates in the 400–700 nm wavelength range with a resolution of 6 nm. Additionally, the designed MLAG multi-channel spectrometer is experimentally verified to have independently valid cells that can be used in multichannel spectrometers. The wavelength position repeatability deviation of each cell is about 0.5 nm, and the repeatability of displacement measurements by the chromatic confocal sensor with the designed MLAG multi-channel spectrometer is less than 0.5 μm.

13 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
BWBorong Wu
Borong Wu
CZChuang Zeng
Chuang Zeng
QLQiaolin Li
Qiaolin Li
To investigate the high-accuracy roundness metrology of a needle roller 1.5 mm in diameter and 5.8 mm in length using the stitching linear scan method, a ruby ball stylus with a tip radius of 150 μm and a diamond stylus with a tip radius of 2 μm were employed to perform experiments under the same conditions. The precision coordinate data, derived from the needle roller’s cross-sectional circumference, were segmented into uniform eighths, each scanned with the stylus of a roughness measuring machine. The roundness profile of the needle roller was obtained by stitching the arc profiles, which were characterized according to the precision coordinate data of the arcs. The cross-correlation function, Euclidean distance, residual sum of squares, position error, and curvature of the measured arcs were used to evaluate the results, which can reflect the performance of the stylus. A comparison of the results obtained using the ruby ball stylus versus the diamond stylus demonstrates the ruby ball stylus’ greater suitability for use in the roundness metrology of the needle roller bearing examined in this paper.

9 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JZJiali Zhao
Jiali Zhao
LZLiang Zhang
Liang Zhang
DWDan Wu
Dan Wu
BSBobo Shen
Bobo Shen
QLQiaolin Li
Qiaolin Li
A stitching linear scan method is proposed for roundness and diameter measurement of small cylindrical workpieces instead of the conventional rotary scan method due to the crucial alignments of eccentricity and inclination. To verify the reliability of the proposed method, by which the coordinates of the cross-sectional circle of a small cylinder is divided into several equal parts to be obtained and reconstructed, the diameter and roundness measurement uncertainties of the small cylinders with a diameter 1.5 mm are evaluated to be 0.047 μm and 0.095 μm, respectively, which can meet the uncertainty target of 0.1 μm. To investigate the measurable dimension by the proposed method, measurement uncertainty analysis of the small cylinders with various dimensions has been conducted according to the previous evaluation, since all the procedures are the same except for the uncertainty of X coordinates, which changes with the measured dimension’s change. The results show that the small cylinders with a diameter range from 0.01 mm to 50 mm can be measured by the proposed method when the position error θZ is reduced to the corresponding value. There is no measuring limitation set by the proposed model theoretically in the case of θX = θZ = 0.1°, while the machine has a measuring limitation.

11 October 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KHKaiheng Huang
Kaiheng Huang
QLQiaolin Li
Qiaolin Li
KZKaixiong Zhu
Kaixiong Zhu
BCBaihan Chen
Baihan Chen
Xiang QianXiang Qian
Xiang Qian
XLXinghui Li
Xinghui Li
A through-transmission ultrasonic method is proposed to address limitations in conventional ultrasonic reflection methods for non-destructive testing of ferrite tiles. The method utilizes a dual-probe configuration on both sides of the test piece to measure ultrasonic transmission signals, overcoming issues related to blind zones and orientation limitations in pulse-echo reflection methods. This method demonstrates excellent capabilities for full inspection of internal and external defects in ferrite tiles. Physical field finite element simulations were conducted to analyze detection capabilities and a transmissive testing system is developed based on the simulation results. Experimental validation was performed on artificially manufactured quantified defect samples in aluminum alloy, and the same testing system was applied to evaluate ferrite tile samples. The results confirmed the effectiveness of the system in distinguishing defective (NG) signals from normal defect-free (OK) signals, with a recall rate of at least 95% on samples of various sizes up to 0.1 mm. This research provides insights for quality control and defect detection technology in ferrite tiles.