Zahra Tajbakhsh

Dr. Zahra Tajbakhsh

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2017 in Cornea
Verified
Journal Article
Closed access
PDF file
MYMasood Yasemi
Masood Yasemi
MNMohammad Hossein Nowroozzadeh
Mohammad Hossein Nowroozzadeh
ZTZahra Tajbakhsh
Zahra Tajbakhsh
MBMansoureh Bagheri
Mansoureh Bagheri
MGMaryam Ghoreyshi
Maryam Ghoreyshi
MRMohammad Reza Razeghinejad
Mohammad Reza Razeghinejad
Purpose: To assess the agreement between a swept-source optical biometry device (IOLMaster 700) and a Scheimpflug-based topography device (Pentacam HR) in measuring the corneal diameter. Methods: A total of 100 eyes from 100 cataract surgery candidates were enrolled. The white-to-white (WTW) distance measurements provided by both devices were recorded and analyzed. A paired t test was performed to compare the mean values of the WTW distance between the IOLMaster 700 and Pentacam HR. The Bland–Altman analysis was used to evaluate the agreement between the measurements of both devices. Results: Mean age (±SD) of the participants was 65.9 ± 3.3 years, and 58 (58%) were men. The mean WTW distances measured by the IOLMaster 700 and Pentacam HR were 11.72 ± 0.45 mm and 11.41 ± 0.42 mm, respectively (P < 0.001). The overall 95% limits of agreement were −0.17 and 0.78 mm. The 95% limits of agreement between the measurements of the 2 devices were −0.30 and 0.84 versus −0.07 and 0.72 for eyes with WTW distances of ≤11.50 mm versus >11.50 mm, respectively. Conclusions: According to the results of this study, the IOLMaster 700 may overestimate the WTW distance measurements by up to 0.78 mm compared with the Pentacam HR, so these 2 devices should not be used interchangeably for this purpose. The agreement is somehow weaker for eyes with WTW distances of 11.50 mm or less than those with WTW distances greater than 11.50 mm.

11 October 2012 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
PDF file
ZTZahra Tajbakhsh
Zahra Tajbakhsh
MYMasood Yasemi
Masood Yasemi
MNMohammad H Nowroozzadeh
Mohammad H Nowroozzadeh
MAMohammad Aghazadeh‐Amiri
Mohammad Aghazadeh‐Amiri
STSeyedmehdi Tabatabaee
Seyedmehdi Tabatabaee
MZMohammad Zamani
Mohammad Zamani

6 February 2023 in Eye
Verified
Journal Article
Open access
PDF file
ZTZahra Tajbakhsh
Zahra Tajbakhsh
BGBlanka Golebiowski
Blanka Golebiowski
Fiona StapletonFiona Stapleton
Fiona Stapleton
AAAli Alghamdi
Ali Alghamdi
PGPaul E. Gray
Paul E. Gray
Isabelle JalbertIsabelle Jalbert
Isabelle Jalbert
Background: Corneal and conjunctival epithelial dendritic cells (DC) have an established role in vernal keratoconjunctivitis, however, their role in more prevalent forms of allergic eye disease remains unclear. This study evaluated corneal and conjunctival epithelial DC density, morphology, and distribution observed using in vivo confocal microscopy (IVCM) in allergic conjunctivitis. Methods: In this prospective, observational study, 66 participants (mean age 36.6 ± 12.0 years, 56% female): 33 with allergic conjunctivitis and 33 controls were recruited. IVCM was performed at the corneal centre, inferior whorl, corneal periphery, corneal limbus, and temporal bulbar conjunctiva. DC were counted and their morphology was assessed as follows: largest cell body size, presence of dendrites, and presence of long and thick dendrites. Mixed model analysis (DC density) and non-parametric tests (DC morphology) were used. Results: DC density was higher in allergic participants at all locations (p ≤ 0.01), (corneal centre median (IQR) 21.9 (8.7–50.9) cells/mm2 vs 13.1 (2.8–22.8) cells/mm2; periphery 37.5 (15.6-67.2) cells/mm2 vs 20 (9.4–32.5) cells/mm2; limbus 75 (60-120) cells/mm2 vs 58.1 (44.4–66.2) cells/mm2; conjunctiva 10 (0–54.4) cells/mm2 vs 0.6 (0–5.6) cells/mm2, but not at the inferior whorl 21.9 (6.2–34.4) cells/mm2 vs 12.5 (1.9–37.5) cells/mm2, p = 0.20. At the corneal centre, allergic participants had larger DC bodies (p = 0.02), a higher proportion of DC with dendrites (p = 0.02) and long dendrites (p = 0.003) compared to controls. Conclusions: Corneal and conjunctival DC density was increased, and morphology altered in allergic conjunctivitis. These findings imply that the ocular surface immune response was upregulated and support an increased antigen-capture capacity of DC in allergic conjunctivitis.

17 October 2022 in Acta Ophthalmologica
Verified
Journal Article
Open access
CCCecilia Chao
Cecilia Chao
ZTZahra Tajbakhsh
Zahra Tajbakhsh
FSFiona Stapleton
Fiona Stapleton
RMRabia Mobeen
Rabia Mobeen
MMMichele C. Madigan
Michele C. Madigan
BGBlanka Golebiowski
Blanka Golebiowski
Purpose LASIK causes corneal nerve damage and may affect the neuro-immune crosstalk. This study examined the effects of LASIK on corneal epithelial dendritic cells (CEDC) density and morphology and explored their relationships with corneal nerves and tear neuropeptides. A grading system was developed to assess CEDC morphology. Methods Intra- and inter-observer repeatability of the CEDC morphology grading system was established using kappa (kappa). In vivo confocal microscope images of the central cornea were captured from 20 participants who had undergone LASIK 12-16 months earlier and 20 controls (age 18-32 years, 55%F). CEDC density was counted manually, and CEDC morphology was assessed using a new grading system. CEDC sub-types (contacting nerves [CEDCc] and not contacting nerves [CEDCnc]) were also assessed. Differences in CEDC density and morphology were examined using mixed models and chi-squared test. Relationships between CEDC and corneal nerve parameters and tear substance P were explored using Spearman's correlation. Results Excellent intra- and inter-observer repeatability was demonstrated for the grading system (kappa = 0.82-0.97). In post-LASIK participants, CEDC density was lower compared with controls (5 [0-34] vs. 21 [7-77] cells/mm(2); p = 0.01), and the proportion of CEDC with thick dendrites was higher (55%-73% vs. 11%-21%, p < 0.003). Higher tear substance P levels were associated with higher CEDC density (rho = 0.48, p = 0.003). Fewer nerve interconnections were observed in participants in whom CEDC had dendrites (p = 0.03). CEDC sub-types followed a similar pattern to CEDC. Conclusions The findings suggest that CEDC may remain altered more than 12 months post-LASIK. The association with substance P suggests a role for CEDC in corneal neurogenic inflammation.

8 April 2022 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
RSRamin Salouti
Ramin Salouti
MNM. Hossein Nowroozzadeh
M. Hossein Nowroozzadeh
AAAli Azizi
Ali Azizi
KSKia Bd Salouti
Kia Bd Salouti
MGMaryam Ghoreyshi
Maryam Ghoreyshi
ZTZahra Tajbakhsh
Zahra Tajbakhsh
Purpose: To assess the associations of angle κ and Pentacam decentration indices with elevation maps in normal refractive surgery candidates. Setting: Salouti Cornea Research Center, Salouti Eye Clinic, Shiraz, Iran. Design: Retrospective observational study. Methods: In this research, the right eyes of 173 refractive surgery candidates were assessed. Data of front and back corneal elevation maps, keratometric data, decentration indices, and corneal astigmatism obtained by Pentacam HR system and angle κ obtained by Orbscan IIz were extracted. Maximum elevation (or depression) for each of the 4 quadrants was recorded. Correlations of elevation values with angle κ, Pentacam decentration indices, keratometry, and astigmatism were examined by Pearson correlation coefficient. 148 age- and sex-matched cases with keratoconus grade 1 were selected as a positive control group, and Pentacam variables were compared between the groups. Results: Overall, data from 173 eyes of 173 normal refractive surgery candidates and 148 eyes of 148 patients with keratoconus were recorded and analyzed. In normal refractive surgery candidates, the mean of angle κ was 5.32 ± 1.36 (SD) degrees. Angle κ had a positive correlation with front and back temporal elevations based on a best-fit sphere (BFS) (r = 0.339, P = .001; r = 0.300, P < .001, respectively). Front and back keratometric astigmatisms were positively correlated with front and back nasal and temporal elevations (r ≥ 0.543, P < .001) and negatively correlated with superior and inferior elevations (r ≤ −0.547, P < .001). These associations no longer existed when using best-fit toric ellipse (BFTE) for calculating elevation data. The thinnest point to vertex decentration was significantly associated with the back temporal elevation (based on the BFTE) in both normal (r = 0.311, P < .001) and keratoconus (r = 0.190, P = .021) eyes. Conclusions: This study showed that elevation maps obtained by the Pentacam system using BFS might be affected by both the large angle κ and corneal astigmatism, confounding the preoperative assessment of refractive surgery candidates. Using BFTE as a reference for calculating elevation data should eliminate most diagnostic issues and thus is encouraged in this context.

19 May 2017 in Seminars in Ophthalmology
Verified
Journal Article
Closed access
RRReza Razeghinejad
Reza Razeghinejad
ZTZahra Tajbakhsh
Zahra Tajbakhsh
MNM. Hossein Nowroozzadeh
M. Hossein Nowroozzadeh
SHShane J. Havens
Shane J. Havens
DGDeepta Ghate
Deepta Ghate
VGVikas Gulati
Vikas Gulati
Purpose: The Water-Drinking Test (WDT) has been shown to predict the diurnal IOP change. This study evaluates the factors that may affect the WDT results. Methods: This study was conducted on 203 glaucoma patients who had undergone trabeculectomy (53) or tube surgery (31), or had a medically controlled open-angle (82) or closed-angle (37) glaucoma. IOP was measured at baseline and then every 15 minutes over a one-hour period after drinking water. The main outcome measures were IOP change (increase in IOP from baseline) at all measurement time points, IOP peak (highest IOP after drinking water), IOP fluctuation (difference between IOP peak and baseline), and assessing the association of these IOPs with a patient’s demographic and management modalities. Results: The mean age of the participants was 54±18 years, and 113 (56%) were male. Female patients showed greater IOP fluctuation than males (7.28 vs. 5.92 mm Hg; P=0.016), and a greater IOP peak (22.7 vs. 20.1 mm Hg; P=0.001). The observed associations between gender and IOP changes were only significant in <50 years. IOP at 60 minutes was greater in tube than trabeculectomy (5.6 vs. 3.1 mm Hg; P=0.007). The number of topical medications showed a direct independent association with IOP changes (P<0.001). Compared to other classes of topical medications, latanoprost showed lower WDT-IOP profile (P=0.0003). Conclusions: WDT-IOP change was diminished in subjects on latanoprost, and was greater in females <50 years, and those on greater number of medications.