Background: Odour-baited traps are useful for vector surveillance and control. However, most existing traps have shown inconsistent recapture rates across different mosquito species, necessitating the need for more effective and efficient traps. The MTego trap with integrated thermal stimuli has been developed as an alternative trap. This study was undertaken to determine and compare the efficacy of the MTego trap to that of the Biogents (BG) modular BG-Pro (BGP) trap for sampling different mosquito species in a semi-field system. Methods: Fully balanced Latin square design experiments (no-choice and dual choice) were conducted in semi-field chambers using laboratory-reared female Anopheles gambiae sensu stricto, Anopheles funestus, Anopheles arabiensis, Culex quinquefasciatus and Aedes aegypti. There were 16 replicates, and 50 mosquitoes of each species were released in each chamber per replicate. The evaluated traps were as follows: the MTego trap baited with PM6 (MT-PM6), the MTego trap baited with BG-Lure (BGL) (MT-BGL), and the BGP trap baited with BG-Lure (BGP-BGL). Results: In the no-choice test, the MT-BGL and BGP-BGL traps captured a similar proportion of An. gambiae (31% vs 29%, P-value = 0.519) and An. funestus (32% vs 33%, P = 0.520). The MT-PM6 and BGP-BGL traps showed no significant difference in capturing Ae. aegypti (33% vs 31%, P = 0.324). However, the BGP-BGL caught more An. arabiensis and Cx. quinquefasciatus mosquitoes than the other traps (P < 0.0001). In the dual-choice test of MT-PM6 vs BGP-BGL, similar proportions of An. funestus (25% vs 27%, P = 0.473) and Ae. aegypti (29% vs 25%, P = 0.264) were captured in the traps, while the BGP-BGL captured more An. gambiae, An. arabiensis and Cx. quinquefasciatus mosquitoes than the MT-PM6 (P < 0.0001). Conclusions: This study demonstrated that the MTego trap has potential as a tool that can be used interchangeably with the BGP trap for sampling anthropophilic mosquitoes including African malaria vectors An. gambiae and An. funestus and the principal arbovirus vector Ae. aegypti. Graphical
In Tanzania, dengue outbreaks have occurred almost annually over the past decade, with each new outbreak becoming more severe. This study investigated the prevalence of dengue virus (DENV) serotypes in the wild Aedes aegypti and their blood sources to determine human exposure risk in Dar es Salaam, Tanzania. A two-year longitudinal survey was conducted in the Ilala, Kinondoni, and Temeke districts of Dar es Salaam to sample Ae. aegypti mosquitoes using Biogents Sentinel trap (BGS), Prokopack aspiration, and Gravid Aedes trap (GAT). Collected mosquitoes were pooled in groups of 10 and tested for DENV1–4 serotypes using reverse transcription polymerase chain reaction (RT-qPCR). Blood meal sources were identified using an enzyme-linked immunosorbent assay (ELISA). Of 854 tested pools, only DENV-2 was detected and was found in all three districts: Temeke (3/371 pools), Ilala (1/206 pools), and Kinondoni (1/277 pools). Blood meal analysis showed a strong preference for humans (81%) as well as for mixed blood meals that contained human blood and other hosts (17%). Out of 354 collected hosts seeking Ae. aegypti, 78.5% were captured outdoors and 21.5% indoors. This study confirms the circulation of DENV-2 in Ae. aegypti populations, indicating a potential dengue outbreak risk in Tanzania. This study also demonstrates that xenomonitoring may be feasible in this setting. The mosquitoes’ strong preference for human hosts and predominance in outdoor settings pose challenges for dengue control efforts.
The study assessed the trapping efficacy of locally modified (1) Gravid Aedes Trap (GAT) lined with insecticide-treated net (ITN) as a killing agent and (2) Autocidal Gravid Ovitrap (AGO) with sticky board in the semi-field system (SFS) and field setting. Fully balanced Latin square experiments were conducted to compare GAT lined with ITN vs. AGO, both with either yeast or grass infusion. Biogent-Sentinel (BGS) with BG-Lure and no CO2 was used as a standard trap for Aedes mosquitoes. In the SFS, GAT outperformed AGO in collecting both nulliparous (65% vs. 49%, OR = 2.22, [95% CI: 1.89–2.60], p < 0.001) and gravid mosquitoes (73% vs. 64%, OR = 1.67, [95% CI: 1.41–1.97], p < 0.001). Similar differences were observed in the field. Yeast and grass infusion did not significantly differ in trapping gravid mosquitoes (OR = 0.91, [95% CI: 0.77–1.07], p = 0.250). The use of ITN improved mosquito recapture from 11% to 70% in the SFS. The same trend was observed in the field. Yeast was chosen for further evaluation in the optimized GAT due to its convenience and bifenthrin net for its resistance management properties. Mosquito density was collected when using 4× GATs relative to BGS-captured gravid mosquitoes 64 vs. 58 (IRR = 0.82, [95% CI: 0.35–1.95], p = 0.658) and showed no density dependence. Deployment of multiple yeast-baited GAT lined with bifenthrin net is cost-effective (single GAT < $8) compared to other traps such as BGS ($160).
Introduction: The resistance of malaria vectors to pyrethroids has compromised the efficacy of pyrethroid insecticide-treated nets (ITNs). In response, ITNs with pyrethroids and piperonyl butoxide (PBO) synergists were developed to overcome metabolic pyrethroid resistance mechanisms. One such net is Vector Guard®. To demonstrate its potential efficacy for public health use, a comparative efficacy study was conducted to evaluate Vector Guard® relative to Olyset® Plus (a pyrethroid–PBO ITN proven to reduce malaria transmission more effectively than pyrethroid ITNs) and Royal® Sentry 2.0 (a pyrethroid-only ITN included to demonstrate the added benefit of PBO) in experimental huts in Tanzania.Methods: An experimental hut trial using two blocks of a 7 × 7 Latin square design was conducted over seven rounds (49 experimental nights). Treatments were rotated at the end of each round, and volunteers were rotated nightly within one block. Both unwashed and 20× washed nets of each type were evaluated, alongside an untreated net used as a negative control. The primary endpoint was the proportion of Anopheles arabiensis that died within 24 h, and the secondary endpoint was the proportion of blood feeding. Data were analyzed using binomial logistic regression with fixed effects using a 7% non-inferiority margin.Results: The pooled results showed that Vector Guard® was non-inferior and was superior to Olyset® Plus, with higher mortality for Vector Guard® [28% vs. 18%; odds ratio (OR) = 1.93, 95%CI = 1.81–2.06]. Both pyrethroid–PBO nets were superior to Royal Sentry® 2.0 (p < 0.001) in terms of mosquito mortality. For the secondary blood feeding endpoint, Vector Guard® was also found to be non-inferior to Olyset® Plus (0.6% vs. 0.2%; OR = 2.37, 95%CI = 1.77–3.17). Vector Guard® showed similar efficacy to Royal Sentry® 2.0 in reducing the proportion of mosquito blood feeding (0.6% vs. 0.6%; OR = 0.85, 95%CI = 0.68–1.07, p = 0.161).Conclusion: Vector Guard® demonstrated superior mosquito mortality compared with both Olyset® Plus and Royal Sentry® 2.0, indicating that Vector Guard® is another promising pyrethroid–PBO ITN for the control of resistant malaria vectors. The addition of Vector Guard® to the class of pyrethroid–PBO ITNs will enable malaria control programs to select cost-effective ITNs, improving access to effective protection from malaria transmitted by resistant vectors.
In Tanzania, dengue outbreaks have occurred almost annually over the past decade, with each new outbreak becoming more severe. This study investigated the prevalence of dengue virus (DENV) serotypes in the wild Aedes aegypti and their blood sources to determine human exposure risk in Dar es Salaam, Tanzania. A two-year longitudinal survey was conducted in Ilala, Kinondoni, and Temeke districts of Dar es Salaam to sample Ae. aegypti mosquitoes using Biogents Sentinel trap (BGS), Prokopack aspiration and Gravid Aedes trap (GAT). Collected mosquitoes were pooled in groups of 10 and tested for DENV1-4 serotypes using reverse transcription polymerase chain reaction (RT-qPCR). Blood meal sources were identified using an enzyme-linked immunosorbent assay (ELISA). Of 854 tested pools, only DENV-2 serotype was detected in all districts (Temeke (3/371 pools), Ilala (1/206 pools) and Kinondoni (1/277-pools)). Blood meal analysis showed a strong preference for humans (81%) and mixed blood meals (17%). Out of 354 collected host seeking Ae. aegypypti, 78.5% were captured outdoors and 21.5% indoors. This study confirms the circulation of DENV-2 in Ae. aegypti populations, indicating a potential dengue outbreak risk in Tanzania. The mosquitoes’ strong preference for human hosts and predominance in outdoor settings pose challenges for dengue control efforts.
The study assessed the trapping efficacy of locally-modified 1) Gravid Aedes Trap(GAT) lined with insecticide-treated net (ITN) as a killing agent, 2) Autocidal Gravid Ovitrap(AGO) with sticky board in the semi-field system (SFS) and field setting. Fully-balanced Latin square experiments were conducted to compare GAT lined with ITN vs AGO, both with either yeast or grass infusion. Biogents-Sentinel (BGS) with BG-Lure and no CO2 was used as standard trap for Aedes mosquitoes. In the SFS, GAT outperformed AGO in collecting both nulliparous (65% vs 49%,OR=2.22,[95%CI:1.89-2.60],p