Timothy F. F Witham

Dr. Timothy F. F Witham


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Neurosurgery
Verified
Journal Article
Closed access
PDF file
SPScott L. Parker
Scott L. Parker
MMMatthew J. McGirt
Matthew J. McGirt
SFS Harrison. Farber
S Harrison. Farber
AAAnubhav G. Amin
Anubhav G. Amin
ARAnne-Marie. Rick
Anne-Marie. Rick
TWTimothy F. F Witham
Timothy F. F Witham
BACKGROUND:. Pedicle screws are used to stabilize all 3 columns of the spine, but can be technically demanding to place. Although intraoperative fluoros

1 January 2014 in World Journal of Orthopedics
Verified
Journal Article
Open access
VPVarun Puvanesarajah
Varun Puvanesarajah
JLJason A Liauw
Jason A Liauw
SLSheng-Fu Lo
Sheng-Fu Lo
ILIoan A Lina
Ioan A Lina
TWTimothy F. F Witham
Timothy F. F Witham
Techniques and accuracy of thoracolumbar pedicle screw placement

1 June 2014 in Neurosurgery
Verified
Journal Article
Closed access
PDF file
MBMohamad Bydon
Mohamad Bydon
MMMohamed Macki
Mohamed Macki
PKPaul Kaloostian
Paul Kaloostian
DSDaniel M. Sciubba
Daniel M. Sciubba
JWJean-Paul Wolinsky
Jean-Paul Wolinsky
TWTimothy F. F Witham
Timothy F. F Witham
BACKGROUND:. C5 palsy is a known cause of postoperative deltoid weakness. Prognostic variables affecting the incidence of the palsy have been poorly und

1 March 2022 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
PDF file
ALAnn Liu
Ann Liu
YJYike Jin
Yike Jin
ECEthan Cottrill
Ethan Cottrill
MKMajid Khan
Majid Khan
EWErick Westbroek
Erick Westbroek
TWTimothy F. F Witham
Timothy F. F Witham
OBJECTIVE: Augmented reality (AR) is a novel technology which, when applied to spine surgery, offers the potential for efficient, safe, and accurate placement of spinal instrumentation. The authors report the accuracy of the first 205 pedicle screws consecutively placed at their institution by using AR assistance with a unique head-mounted display (HMD) navigation system. METHODS: A retrospective review was performed of the first 28 consecutive patients who underwent AR-assisted pedicle screw placement in the thoracic, lumbar, and/or sacral spine at the authors’ institution. Clinical accuracy for each pedicle screw was graded using the Gertzbein-Robbins scale by an independent neuroradiologist working in a blinded fashion. RESULTS: Twenty-eight consecutive patients underwent thoracic, lumbar, or sacral pedicle screw placement with AR assistance. The median age at the time of surgery was 62.5 (IQR 13.8) years and the median body mass index was 31 (IQR 8.6) kg/m2. Indications for surgery included degenerative disease (n = 12, 43%); deformity correction (n = 12, 43%); tumor (n = 3, 11%); and trauma (n = 1, 4%). The majority of patients (n = 26, 93%) presented with low-back pain, 19 (68%) patients presented with radicular leg pain, and 10 (36%) patients had documented lower extremity weakness. A total of 205 screws were consecutively placed, with 112 (55%) placed in the lumbar spine, 67 (33%) in the thoracic spine, and 26 (13%) at S1. Screw placement accuracy was 98.5% for thoracic screws, 97.8% for lumbar/S1 screws, and 98.0% overall. CONCLUSIONS: AR depicted through a unique HMD is a novel and clinically accurate technology for the navigated insertion of pedicle screws. The authors describe the first 205 AR-assisted thoracic, lumbar, and sacral pedicle screws consecutively placed at their institution with an accuracy of 98.0% as determined by a Gertzbein-Robbins grade of A or B.

28 October 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
ARAlexandra N. Rindone
Alexandra N. Rindone
XLXIAONAN LIU
XIAONAN LIU
SFStephanie Farhat
Stephanie Farhat
APAlexander Perdomo-Pantoja
Alexander Perdomo-Pantoja
TWTimothy F. F Witham
Timothy F. F Witham
WGWarren L. Grayson
Warren L. Grayson
Vascularization is critical for skull development, maintenance, and healing. Yet, there remains a significant knowledge gap in the relationship of blood vessels to cranial skeletal progenitors during these processes. Here, we introduce a quantitative 3D imaging platform to enable the visualization and analysis of high-resolution data sets (>100 GB) throughout the entire murine calvarium. Using this technique, we provide single-cell resolution 3D maps of vessel phenotypes and skeletal progenitors in the frontoparietal cranial bones. Through these high-resolution data sets, we demonstrate that CD31hiEmcnhi vessels are spatially correlated with both Osterix+ and Gli1+ skeletal progenitors during postnatal growth, healing, and stimulated remodeling, and are concentrated at transcortical canals and osteogenic fronts. Interestingly, we find that this relationship is weakened in mice with a conditional knockout of PDGF-BB in TRAP+ osteoclasts, suggesting a potential role for osteoclasts in maintaining the native cranial microvascular environment. Our findings provide a foundational framework for understanding how blood vessels and skeletal progenitors spatially interact in cranial bone, and will enable more targeted studies into the mechanisms of skull disease pathologies and treatments. Additionally, our technique can be readily adapted to study numerous cell types and investigate other elusive phenomena in cranial bone biology.

15 April 2014 in Spine
Verified
Journal Article
Closed access
SPScott L. Parker
Scott L. Parker
AAAnubhav G. Bs Amin
Anubhav G. Bs Amin
DSDavid Bs Santiago-Dieppa
David Bs Santiago-Dieppa
JLJason A. Liauw
Jason A. Liauw
ABAli Bydon
Ali Bydon
TWTimothy F. F Witham
Timothy F. F Witham
Study Design. Retrospective case series. Objective. Evaluate the incidence and clinical significance of vascular encroachment resulting from freehand placement of pedicle screws in the thoracic and lumbosacral spine. Summary of Background Data. Pedicle screws are routinely used to effectively stabilize all 3 columns of the spine but can be technically demanding to place in the setting of variable anatomy. There is a paucity of data regarding iatrogenic major vascular injuries during posterior instrumentation procedures. Methods. We retrospectively reviewed the records of all patients undergoing freehand pedicle screw placement without image guidance in the thoracic or lumbar spine during a 7-year period. The incidence and extent of vascular encroachment by a pedicle screw was determined by review of routine postoperative computed tomographic scans obtained within 24 hours of all surgical procedures. Vascular encroachment was defined as a pedicle screw that was touching or deforming the wall of a major vessel. Results. A total of 964 patients received 6816 freehand-placed pedicle screws in the thoracolumbar spine. Fifteen (0.22%) screws that encroached a major vascular structure were identified. Ten (0.29%) thoracic pedicle screws encroached on the aorta, 4 (0.14%) lumbar screws on the common iliac vein, and 1 S1 screw (0.19%) on the internal iliac vein. In consultation with vascular surgery, it was determined whether revision surgery and the technique/approach for the revision procedure should be recommended. Two (0.21%) patients required revision surgery to remove the encroaching pedicle screw (T5 and T8) due to concern for vascular injury. Both patients were asymptomatic and recovered without further complications after revision surgery. Conclusion. Vascular encroachment of major vessels occurs rarely in the setting of freehand pedicle screw placement in the thoracolumbar spine. Although rare, delayed vascular injury from errant pedicle screw placement has been reported in the literature. The aorta seems to be the vessel at the highest risk of injury. Routine intraoperative or postoperative computed tomographic scanning allows for early identification of pedicle screws encroaching on vascular structures thereby facilitating early revision surgery. Level of Evidence: 4