Donguk Park

Prof. Donguk Park

Dept. of Environ. Health, Korea National Open University, 169, Dongsungdong, Jongroku, Seoul 110-791, Korea
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
DPDonguk Park
Donguk Park
JYJeong-Kwan Yeom
Jeong-Kwan Yeom
WLWon Jae Lee
Won Jae Lee
KLKyeong-Min Lee
Kyeong-Min Lee
Aims: We assessed the levels of airborne bacteria, Gram-negative bacteria (GNB), and fungi in six hospital lobbies, and investigated the environmental and hospital characteristics that affected the airborne microorganism levels. Methods: An Andersen single-stage sampler equipped with appropriate nutrition plate agar was used to collect the samples. The three types of microorganisms were repeatedly collected at a fixed location in each hospital (assumed to be representative of the entire hospital lobby) from 08:00 through 24:00, with a sampling time of less than 5 min. Temperature and relative humidity were simultaneously monitored. Results: Multiple regression analysis was used to identify the major factors affecting microorganism levels. The average levels of bacteria (7.2 × 102 CFU/m3), GNB (1.7 × 10 CFU/m3), and fungi (7.7 × 10 CFU/m3) indicated that all hospital lobbies were generally contaminated. Season was the only factor that significantly affected the levels of all microorganisms (p < 0.0001), where contamination was the highest during the summer, significantly higher than during the winter. Other significant factors varied by microorganism, as follows: airborne bacteria (number of people in the lobby, sampling time), GNB (scale of hospital), and fungi (humidity and air temperature). Conclusions: Hospital lobby air was generally contaminated with microorganisms, including bacteria, GNB, and fungi. Environmental factors that may significantly influence the airborne concentrations of these agents should be managed to minimize airborne levels.

1 October 2017 in Science of The Total Environment
Verified
Journal Article
Closed access
DPDonguk Park
Donguk Park
SRSeung-Hun Ryu
Seung-Hun Ryu
HLHeung-Kyu Lim
Heung-Kyu Lim
SKSun-Kyung Kim
Sun-Kyung Kim
YCYe-Yong Choi
Ye-Yong Choi
SHSoo-Jong Hong
Soo-Jong Hong

31 December 2014 in Indoor Air
Verified
Journal Article
Closed access
PDF file
DPDonguk Park
Donguk Park
MFM C Friesen
M C Friesen
HRH S Roh
H S Roh
YCY Y Choi
Y Y Choi
JAJ J Ahn
J J Ahn
DPD M Paek
D M Paek
We conducted a comprehensive humidifier disinfectant exposure characterization for 374 subjects with lung disease who presumed their disease was related to humidifier disinfectant use (patient group) and for 303 of their family members (family group) for an ongoing epidemiological study. We visited the homes of the registered patients to investigate disinfectant use characteristics. Probability of exposure to disinfectants was determined from the questionnaire and supporting evidence from photographs demonstrating the use of humidifier disinfectant, disinfectant purchase receipts, any residual disinfectant, and the consistency of their statements. Exposure duration was estimated as cumulative disinfectant use hours from the questionnaire. Airborne disinfectant exposure intensity (μg/m3) was estimated based on the disinfectant volume (ml) and frequency added to the humidifier per day, disinfectant bulk level (μg/ml), the volume of the room (m3) with humidifier disinfectant, and the degree of ventilation. Overall, the distribution patterns of the intensity, duration, and cumulative exposure to humidifier disinfectants for the patient group were higher than those of the family group, especially for pregnant women and patients ≤6 years old. Further study is underway to evaluate the association between the disinfectant exposures estimated here with clinically diagnosed lung disease.

6 July 2019 in Indoor Air
Verified
Journal Article
Closed access
PDF file
SRSeung‐Hun Ryu
Seung‐Hun Ryu
DPDonguk Park
Donguk Park
ELEun Lee
Eun Lee
SPSoyoung Park
Soyoung Park
SLSo‐Yeon Lee
So‐Yeon Lee
SHSoo‐Jong Hong
Soo‐Jong Hong

2 September 2014 in Environmental Health
Verified
Journal Article
Open access
PDF file
DPDonguk Park
Donguk Park
JLJong-Han Leem
Jong-Han Leem
KLKyoungmu Lee
Kyoungmu Lee
HLHeungkyu Lim
Heungkyu Lim
YCYeyong Choi
Yeyong Choi
DPDomyung Paek
Domyung Paek
This study describes 17 families with 38 lung injury patients (14 males, 24 females; 22 preschool-age children less than six years of age and 16 individuals of 13–50 years) who used disinfectant added to humidifiers in the home. Clinical examination and humidifier disinfectant-use histories were taken, and a thorough home investigation was performed to assess exposure to humidifier disinfectant. Nine of the patients (three pregnant females, six preschool-age children) died soon after they first developed lung damage. Six (16%) were pregnant females and 22 (58%) were preschool-aged children younger than six years. The patients used humidifier disinfectant products containing either polyhexamethylene guanidine phosphate (PHMG, n = 36) or oligo(2-(2-ethoxy)ethoxyethyl guanidinium chloride (PGH, n = 2). Twenty-six patients (68%) used the brand "Oxy"®, which contains PHMG. Of the ten patients with fatal lung injury, nine were found to have used PHMG. Our findings suggest that the use of humidifier disinfectant products containing either PGH or PHMG can cause lung injury, especially in preschool-age children younger than six years and pregnant women.

24 August 2015 in Annals of Occupational and Environmental Medicine
Verified
Journal Article
Open access
PDF file
HSHee-Seung Son
Hee-Seung Son
SKSoo Geun Kim
Soo Geun Kim
BSByung-Seong Suh
Byung-Seong Suh
DPDonguk Park
Donguk Park
DKDae-Seon Kim
Dae-Seon Kim
JSJoon Sakong
Joon Sakong
Son HS, et al. Ann Occup Environ Med. 2015 Aug;27(1):20. https://doi.org/10.1186/s40557-015-0071-2