Jianwei Wu

Prof. Jianwei Wu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

20 May 2024 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
SDShiyuan Dong
Shiyuan Dong
ZLZihan Liu
Zihan Liu
YLYuyang Lou
Yuyang Lou
DLDong Luo
Dong Luo
JWJianwei Wu
Jianwei Wu
YDYuming Dong
Yuming Dong
This paper develops a high-precision miniature three-dimensional Fiber Bragg Grating (FBG) force sensor designed for detecting and locating hard masses within tissues during Minimally Invasive Surgery (MIS) and robotic-assisted MIS palpation processes. The prototype consists of three FBG-etched optical fibers and an integrated elastomer. The fibers are suspended and parallel to each other within the elastomer, allowing each FBG to be directly compressed or stretched under stress. A novel model, combining segment-by-segment sensitivity and differential decoupling, is adopted for decoupling three-dimensional forces. This approach significantly reduces the crosstalk error caused by spatial forces, avoids the complexity of assembling multiple fibers in previous designs, and reduces the sensor's size, facilitating its integration into MIS procedures. Calibration experiments are conducted to determine the sensor's force sensitivity coefficients, achieving resolutions of 4.35 mN, 3.99 mN, and 3.30 mN in the X, Y, and Z directions, respectively. Through discrete and drag palpation tests on silicone with different types of hard inclusions, the results demonstrate that the proposed prototype has the ability to effectively identify the size, hardness, and depth of hard objects from the contact force information. Additionally, ex vivo porcine kidney palpation experiments are conducted to further verify the feasibility of locating hard masses during MIS palpation.

6 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YLYuyang Lou
Yuyang Lou
TYTianyu Yang
Tianyu Yang
DLDong Luo
Dong Luo
JWJianwei Wu
Jianwei Wu
YDYuming Dong
Yuming Dong
Objective: To accurately achieve distal contact force, a novel temperature-compensated sensor is developed and integrated into an atrial fibrillation (AF) ablation catheter. Methods: A dual elastomer-based dual FBGs structure is used to differentiate the strain on the two FBGs to achieve temperature compensation, and the design is optimized and validated by finite element simulation. Results: The designed sensor has a sensitivity of 90.5 pm/N, resolution of 0.01 N, and root–mean–square error (RMSE) of 0.02 N and 0.04 N for dynamic force loading and temperature compensation, respectively, and can stably measure distal contact forces with temperature disturbances. Conclusion: Due to the advantages, i.e., simple structure, easy assembly, low cost, and good robustness, the proposed sensor is suitable for industrial mass production.

27 October 2018 in Indian Journal of Physics
Verified
Journal Article
Closed access
PDF file
ZLZheng Li
Zheng Li
ZGZhou Ge
Zhou Ge
XZXue-Yan Zhang
Xue-Yan Zhang
ZHZheng-Yue Hu
Zheng-Yue Hu
DZDan Zhao
Dan Zhao
JWJianwei Wu
Jianwei Wu

28 May 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SDShiyuan Dong
Shiyuan Dong
TYTianyu Yang
Tianyu Yang
YLYuyang Lou
Yuyang Lou
DLDong Luo
Dong Luo
BYBin Yang
Bin Yang
YDYuming Dong
Yuming Dong
Accurate measurement of contact forces between medical instrument tips and tissues is a critical challenge in minimally invasive surgery (MIS), where the lack of tactile feedback can compromise surgical precision and safety. To address this, this article presents a novel miniature high-resolution 3-D force sensor based on fiber Bragg grating (FBG) technology. Compared to traditional methods that use multiple optical fibers and complex structures to decouple forces, this sensor employs a cantilever beam structure for biaxial lateral force sensing, while a hollow cylindrical structure is utilized for axial force sensing. This unique combination allows for the independent adjustment of sensitivity in each segment. Finite-element analysis is used to optimize the structure to approximate isotropy. Experiments demonstrate that the sensor achieves an axial force Z resolution of 3.36 mN and a dynamic measurement error of 2.97% within a range of 0–2 N. Meanwhile, lateral force resolutions for X- and Y-directions within a range of −0.5 to 0.5 N are 4.37 and 3.95 mN, respectively, with dynamic measurement errors of 3.79% and 5.12%. Additionally, porcine kidneys are adopted for ex vivo experiments to simulate tumors, validating the feasibility of the designed FBG force sensor in MIS palpation. The simulated vessel identification experiment further validated the ability to detect vessels at different depths within organs, highlighting the potential of the designed sensor for applications in MIS.

7 February 2022 in Optics Express
Verified
Journal Article
Closed access
WLWei Liu
Wei Liu
TYTianyu Yang
Tianyu Yang
YSYunjie Shi
Yunjie Shi
JWJianwei Wu
Jianwei Wu
YDYuming Dong
Yuming Dong
In this paper, the Karhunen-Loeve transform (KLT) and wavelength domain interferometric spectral singular value decomposition (SVD) are used for the first time to demodulate the pressure of an optical fiber Fabry-Perot (F-P) micro-pressure sensor, and the feasibility of the proposed method is demonstrated experimentally. The eigenvalue decomposition of the dominant frequency part of the beam-domain interferometric spectrum after the fast Fourier transform (FFT) is performed using KLT, and the singular value decomposition of the wavelength domain interferometric spectrum is additionally performed using SVD. Both methods use high-order eigenvalues as a new metric and then derive the relation between the new metric and the reference pressure. The two demodulation methods are experimentally compared, and we used an optical fiber F-P pressure sensor with unknown structure and material for pressure measurements. Even though the interferometric spectral signal is acquired using a coarse spectrometer (2.5 nm wavelength resolution), one can still achieve high demodulation accuracy with both algorithms. However, the SVD demodulation accuracy decreases significantly after reducing the spectral data points in the wavelength domain from 1566 to 783. KLT still has high demodulation accuracy and linearity after spectral data points are reduced from 1024 to 256 in the wavenumber domain. The satisfactory linearity of the measured pressure versus reference pressure and low reading errors validate the feasibility of the proposed demodulation algorithm.