Constant resistance energy (CRE) steel reinforcement has a yield strength of up to 750 MPa and an ultimate elongation of more than 20%. CRE reinforcement overcomes the contradiction between high yield strength and high uniform elongation of ordinary high-strength bars. This paper explores the flexural performance and load-carrying mechanisms of CRE-reinforced concrete beams through a series of experiments, while also presenting a theoretical analytical method for such specimens. Flexural tests on six CRE-reinforced concrete beams and two control tests on hot-rolled ribbed bar 400 (HRB400)-reinforced concrete beams were conducted in this paper. The study examines the influence of the shear–span ratio and reinforcement type on the mechanical response of the beams, including cracking load, yield load, and ultimate load, while analyzing the variation patterns of concrete strain and reinforcement strain. The experimental results demonstrate that as the shear–span ratio decreases, the crack resistance and load-carrying capacity of CRE-reinforced concrete beams improve. Under equivalent conditions, CRE-reinforced concrete beams exhibit higher load-carrying capacity compared to HRB-reinforced concrete beams, surpassing the latter by approximately 43% in terms of ultimate load. Additionally, this paper proposes a calculation method for the mechanical response of NPR-reinforced concrete beams and compares the theoretical values with the experimental values. The differences between the two are within 13%, which proves the reliability of the calculation method.
1 December 2022 in Journal of Composites for Construction
This study develops a new form of composite beam theory to study the connections of fiber reinforced polymers (FRPs), reinforced concrete beams, and closed-form solutions of four typical connections are derived and discussed. Comparisons with experimental data also show agreement. The maximum strain incompatibility of the mechanically anchored FRP system at two ends appears at the position where the first-order derivative of the applied bending moment is zero or at the boundary positions. Compared with strain incompatibility, the slip is more critical for determining the composite behavior of the FRP-reinforced structure. The first-order derivative function of the slip is strain incompatibility. It is demonstrated that the structural response of this FRP system can be improved theoretically by introducing additional mechanical anchors at the critical locations from the slip perspective.