Gokhan Ceylan

Dr. Gokhan Ceylan

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2023 in European Journal of Pediatrics
Verified
Journal Article
Closed access
PDF file
ESEkin Soydan
Ekin Soydan
MMMehmet Murat
Mehmet Murat
CKCeren Karahan
Ceren Karahan
AGAhmet Gonullu
Ahmet Gonullu
YAYigit Aksoy
Yigit Aksoy
HAHasan Agın
Hasan Agın

25 August 2022 in Frontiers in Medicine
Verified
Journal Article
Open access
ESEkin Soydan
Ekin Soydan
GCGokhan Ceylan
Gokhan Ceylan
STSevgi Topal
Sevgi Topal
PHPinar Hepduman
Pinar Hepduman
GAGulhan Atakul
Gulhan Atakul
HAHasan Agin
Hasan Agin
Introduction: We aimed to compare automated ventilation with closed–loop control of the fraction of inspired oxygen (FiO2) to automated ventilation with manual titrations of the FiO2 with respect to time spent in predefined pulse oximetry (SpO2) zones in pediatric critically ill patients.Methods: This was a randomized crossover clinical trial comparing Adaptive Support Ventilation (ASV) 1.1 with use of a closed–loop FiO2 system vs. ASV 1.1 with manual FiO2 titrations. The primary endpoint was the percentage of time spent in optimal SpO2 zones. Secondary endpoints included the percentage of time spent in acceptable, suboptimal and unacceptable SpO2 zones, and the total number of FiO2 changes per patient.Results: We included 30 children with a median age of 21 (11–48) months; 12 (40%) children had pediatric ARDS. The percentage of time spent in optimal SpO2 zones increased with use of the closed–loop FiO2 controller vs. manual oxygen control [96.1 (93.7–98.6) vs. 78.4 (51.3–94.8); P < 0.001]. The percentage of time spent in acceptable, suboptimal and unacceptable zones decreased. Findings were similar with the use of closed-loop FiO2 controller compared to manual titration in patients with ARDS [95.9 (81.6–98.8) vs. 78 (49.5–94.8) %; P = 0.027]. The total number of closed-loop FiO2 changes per patient was 52 (11.8–67), vs. the number of manual changes 1 (0–2), (P < 0.001).Conclusion: In this randomized crossover trial in pediatric critically ill patients under invasive ventilation with ASV, use of a closed–loop control of FiO2 titration increased the percentage of time spent within in optimal SpO2 zones, and increased the total number of FiO2 changes per patient.Clinical trial registration: ClinicalTrials.gov, identifier: NCT04568642.

16 November 2022 in Frontiers in Medicine
Verified
Journal Article
Open access
OSOzlem Sandal
Ozlem Sandal
GCGokhan Ceylan
Gokhan Ceylan
STSevgi Topal
Sevgi Topal
PHPinar Hepduman
Pinar Hepduman
MCMustafa Colak
Mustafa Colak
HAHasan Ağın
Hasan Ağın
Background: We assessed the effect of a closed–loop oxygen control system in pediatric patients receiving high–flow nasal oxygen therapy (HFNO).Methods: A multicentre, single–blinded, randomized, and cross–over study. Patients aged between 1 month and 18 years of age receiving HFNO for acute hypoxemic respiratory failure (AHRF) were randomly assigned to start with a 2–h period of closed–loop oxygen control or a 2–h period of manual oxygen titrations, after which the patient switched to the alternative therapy. The endpoints were the percentage of time spent in predefined SpO2ranges (primary), FiO2, SpO2/FiO2, and the number of manual adjustments.Findings: We included 23 patients, aged a median of 18 (3–26) months. Patients spent more time in a predefined optimal SpO2range when the closed–loop oxygen controller was activated compared to manual oxygen titrations [91⋅3% (IQR 78⋅4–95⋅1%) vs. 63⋅0% (IQR 44⋅4–70⋅7%)], mean difference [28⋅2% (95%–CI 20⋅6–37⋅8%);P< 0.001]. Median FiO2was lower [33⋅3% (IQR 26⋅6–44⋅6%) vs. 42⋅6% (IQR 33⋅6–49⋅9%);P= 0.07], but median SpO2/FiO2was higher [289 (IQR 207–348) vs. 194 (IQR 98–317);P= 0.023] with closed–loop oxygen control. The median number of manual adjustments was lower with closed–loop oxygen control [0⋅0 (IQR 0⋅0–0⋅0) vs. 0⋅5 (IQR 0⋅0–1⋅0);P< 0.001].Conclusion: Closed-loop oxygen control improves oxygenation therapy in pediatric patients receiving HFNO for AHRF and potentially leads to more efficient oxygen use. It reduces the number of manual adjustments, which may translate into decreased workloads of healthcare providers.Clinical trial registration: [www.ClinicalTrials.gov], identifier [NCT 05032365].

6 April 2022 in Journal of Medical Mycology
Verified
Journal Article
Closed access
İDİlker Devrim
İlker Devrim
STSevgi Topal
Sevgi Topal
GCGokhan Ceylan
Gokhan Ceylan
YOYeliz Oruç
Yeliz Oruç
GGGamze Gülfidan
Gamze Gülfidan
HAHasan Ağın
Hasan Ağın

10 September 2024 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
GAGulhan Atakul
Gulhan Atakul
GCGokhan Ceylan
Gokhan Ceylan
OSOzlem Sandal
Ozlem Sandal
ESEkin Soydan
Ekin Soydan
PHPinar Hepduman
Pinar Hepduman
\A\R\Ngulhan Atakul
\R\Ngulhan Atakul
Background: The aim of this study is the evaluation of a closed-loop oxygen control system in pediatric patients undergoing invasive mechanical ventilation (IMV).Methods: Cross-over, multicenter, randomized, single-blind clinical trial. Patients between the ages of 1 month and 18 years who were undergoing IMV therapy for acute hypoxemic respiratory failure (AHRF) were assigned at random to either begin with a 2-hour period of closed-loop oxygen control or manual oxygen titrations. By using closed-loop oxygen control, the patients' SpO2 levels were maintained within a predetermined target range by the automated adjustment of the FiO2. During the manual oxygen titration phase of the trial, healthcare professionals at the bedside made manual changes to the FiO2, while maintaining the same target range for SpO2. Following either period, the patient transitioned to the alternative therapy. The outcomes were the percentage of time spent in predefined SpO2 ranges ±2% (primary), FiO2, total oxygen use, and the number of manual adjustments.Findings: The median age of included 33 patients was 17 (13–55.5) months. In contrast to manual oxygen titrations, patients spent a greater proportion of time within a predefined optimal SpO2 range when the closed-loop oxygen controller was enabled (95.7% [IQR 92.1–100%] vs. 65.6% [IQR 41.6–82.5%]), mean difference 33.4% [95%–CI 24.5–42%]; P < 0.001). Median FiO2 was lower (32.1% [IQR 23.9–54.1%] vs. 40.6% [IQR 31.1–62.8%]; P < 0.001) similar to total oxygen use (19.8 L/h [IQR 4.6–64.8] vs. 39.4 L/h [IQR 16.8–79]; P < 0.001); however, median SpO2/FiO2 was higher (329.4 [IQR 180–411.1] vs. 246.7 [IQR 151.1–320.5]; P < 0.001) with closed–loop oxygen control. With closed–loop oxygen control, the median number of manual adjustments reduced (0.0 [IQR 0.0–0.0] vs. 1 [IQR 0.0–2.2]; P < 0.001).Conclusion: Closed-loop oxygen control enhances oxygen therapy in pediatric patients undergoing IMV for AHRF, potentially leading to more efficient utilization of oxygen. This technology also decreases the necessity for manual adjustments, which could reduce the workloads of healthcare providers.Clinical Trial Registration: This research has been submitted to ClinicalTrials.gov (NCT05714527).

13 May 2021 in The Journal of Vascular Access
Verified
Journal Article
Closed access
PDF file
GCGokhan Ceylan
Gokhan Ceylan
STSevgi Topal
Sevgi Topal
NTNuriye Turgut
Nuriye Turgut
NONihal Ozdamar
Nihal Ozdamar
YOYeliz Oruc
Yeliz Oruc
İDİlker Devrim
İlker Devrim
Central line-associated bloodstream infection is one of the four primary health-care-associated infections applicable to pediatric intensive care units defined by The Centers for Disease Control and Prevention. According to current guidelines, it is essential to flush vascular access devices before each infusion to assess catheter function and prevent catheter-related complications. This prospective trial aimed to assess the potential differences between pre-filled and manually prepared saline syringe use during vascular access device management in a pediatric intensive care unit. Volunteered registered pediatric intensive care unit nurses were asked to implement the flushing solution to an extension line of a central venous catheter in vitro. After the randomization process with opaque sealed envelopes, they have started either with manual preparation or used sterile pre-filled saline syringes. Sterile application steps forms were used for monitoring the manual preparation of saline syringes versus the pre-filled saline syringes phase. Each volunteer repeated the steps for 3, 5, and 10 mL syringe volumes with the manually prepared and pre-filled saline syringes. After completing the procedures, failed steps and durations were transferred into a database to be analyzed by a blinded investigator. A total of 41 nurses volunteered and 123 forms for three attempts per one nurse were filled for each group. In the manual preparation group, the number of at least one failure in the necessary steps was 89 (72.3%) and the same number in the pre-filled syringe group was 6 (4.9%), and significantly lower in the pre-filled saline syringe group (p < 0.001). The overall time for preparing to flush was 86.0 ± 22.3 s (ranging from 46 to 173 s) for manual prepared syringes and 35.2 ± 9.4 s (ranging from 18 to 100 s) (p < 0.001) for pre-filled saline syringes. Our results demonstrate that the risk for breaking the aseptic no-touch technic was higher in the manual preparation group. We have also demonstrated that the flushing time was shorter with pre-filled syringes compared to manually prepared ones, which may contribute to decreasing the workload of the nurses and may increase the quality of care in the intensive care units. The use of pre-filled saline syringes may decrease the central line-associated bloodstream infections incidence and may increase the quality of care by saving extra time in the pediatric intensive care unit.