Shunxing Bao

Dr. Shunxing Bao

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2023 in Medical Image Analysis
Verified
Journal Article
Closed access
XYXin Yu
Xin Yu
QYQi Yang
Qi Yang
YZYinchi Zhou
Yinchi Zhou
LCLeon Y. Cai
Leon Y. Cai
RGRiqiang Gao
Riqiang Gao
YTYucheng Tang
Yucheng Tang

9 February 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YTYucheng Tang
Yucheng Tang
RGRiqiang Gao
Riqiang Gao
SHShizhong Han
Shizhong Han
YCYunqiang Chen
Yunqiang Chen
DGDashan Gao
Dashan Gao
BLBennett A. Landman
Bennett A. Landman
Body part regression is a promising new technique that enables content navigation through self-supervised learning. Using this technique, the global quantitative spatial location for each axial view slice is obtained from computed tomography (CT). However, it is challenging to define a unified global coordinate system for body CT scans due to the large variabilities in image resolution, contrasts, sequences, and patient anatomy. Therefore, the widely used supervised learning approach cannot be easily deployed. To address these concerns, we propose an annotation-free method named blind-unsupervised-supervision network (BUSN). The contributions of the work are in four folds: (1) 1030 multi-center CT scans are used in developing BUSN without any manual annotation. (2) the proposed BUSN corrects the predictions from unsupervised learning and uses the corrected results as the new supervision; (3) to improve the consistency of predictions, we propose a novel neighbor message passing (NMP) scheme that is integrated with BUSN as a statistical learning based correction; and (4) we introduce a new pre-processing pipeline with inclusion of the BUSN, which is validated on 3D multi-organ segmentation. The proposed method is trained on 1,030 whole body CT scans (230,650 slices) from five datasets, as well as an independent external validation cohort with 100 scans. From the body part regression results, the proposed BUSN achieved significantly higher median R-squared score (=0.9089) than the state-of-the-art unsupervised method (=0.7153). When introducing BUSN as a preprocessing stage in volumetric segmentation, the proposed pre-processing pipeline using BUSN approach increases the total mean Dice score of the 3D abdominal multi-organ segmentation from 0.7991 to 0.8145.

8 August 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
BCBinjun Chen
Binjun Chen
YLYike Li
Yike Li
Yu SunYu Sun
Yu Sun
HSHaojie Sun
Haojie Sun
YWYanmei Wang
Yanmei Wang
DRDongdong Ren
Dongdong Ren
Background: Temporal bone computed tomography (CT) helps diagnose chronic otitis media (COM). However, its interpretation requires training and expertise. Artificial intelligence (AI) can help clinicians evaluate COM through CT scans, but existing models lack transparency and may not fully leverage multidimensional diagnostic information. Objective: We aimed to develop an explainable AI system based on 3D convolutional neural networks (CNNs) for automatic CT-based evaluation of COM. Methods: Temporal bone CT scans were retrospectively obtained from patients operated for COM between December 2015 and July 2021 at 2 independent institutes. A region of interest encompassing the middle ear was automatically segmented, and 3D CNNs were subsequently trained to identify pathological ears and cholesteatoma. An ablation study was performed to refine model architecture. Benchmark tests were conducted against a baseline 2D model and 7 clinical experts. Model performance was measured through cross-validation and external validation. Heat maps, generated using Gradient-Weighted Class Activation Mapping, were used to highlight critical decision-making regions. Finally, the AI system was assessed with a prospective cohort to aid clinicians in preoperative COM assessment. Results: Internal and external data sets contained 1661 and 108 patients (3153 and 211 eligible ears), respectively. The 3D model exhibited decent performance with mean areas under the receiver operating characteristic curves of 0.96 (SD 0.01) and 0.93 (SD 0.01), and mean accuracies of 0.878 (SD 0.017) and 0.843 (SD 0.015), respectively, for detecting pathological ears on the 2 data sets. Similar outcomes were observed for cholesteatoma identification (mean area under the receiver operating characteristic curve 0.85, SD 0.03 and 0.83, SD 0.05; mean accuracies 0.783, SD 0.04 and 0.813, SD 0.033, respectively). The proposed 3D model achieved a commendable balance between performance and network size relative to alternative models. It significantly outperformed the 2D approach in detecting COM (P≤.05) and exhibited a substantial gain in identifying cholesteatoma (P<.001). The model also demonstrated superior diagnostic capabilities over resident fellows and the attending otologist (P<.05), rivaling all senior clinicians in both tasks. The generated heat maps properly highlighted the middle ear and mastoid regions, aligning with human knowledge in interpreting temporal bone CT. The resulting AI system achieved an accuracy of 81.8% in generating preoperative diagnoses for 121 patients and contributed to clinical decision-making in 90.1% cases. Conclusions: We present a 3D CNN model trained to detect pathological changes and identify cholesteatoma via temporal bone CT scans. In both tasks, this model significantly outperforms the baseline 2D approach, achieving levels comparable with or surpassing those of human experts. The model also exhibits decent generalizability and enhanced comprehensibility. This AI system facilitates automatic COM assessment and shows promising viability in real-world clinical settings. These findings underscore AI’s potential as a valuable aid for clinicians in COM evaluation. Trial Registration: Chinese Clinical Trial Registry ChiCTR2000036300; https://www.chictr.org.cn/showprojEN.html?proj=58685

20 November 2019 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
YHYuankai Huo
Yuankai Huo
YTYucheng Tang
Yucheng Tang
YCYunqiang Chen
Yunqiang Chen
DGDashan Gao
Dashan Gao
SHShizhong Han
Shizhong Han
BLBennett A. Landman
Bennett A. Landman
<!-- *** Custom HTML *** --> Tissue window filtering has been widely used in deep learning for computed tomography (CT) image analyses to improve training performance (e.g., soft tissue windows for abdominal CT). However, the effectiveness of tissue window normalization is questionable since the generalizability of the trained model might be further harmed, especially when such models are applied to new cohorts with different CT reconstruction kernels, contrast mechanisms, dynamic variations in the acquisition, and physiological changes. We evaluate the effectiveness of both with and without using soft tissue window normalization on multisite CT cohorts. Moreover, we propose a stochastic tissue window normalization (SWN) method to improve the generalizability of tissue window normalization. Different from the random sampling, the SWN method centers the randomization around the soft tissue window to maintain the specificity for abdominal organs. To evaluate the performance of different strategies, 80 training and 453 validation and testing scans from six datasets are employed to perform multiorgan segmentation using standard 2D U-Net. The six datasets cover the scenarios, where the training and testing scans are from (1) same scanner and same population, (2) same CT contrast but different pathology, and (3) different CT contrast and pathology. The traditional soft tissue window and nonwindowed approaches achieved better performance on (1). The proposed SWN achieved general superior performance on (2) and (3) with statistical analyses, which offers better generalizability for a trained model.

15 February 2021 in Proceedings of SPIE
Verified
Conference Paper
Closed access
PDF file
YTYucheng Tang
Yucheng Tang
RGRiqiang Gao
Riqiang Gao
HLHo Hin Lee
Ho Hin Lee
ZXZhoubing Xu
Zhoubing Xu
BSBrent V. Savoie
Brent V. Savoie
BLBennett A. Landman
Bennett A. Landman
Renal segmentation on contrast-enhanced computed tomography (CT) provides distinct spatial context and morphology. Current studies for renal segmentations are highly dependent on manual efforts, which are time-consuming and tedious. Hence, developing an automatic framework for the segmentation of renal cortex, medulla and pelvicalyceal system is an important quantitative assessment of renal morphometry. Recent innovations in deep methods have driven performance toward levels for which clinical translation is appealing. However, the segmentation of renal structures can be challenging due to the limited field-of-view (FOV) and variability among patients. In this paper, we propose a method to automatically label the renal cortex, the medulla and pelvicalyceal system. First, we retrieved 45 clinically-acquired deidentified arterial phase CT scans (45 patients, 90 kidneys) without diagnosis codes (ICD-9) involving kidney abnormalities. Second, an interpreter performed manual segmentation to pelvis, medulla and cortex slice-by-slice on all retrieved subjects under expert supervision. Finally, we proposed a patch-based deep neural networks to automatically segment renal structures. Compared to the automatic baseline algorithm (3D U-Net) and conventional hierarchical method (3D U-Net Hierarchy), our proposed method achieves improvement of 0.7968 to 0.6749 (3D U-Net), 0.7482 (3D U-Net Hierarchy) in terms of mean Dice scores across three classes (p-value < 0.001, paired t-tests between our method and 3D U-Net Hierarchy). In summary, the proposed algorithm provides a precise and efficient method for labeling renal structures.

19 May 2022 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
QYQi Yang
Qi Yang
XYXin Yu
Xin Yu
HLHo Hin Lee
Ho Hin Lee
YTYucheng Tang
Yucheng Tang
SBShunxing Bao
Shunxing Bao
BLBennett A. Landman
Bennett A. Landman
Estimating volumes and masses of total body components is important for research of cancer, joint replacement, and exercise physiology.1 Full body CT scans can be used to calculate whole body compositions directly. However, it is hard to acquire a typical full body CT in the usual medical context due to the intense radiology dose. Mourtzakis et al.2 proposed that body components measured on abdomen or thigh slices are highly correlated with the mass of whole-body tissues. Thus, accurate segmentation of thigh slices can quantify tissue area properties to estimate body composition without requiring additional irradiation or examinations. Thus, this paper aims to segment muscle, fat, and bones from 2D thigh and lower leg CT slices.