Xiaoming Gong

Xiaoming Gong


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Journal of Chemistry
Verified
Journal Article
Open access
PDF file
XGXiaoming Gong
Xiaoming Gong
KLKai Li
Kai Li
WXWenjuan Xu
Wenjuan Xu
LJLiming Jin
Liming Jin
MLMengxiao Liu
Mengxiao Liu
GTGuoning Tian
Guoning Tian
In this study, a rough, cheap, easy-made wooden-tip-based solid-phase microextraction (SPME) probe was first developed for simultaneous determination of 4 nitrofuran metabolite derivatives in complex food matrices via LC-MS/MS. A simple dip-coating method was used to coat wooden tips with biocompatible polyacrylonitrile (PAN) and N-vinylpyrrolidone-co-divinylbenzene, also known as HLB particles, which served as the extractive substrate in the proposed device. Compared with the traditional solid-phase extraction (SPE) method, the proposed device shortens sample clean-up time, reduces solvent consumption, and decreases testing costs. In addition, the main parameters affecting the SPME procedure efficiency were investigated in detail and the optimal conditions were found. The method was validated using three different food matrixes (pork, croaker, and honey) by spiking with the four metabolites at 0.5, 1.0, and 5.0μg/kg, as well as their internal standards. The average recovery of all nitrofuran metabolite derivatives ranges from 97.4109.5 (pork), 87.5112.7 (croaker), and 98.6109.0 (honey). Relative standard deviations were all <10 for intraday and interday precision. The values of limit of detection and limit of quantification were, respectively, ranging from 0.011 to 0.123 and 0.033 to 0.369μg/kg (pork), 0.009 to 0.112 and 0.027 to 0.339μg/kg (croaker), and 0.010 to 0.131 and 0.030 to 0.293μg/kg (honey). The presented method was applied to the analysis of real positive samples.

31 March 2017 in Journal of Regulatory Science
Verified
Journal Article
Open access
PDF file
XGXiaoming Gong
Xiaoming Gong
RMRonghui Ma
Ronghui Ma
KLKai Li
Kai Li
HZHongwei Zhang
Hongwei Zhang
ZWZhenxing Wu
Zhenxing Wu
HZHan Zhao
Han Zhao
A multi-residue procedure with liquid chromatography-tandem mass spectrometry analysis was developed to simultaneously detect the presence of 4 diarrheic shellfish poisoning toxins, 14 sulfonamides, chloramphenicol and thiamphenicol in shellfish tissues. Samples were first purified by a modified rapid procedure and separated on a ZOBRAX Eclipse Plus C18 column and quantified using electron spray ionization-mass spectrometry-mass spectrometry. The results showed that the limits of quantification (LOQ) of SPX1, OA-C, GYM, and PTX-2 were 1.0, 2, 0.5 and 2 μg/kg, respectively. The LOQ for the antibiotics was below acceptable limits established by most countries. Compared to the external standard method, this matrix matched the calibration method effectively, overcame the matrix effects and gave better quantitative results. Recoveries of spiked compounds ranged between 67.6% and 109.8%, with relative standard deviations below 15% for most target analytes. Only sulfathiazole had a %RSD of 18.6% at the lowest spiked concentration. The proposed method was accurate, rapid and reliable. https://doi.org/10.21423/jrs-v05n01p009 (DOI assigned 4/17/2019)

24 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
KLKai Li
Kai Li
XGXiaoming Gong
Xiaoming Gong
Liming JinLiming Jin
Liming Jin
MLMengxiao Liu
Mengxiao Liu
MHMengmeng Hua
Mengmeng Hua
This study presents an innovative analytical method for the detection and quantification of 14 β-agonists in pork using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method involves the use of a solid phase microextraction (SPME) probe, consisting of a wooden tip coated with polyacrylonitrile (PAN) and molecularly imprinted polymer (MIP). This probe has been integrated into an automated extraction device, designed in our laboratory to extract the target analytes prior to LC-MS/MS analysis. Compared to the traditional solid-phase extraction (SPE) procedure, the proposed approach significantly reduces the costs related to adsorbent ma-terial and solvent consumption, and shortens purification time, thereby reducing both the tech-nical workload and associated expenses. The methodology has been carefully validated in ac-cordance with the National Standard of the People's Republic of China (GB/T 22286-2008), evalu-ating key parameters including the limit of detection (LOD), limit of quantification (LOQ), matrix effects, linearity, and both intra-day and inter-day precision. The average recovery rates for all β-agonists were observed to lie between 71.6% and 82.2%, with relative standard deviations (RSDs) consistently below 15% for both types of precision. The LOD and LOQ values were found to range from 0.09 to 0.39 μg/kg and 0.27 to 0.99 μg/kg, respectively. In terms of accurate detection of positive samples, the developed method demonstrated a closer approximation to the true value of the sample compared to the National Standard method GB/T 31658.22-2022. Overall, the proposed method exhibits substantial promise for the routine assessment of β-agonists in pork and presents a practical alternative for compliance monitoring in regulatory settings.