Evidence of the benefit on propioceptive neuromuscular facilitation for reducing falls in older people does not exist. The aim of this study is to evaluate the effects of propioceptive facilitation over falls and biomechanical variables, in comparison to standard treatment and control groups. Series cases comparative for the 24 participants were recruited and randomnly assigned to 3 groups. Group 1, propioceptive neuromuscular facilitation, group 2, standard treatment, and 3 control. Falls and biomechanic variables were measured before and after. Chi(2) was used for falls and multiple regression for biomechanical variables, Participants had similar falls in previous year. Women had higher falls in a relation 7:1 women-men. After intervention, there was no difference between 3 groups. A correlation exista between muscular strength and gait speed with one foot position time r(2) = 0.67, p = 0.02. Improving 1kilogram-force of muscular strength of pelvic limb and 0.1meter/second in gait speed, balance (unipodal position time) increases balance by 11.3%. After 3 months of intervention group 2 got 7.9kg-force and 0.26m/s of profit, while group 1 had 4.1kg-force and 0.15m/s and control group 2.4kg-force and 0.1m/s.
Body composition assessment using instruments such as dual X-ray densitometry (DXA) can be complex and their use is often limited to research. This cross-sectional study aimed to develop and validate a densitometric method for fat mass (FM) estimation using 3D cameras. Using two such cameras, stereographic images, and a mesh reconstruction algorithm, 3D models were obtained. The FM estimations were compared using DXA as a reference. In total, 28 adults, with a mean BMI of 24.5 (±3.7) kg/m2 and mean FM (by DXA) of 19.6 (±5.8) kg, were enrolled. The intraclass correlation coefficient (ICC) for body volume (BV) was 0.98–0.99 (95% CI, 0.97–0.99) for intra-observer and 0.98 (95% CI, 0.96–0.99) for inter-observer reliability. The coefficient of variation for kinetic BV was 0.20 and the mean difference (bias) for BV (liter) between Bod Pod and Kinect was 0.16 (95% CI, −1.2 to 1.6), while the limits of agreement (LoA) were 7.1 to −7.5 L. The mean bias for FM (kg) between DXA and Kinect was −0.29 (95% CI, −2.7 to 2.1), and the LoA was 12.1 to −12.7 kg. The adjusted R2 obtained using an FM regression model was 0.86. The measurements of this 3D camera-based system aligned with the reference measurements, showing the system’s feasibility as a simpler, more economical screening tool than current systems.
About Me
Physical therapy and Rehabilitation, Health instruments validation.
Physical therapy and Rehabilitation, Health instruments validation.