Purpose: To quantify needle placement accuracy of magnetic resonance image (MRI)‐guided core needle biopsy of the prostate.Materials and Methods: A total of 10 biopsies were performed with 18‐gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intraprocedural coherent gradient echo images. The source of these errors was subsequently investigated by measuring displacement caused by needle deflection and needle susceptibility artifact shift in controlled phantom studies. Needle placement error due to misalignment of the needle template guide was also evaluated.Results: The mean and standard deviation (SD) of errors in targeted biopsies was 6.5 ± 3.5 mm. Phantom experiments showed significant placement error due to needle deflection with a needle with an asymmetrically beveled tip (3.2–8.7 mm depending on tissue type) but significantly smaller error with a symmetrical bevel (0.6–1.1 mm). Needle susceptibility artifacts observed a shift of 1.6 ± 0.4 mm from the true needle axis. Misalignment of the needle template guide contributed an error of 1.5 ± 0.3 mm.Conclusion: Needle placement error was clinically significant in MRI‐guided biopsy for diagnosis of prostate cancer. Needle placement error due to needle deflection was the most significant cause of error, especially for needles with an asymmetrical bevel. J. Magn. Reson. Imaging 2007;26:688–694.
Background: Adaptive radiation therapy (ART) offers a dynamic approach to address structural and spatial changes that occur during radiotherapy (RT) for locally advanced head and neck cancers. The integration of daily ART with Cone-Beam CT (CBCT) imaging presents a solution to enhance the therapeutic ratio by addressing inter-fractional changes. Methods: We evaluated the initial clinical experience of daily ART for patients with head and neck cancer using an online adaptive platform with intelligence-assisted workflows on daily CBCT. Treatment included auto-contour and structure deformation of Organs at Risk (OARs) and target structures, with adjustments by the treating physician. Two plans were generated: one based on the initial CT simulation with the edited structures (scheduled) and a re-optimized plan (adaptive). Both plans were evaluated and the superior one approved and delivered. Clinical and dosimetric outcomes were reviewed. Results: Twenty two patients with head and neck cancers (7 Nasopharynx, 6 Oropharynx, 1 oral cavity, 8 larynx) stages I-IVA were treated with daily ART. 770 adaptive and scheduled radiotherapy plans were generated. 703 (91.3%) adaptive plans were chosen. Median time to deliver ART was 20 minutes (range: 18-23). Adaptive compared to scheduled plans demonstrated improved mean V95 values for the PTV70, PTV59.5, and PTV56 by 1.2%, 7.2%, and 6.0% respectively and a mean 1.4% lower maximum dose in PTV70. Fourteen of 17 OARs demonstrated improved dosimetry with adaptation, with select OARs reaching statistical significance. At a median follow up of 14.1 months, local control was 95.5%, two patients developed metastatic disease and four patients died. 9.1% of patients had acute grade 3 dysphagia and 13.6% had grade 2 chronic xerostomia. Discussion: These findings provide real world evidence of the feasibility and dosimetric benefit of incorporating daily ART on CBCT in the treatment of head and neck cancer. Prospective study is needed to determine if these dosimetric improvements translate into improved outcomes.
The clinical development of new drugs with radiation appears to be limited. We hypothesised that phase I clinical trials with radiation therapy (RT) are initiated too late into a new drug's lifetime, impeding the ability to complete RT-drug development programmes before patent expiration. We identified novel drug-radiation phase I combination trials performed between 1980 and 2012 within the PubMed and ClinicalTrials.gov databases. Data gathered for each drug included: date the initial phase I trial with/without RT was opened/published, date of the published positive phase III trials, and patent expiration dates. Lag time was defined as the interval between opening of the phase I trial without RT and the opening of the phase I with RT. Linear regression was used to model how the lag time has changed over time. The median lag time was 6 years. The initial phase I trial with RT was typically published 2 years after the first published positive phase III trial and 11 years before patent expiration. Using a best-fit linear model, lag time decreased from 10 years for phase I trials published in 1990 to 5 years in 2005 (slope significantly non-zero, P<0.001). Clinical drug development with RT commences late in the life cycle of anti-cancer agents. Taking into account the additional time required for late-phase clinical trials, the delay in initiating clinical testing of drug-RT combinations discourages drug companies from further pursuing RT-based development. Encouragingly, lag time appears to be decreasing. Further reduction in lag time may accelerate RT-based drug development, potentially improving patient outcomes.
The advent of commercially available vertical CT systems has renewed interest in gantry-less proton therapy (PT), in which patients are treated in an upright position using a fixed beamline and robotic positioning. This study evaluates the feasibility, safety, and preliminary efficacy of novel gantry-less image-guided adaptive PT (IGAPT) for recurrent head and neck (HN) and brain malignancies. A planned interim analysis was performed on 20 adult patients with recurrent HN (80 %) and brain (20 %) cancers, median age 62 years, with Eastern Cooperative Oncology Group (ECOG) performance status ≤2. Patients underwent upright and supine imaging and simulation, followed by treatment planning comparing upright PT to conventional supine intensity-modulated radiotherapy (IMRT). Dosimetric analyses focused on organ-at-risk (OAR) sparing and target coverage. Toxicities were assessed prospectively every three months using the Common Terminology Criteria for Adverse Events (CTCAE). Gantry-less PT demonstrated significant dosimetric advantages over photon IMRT, including reduced doses to critical OARs including brainstem (6 Gy(RBE) vs. 19.1 Gy; p < 0.001) and spinal cord (12.5 Gy(RBE) vs. 18.3 Gy; p < 0.006). At 3-month follow-up (n = 14), a complete response was observed in 64.3 % of evaluable patients and a partial response in 21.4 %. Most toxicities were mild-to-moderate (grades 1-2), primarily dermatitis (55 %), fatigue (45 %), and mucositis (31.3 %). Grade 3 toxicities occurred in four patients (20 %). There were no device-related deaths. This first clinical evaluation of a novel gantry-less IGAPT system confirms its feasibility, safety, and promising efficacy for recurrent HN and brain cancer, with superior dosimetry and high local control rates. Its cost-effective design may improve global access to the IGAPT.
Sarcoma classification is challenging and can lead to treatment delays. Previous studies used DNA aberrations and machine-learning classifiers based on methylation profiles for diagnosis. We aimed to classify sarcomas by analyzing methylation signatures obtained from low-coverage whole-genome sequencing, which also identifies copy-number alterations. DNA was extracted from 23 suspected sarcoma samples and sequenced on an Oxford Nanopore sequencer. The methylation-based classifier, applied in the nanoDx pipeline, was customized using a reference set based on processed Illumina-based methylation data. Classification analysis utilized the Random Forest algorithm and t-distributed stochastic neighbor embedding, while copy-number alterations were detected using a designated R package. Out of the 23 samples encompassing a restricted range of sarcoma types, 20 were successfully sequenced, but two did not contain tumor tissue, according to the pathologist. Among the 18 tumor samples, 14 were classified as reported in the pathology results. Four classifications were discordant with the pathological report, with one compatible and three showing discrepancies. Improving tissue handling, DNA extraction methods, and detecting point mutations and translocations could enhance accuracy. We envision that rapid, accurate, point-of-care sarcoma classification using nanopore sequencing could be achieved through additional validation in a diverse tumor cohort and the integration of methylation-based classification and other DNA aberrations.