Wind power generation is a renewable energy source, and its power output is influenced by multiple factors such as wind speed, direction, meteorological conditions, and the characteristics of wind turbines. Therefore, accurately predicting wind power is crucial for the grid operation and maintenance management of wind power plants. This paper proposes a hybrid model to improve the accuracy of wind power prediction. Accurate wind power forecasting is critical for the safe operation of power systems. To improve the accuracy of wind power prediction, this paper proposes a hybrid model incorporating variational modal decomposition (VMD), a Sparrow Search Algorithm (SSA), and a temporal-convolutional-network-based bi-directional gated recurrent unit (TCN-BiGRU). The model first uses VMD to break down the raw power data into several modal components, and then it builds an SSA-TCN-BIGRU model for each component for prediction, and finally, it accumulates all the predicted components to obtain the wind power prediction results. The proposed short-term wind power prediction model was validated using measured data from a wind farm in China. The proposed VMD-SSA-TCN-BiGRU forecasting framework is compared with benchmark models to verify its practicability and reliability. Compared with the TCN-BiGRU, the symmetric mean absolute percentage error, the mean absolute error, and the root mean square error of the VMD-SSA-TCN-BiGRU model reduced by 34.36%, 49.14%, and 55.94%.
Anomaly detection problems in industrial control systems (ICSs) are always tackled by a network traffic monitoring scheme. However, traffic-based anomaly detection systems may be deceived by anomalous behaviors that mimic normal system activities and fail to achieve effective anomaly detection. In this work, we propose a novel solution to this problem based on measurement data. The proposed method combines a one-dimensional convolutional neural network (1DCNN) and a bidirectional long short-term memory network (BiLSTM) and uses particle swarm optimization (PSO), which is called PSO-1DCNN-BiLSTM. It enables the system to detect any abnormal activity in the system, even if the attacker tries to conceal it in the system’s control layer. A supervised deep learning model was generated to classify normal and abnormal activities in an ICS to evaluate the method’s performance. This model was trained and validated against the open-source simulated power system dataset from Mississippi State University. In the proposed approach, we applied several deep-learning models to the dataset, which showed remarkable performance in detecting the dataset’s anomalies, especially stealthy attacks. The results show that PSO-1DCNN-BiLSTM performed better than other classifier algorithms in detecting anomalies based on measured data.
The integration of communication networks and the internet of industrial control in Industrial Control System (ICS) increases their vulnerability to cyber attacks, causing devastating outcomes. Traditional Intrusion Detection Systems (IDS) largely rely on predefined models and are trained mostly on specific cyber attacks, which means the traditional IDS cannot cope with unknown attacks. Additionally, most IDS do not consider the imbalanced nature of ICS datasets, thus suffering from low accuracy and high False Positive Rates when being put to use. In this paper, we propose the NCO–double-layer DIFF_RF–OPFYTHON intrusion detection method for ICS, which consists of NCO modules, double-layer DIFF_RF modules, and OPFYTHON modules. Detected traffic will be divided into three categories by the double-layer DIFF_RF module: known attacks, unknown attacks, and normal traffic. Then, the known attacks will be classified into specific attacks by the OPFYTHON module according to the feature of attack traffic. Finally, we use the NCO module to improve the model input and enhance the accuracy of the model. The results show that the proposed method outperforms traditional intrusion detection methods, such as XGboost and SVM. The detection of unknown attacks is also considerable. The accuracy of the dataset used in this paper reaches 98.13%. The detection rates for unknown attacks and known attacks reach 98.21% and 95.1%, respectively. Moreover, the method we proposed has achieved suitable results on other public datasets.
Aiming at the imbalance of industrial control system data and the poor detection effect of industrial control intrusion detection systems on network attack traffic problems, we propose an ETM-TBD model based on hybrid machine learning and neural network models. Aiming at the problem of high dimensionality and imbalance in the amount of sample data in the massive data of industrial control systems, this paper proposes an IG-based feature selection method and an oversampling method for SMOTE. In the ETM-TBD model, we propose a hyperparameter optimization method based on Bayesian optimization used to optimize the parameters of the four basic machine learners in the model. By introducing a multi-head-attention mechanism, the Transformer module increases the attention between local features and global features, enabling the discovery of the internal relationship between features. Additionally, the BiGRU is used to preserve the temporal features of the dataset, while the DNN is used to extract deeper features. Finally, the SoftMax classifier is used to classify the output. By analyzing the results of the comparison and ablation experiments, it can be concluded that the F1-score of the ETM-TBD model on a robotic arm dataset is 0.9665 and the model has very low FNR and FPR scores of 0.0263 and 0.0081, respectively. It can be seen that the model in this paper is better than the traditional single machine learning algorithm as well as the algorithm lacking any of the modules.
The current mainstream intrusion detection models often have a high false negative rate, significantly affecting intrusion detection systems’ (IDSs) practicability. To address this issue, we propose an intrusion detection model based on a multi-scale one-dimensional convolutional neural network module (MS1DCNN), an efficient channel attention module (ECA), and two bidirectional long short-term memory modules (BiLSTMs). The proposed hybrid MS1DCNN-ECA-BiLSTM model uses the MS1DCNN module to extract features with a different granularity from the input data and uses the ECA module to enhance the weight of important features. Finally, the model carries out sequence learning through two BiLSTM layers. We use the dung beetle optimizer (DBO) to optimize the hyperparameters in the model to obtain better classification results. Additionally, we use the synthetic minority oversampling technique (SMOTE) to fill several samples to reduce the local false negative rate. In this paper, we train and test the model using accurate network data from a water storage industrial control system. In the multi-classification experiment, the model’s accuracy was 97.04%, the precision was 97.17%, and the false negative rate was 2.95%; in the binary classification experiment, the accuracy and false negative rate were 99.30% and 0.7%. Compared with other mainstream methods, our model has a higher score. This study provides a new algorithm for the intrusion detection of industrial control systems.