In this 14th document in a series of papers entitled “Controversies in Endoscopic Ultrasound” we discuss various aspects of EUS-guided biliary drainage that are debated in the literature and in practice. Endoscopic retrograde cholangiography is still the reference technique for therapeutic biliary access, but EUS-guided techniques for biliary access and drainage have developed into safe and highly effective alternative options. However, EUS-guided biliary drainage techniques are technically demanding procedures for which few training models are currently available. Different access routes require modifications to the basic technique and specific instruments. In experienced hands, percutaneous transhepatic cholangiodrainage is also a good alternative. Therefore, in this paper, we compare arguments for different options of biliary drainage and different technical modifications.
1 January 2021 in Saudi Journal of Medicine & Medical Sciences
Background: Laparoscopic sleeve gastrectomy (LSG) is the most commonly performed surgery to treat morbid obesity. Post-LSG leak and stenosis are serious complications that can be associated with significant morbidity and mortality. Objective: The objective was to report the efficacy and safety profile of using specifically designed fully covered self-expandable metallic stent for the treatment of post-LSG complications. Methods: This retrospective study included adult patients who underwent placement of a fully covered esophagogastric, self-expandable metallic stent for post-LSG leak or stenosis. The procedure was carried out at King Abdulaziz University Hospital, Jeddah, Saudi Arabia, between September 2017 and May 2019. Data regarding demographics, indication for stenting, size of the stent, procedural success and poststenting adverse events were collected. Results: A total of 14 patients met the inclusion criteria, with indication for endoscopic stenting being post-LSG leak in 11 patients and stenosis in 3 patients. The technical success rate of self-expandable metallic stent placement was 100%, and the clinical success was 85.7% (12 of 14 patients). Nausea (71.4%) and vomiting (85.7%) were the most frequent mild adverse events reported. Stent-induced esophageal stricture was the only major adverse event reported in two patients. Conclusion: Placement of specifically designed self-expandable metallic stent for the treatment of post-LSG leak and stenosis is an effective and safe approach. Further studies with larger cohorts are needed to assess the optimal duration needed to treat such complications.
A 25-year-old obese woman experienced ischemic renal injury as a complication of intragastric balloon (IGB) insertion for weight reduction. Although IGB is associated with a low risk of renal injury in the form of acute renal failure, this presentation has never been reported. The patient responded well to treatment, with complete clinical and radiologic resolution after balloon removal. She did not have an apparent cause of renal ischemia other than a significant compression of the renal vessels by the balloon as seen on imaging.