Electrical impedance tomography (EIT) is a non-invasive technique for visualizing the internal structure of a human body. Capacitively coupled electrical impedance tomography (CCEIT) is a new contactless EIT technique that can potentially be used as a wearable device. Recent studies have shown that a machine learning-based approach is very promising for EIT image reconstruction. Most of the studies concern models containing up to 22 electrodes and focus on using different artificial neural network models, from simple shallow networks to complex convolutional networks. However, the use of convolutional networks in image reconstruction with a higher number of electrodes requires further investigation. In this work, two different architectures of artificial networks were used for CCEIT image reconstruction: a fully connected deep neural network and a conditional generative adversarial network (cGAN). The training dataset was generated by the numerical simulation of a thorax phantom with healthy and illness-affected lungs. Three kinds of illnesses, pneumothorax, pleural effusion, and hydropneumothorax, were modeled using the electrical properties of the tissues. The thorax phantom included the heart, aorta, spine, and lungs. The sensor with 32 area electrodes was used in the numerical model. The ECTsim custom-designed toolbox for Matlab was used to solve the forward problem and measurement simulation. Two artificial neural networks were trained with supervision for image reconstruction. Reconstruction quality was compared between those networks and one-step algebraic reconstruction methods such as linear back projection and pseudoinverse with Tikhonov regularization. This evaluation was based on pixel-to-pixel metrics such as root-mean-square error, structural similarity index, 2D correlation coefficient, and peak signal-to-noise ratio. Additionally, the diagnostic value measured by the ROC AUC metric was used to assess the image quality. The results showed that obtaining information about regional lung function (regions affected by pneumothorax or pleural effusion) is possible using image reconstruction based on supervised learning and deep neural networks in EIT. The results obtained using cGAN are strongly better than those obtained using a fully connected network, especially in the case of noisy measurement data. However, diagnostic value estimation showed that even algebraic methods allow us to obtain satisfactory results.
26 August 2022 in Measurement Science and Technology
Three-dimensional (3D) visualization has provoked interest in electrical capacitance tomography (ECT) due to recent progress in the development of capacitance measurement circuits and data-acquisition systems. This paper proposes image reconstruction using spatio-temporal sampling in the Z-axis for 3D ECT to improve spatial image resolution. In a typical application of ECT, multi-phase flow imaging is performed through two-dimensional (2D) data acquisition and 2D reconstruction of image frames over time. In the presented method, a volume of interest (VOI) is reconstructed from several time samples obtained using a 3D sensor. The procedure of Jacobian matrix extension for the spatio-temporal data is described. The experiments were carried out using the EVT4 system and a 32-electrode sensor. The reconstruction results of a VOI from a single 3D measurement and spatio-temporal sampling are compared. A phantom for 3D imaging to assess spatial image resolution using a modulation transfer function is proposed.
This study investigated the potential of machine-learning-based stroke image reconstruction in capacitively coupled electrical impedance tomography. The quality of brain images reconstructed using the adversarial neural network (cGAN) was examined. The big data required for supervised network training were generated using a two-dimensional numerical simulation. The phantom of an axial cross-section of the head without and with impact lesions was an average of a three-centimeter-thick layer corresponding to the height of the sensing electrodes. Stroke was modeled using regions with characteristic electrical parameters for tissues with reduced perfusion. The head phantom included skin, skull bone, white matter, gray matter, and cerebrospinal fluid. The coupling capacitance was taken into account in the 16-electrode capacitive sensor model. A dedicated ECTsim toolkit for Matlab was used to solve the forward problem and simulate measurements. A conditional generative adversarial network (cGAN) was trained using a numerically generated dataset containing samples corresponding to healthy patients and patients affected by either hemorrhagic or ischemic stroke. The validation showed that the quality of images obtained using supervised learning and cGAN was promising. It is possible to visually distinguish when the image corresponds to the patient affected by stroke, and changes caused by hemorrhagic stroke are the most visible. The continuation of work towards image reconstruction for measurements of physical phantoms is justified.
Electrical capacitance tomography (ECT) is a technique of imaging the distribution of permittivity inside an object under test. Capacitance is measured between the electrodes surrounding the object, and the image is reconstructed from these data by solving the inverse problem. Although both sinusoidal excitation and pulse excitation are used in the sensing circuit, only the AC method is used to measure both components of complex capacitance. In this article, a novel method of complex capacitance measurement using pulse excitation is proposed for ECT. The real and imaginary components are calculated from digital samples of the integrator response. A pulse shape in the front-end circuit was analyzed using the Laplace transform. The numerical simulations of the electric field inside the imaging volume as well as simulations of a pulse excitation in the front-end circuit were performed. The calculation of real and imaginary components using digital samples of the output signal was verified. The permittivity and conductivity images reconstructed for the test object were presented. The method enables imaging of permittivity and conductivity spatial distributions using capacitively coupled electrodes and may be an alternative measurement method for ECT as well as for electrical impedance tomography.
1 October 2021 in Proceedings of the National Academy of Sciences, India Section A: Physical Sciences
An electric field solver based on a finite volume method using refined structural mesh is proposed to implement a quadtree structure and estimate the electric flux in the mesh cell. Numerical experiments were carried out using uniform and non-uniform meshes to assess quality of numerical modeling. The proposed method of verification of the quality of numerical calculations based on circular symmetry of the electrical capacitance tomography (ECT) probe allows to assess the effectiveness of mesh refinement and to reduce the number of mesh elements. Experiments showed that even a moderate level of mesh refinement is sufficient to significantly reduce the simulation error that occurs in modeling of cylindrical probes. The reduced number of mesh elements and applied implementation of the quadtree ensures high speed of forward problem calculations.
A desirable feature of an electrical capacitance tomography system is the adaptation possibility to any sensor configuration and measurement mode. A run-time reconfiguration of a system for electrical capacitance tomography is presented. An original mechanism is elaborated to reconfigure, on the fly, a modular EVT4 system with multiple FPGAs installed. The outlined system architecture is based on FPGA programmable logic devices (Xilinx Spartan) and PicoBlaze soft-core processors. Soft-core processors are used for communication, measurement control and data preprocessing. A novel method of FPGA partial reconfiguration is described, in which a PicoBlaze soft-core processor is used as a reconfiguration controller. Behavioral reconfiguration of the system is obtained by providing run-time access to the program code of a soft-core control processor. The tests using EVT4 hardware and different algorithms for tomographic scanning were performed. A test object was measured using 2D and 3D sensors. The time and resources required for the examined reconfiguration procedure are evaluated.