Hoon Kwon

Dr. Hoon Kwon

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2023 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
YCYuri Cho
Yuri Cho
JCJin Woo Choi
Jin Woo Choi
HKHoon Kwon
Hoon Kwon
KKKun Yung Kim
Kun Yung Kim
BLByung Chan Lee
Byung Chan Lee
RAResearch Committee of the Korean Liver Cancer Association
Research Committee of the Korean Liver Cancer Association
Cho Y, et al. Korean J Radiol. 2023 Jun;24:e35. https://doi.org/10.3348/kjr.2023.0385

30 September 2023 in Journal of Liver Cancer
Verified
Journal Article
Open access
PDF file
YCYuri Cho
Yuri Cho
JCJin Woo Choi
Jin Woo Choi
HKHoon Kwon
Hoon Kwon
KKKun Yung Kim
Kun Yung Kim
BLByung Chan Lee
Byung Chan Lee
RAResearch Committee of the Korean Liver Cancer Association
Research Committee of the Korean Liver Cancer Association
Transarterial chemoembolization (TACE) was introduced in 1977 with the administration of chemotherapeutic agent to gelatin sponge particles through the hepatic artery in patients with hepatocellular carcinoma (HCC) and was established as conventional TACE using Lipiodol in the 1980s. In the 2000s, drug-eluting beads were developed and applied clinically. Currently, TACE is a commonly used non-surgical treatment modality for patients with HCC who are unsuitable for curative treatment. Considering the vital role of TACE in the management of HCC, it is crucial to organize current knowledge and expert opinions regarding patient preparation, procedural techniques, and post-treatment care in TACE, which can enhance therapeutic efficacy and safety. A group of 12 experts in the fields of interventional radiology and hepatology, convened by the Research Committee of the Korean Liver Cancer Association (KLCA), has developed expert consensus-based practical recommendations in TACE. These recommendations have been endorsed by the Korean Society of Interventional Radiology and provide useful information and direction in performing TACE procedure as well as pre- and post- procedural patient care.

1 October 2020 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
RLRang Lee
Rang Lee
CJChang Ho Jeon
Chang Ho Jeon
CKChang Won Kim
Chang Won Kim
HKHoon Kwon
Hoon Kwon
JKJae Hun Kim
Jae Hun Kim
CPChan Yong Park
Chan Yong Park

29 August 2023 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Open access
SKSungho Koh
Sungho Koh
HKHoon Kwon
Hoon Kwon
LHLee Hwangbo
Lee Hwangbo
CKChang Won Kim
Chang Won Kim
SKSuk Kim
Suk Kim
SHSeung Baek Hong
Seung Baek Hong
To evaluate the effectiveness of track embolization using gelatin sponge slurry in percutaneous ultrasound (US)-guided liver biopsy. Among the 543 patients who underwent percutaneous US-guided liver biopsies between September 2018 and August 2021, 338 who did not undergo track embolization and 105 who underwent track embolization were included in the analysis. All procedures were performed with 18-gauge coaxial core biopsy needles. Patients' laboratory data were reviewed. Patients in both groups were subdivided into the following 2 groups: (a) those with targeted biopsy for a focal liver lesion and (b) those with nontargeted biopsy for a liver parenchyma. Moreover, postbiopsy events, such as transfusion and transarterial embolization, were assessed. To minimize selection bias, propensity score matching (PSM) was performed. After PSM, all factors that could affect bleeding risk were well-matched and well-balanced between the 2 groups (P > .474). In the non-track embolization group, 17 (16.2%) patients experienced major or minor bleeding-related adverse events (AEs). In contrast, in the track embolization group, only 5 (4.8%) patients experienced major or minor bleeding-related AEs, which was significantly lower than that in the non-track embolization group (P = .007). All 5 (4.8%) cases of major bleeding-related AEs were observed in the non-track embolization group (P = .024). In this study, a retrospective analysis was performed using PSM for percutaneous US-guided liver biopsy. Track embolization using gelatin sponge slurry is significantly superior in the prevention of bleeding-related AEs after US-guided liver biopsy.

20 October 2023 in Journal of Orthopaedic Science
Verified
Journal Article
Closed access
HKHoon Kwon
Hoon Kwon
JJJae Hoon Jang
Jae Hoon Jang
NMNam Hoon Moon
Nam Hoon Moon
SRSeung Joon Rhee
Seung Joon Rhee
DRDong Yeon Ryu
Dong Yeon Ryu
TATae Young Ahn
Tae Young Ahn

30 December 2020 in Journal of the Korean Society of Radiology
Verified
Journal Article
Open access
PDF file
CJChang Ho Jeon
Chang Ho Jeon
RLRang Lee
Rang Lee
HKHoon Kwon
Hoon Kwon
CKChang Won Kim
Chang Won Kim
JKJin Hyeok Kim
Jin Hyeok Kim
MBMiju Bae
Miju Bae
이창무, et al. J Korean Soc Radiol. 2021 Jul;82(4):923-935. https://doi.org/10.3348/jksr.2020.0116