Yan Zheng

Dr. Yan Zheng


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in Acta Astronautica
Verified
Journal Article
Closed access
YZYan Zheng
Yan Zheng
ZZZhicheng Zhou
Zhicheng Zhou
HHHai Huang
Hai Huang

6 October 2023 in Physica Scripta
Verified
Journal Article
Closed access
XZXiaoyan Zhang
Xiaoyan Zhang
WLWeipeng Li
Weipeng Li
SLShuai Li
Shuai Li
YZYan Zheng
Yan Zheng
This paper presents a novel piezoelectric XY micro-displacement scanning stage (MDSS), which features a parallel structure based on compliant mechanisms and has a compact configuration. Since the coupling problem between two motion axes, an innovative elliptical compliant restraint mechanism (ECRM) with a compact layout is proposed and utilized in XY MDSS to obtain high motion accuracy. And the XY MDSS can realize compact structure and lower input stiffness for a large workspace owing to the ECRM simultaneously. Due to the limited displacement of the piezoelectric stack actuator, compliant amplification mechanism is applied to achieve a large stroke. In order to estimate the static and dynamic characteristics theoretically, Castigliano’s second theorem and Lagrange’s method are utilized to establish the analytical models of the newfangled ECRM, compliant amplification mechanism, and XY MDSS. The finite element analysis and experimental tests are carried out to evaluate the performances of XY XDSS, and the results are all in correspondence with analytic solutions, which further validate the correctness of the analytical modeling methodologies. Experimental results show that the XY MDSS can realize a workspace of 58.8 μm × 51.5 μm with a resonance frequency of 576.5 Hz and nanometer-level resolution. The effectiveness of the designed ECRM is also proved simultaneously, which could well limit the coupling motion. The theoretical studies, finite element analysis, and experimental testing all demonstrate that the designed XY MDSS with ECRM has good performance while having a compact structure.

31 May 2021 in Journal of Vibration Engineering & Technologies
Verified
Journal Article
Closed access
PDF file
YZYan Zheng
Yan Zheng
ZZZhicheng Zhou
Zhicheng Zhou
HHHai Huang
Hai Huang

25 September 2023 in Actuators
Verified
Journal Article
Open access
PDF file
CLChao Liang
Chao Liang
WLWeipeng Li
Weipeng Li
HHHai Huang
Hai Huang
YZYan Zheng
Yan Zheng
This study proposes a method for designing a class of rotationally symmetric Stewart platforms (RSSPs) with an insensitive condition number (ICN), which is used to minimize the condition number to achieve a high accuracy for a multi-degree-of-freedom (multi-DOF) shaker. Considering the rotational symmetry of RSSPs, an analytical relationship between the architecture parameters and transfer coefficients is first established. Then, the decoupling conditions of the RSSPs are derived, and the transfer coefficient formulas are simplified by the given decoupling conditions and iso-length assumption. Following further analyses and discussions, the ICN condition and analytical form of the condition number are provided. The area of the ICN (AICN) is, subsequently, derived to evaluate the insensitivity of the condition number. To validate the effectiveness of the method, a design example (ICN-RSSP), along with a numerical analysis, is implemented, and, finally, a multi-DOF shaker is developed. The results of the numerical analysis show a smaller condition number and a larger AICN than those of the RSSP, for comparison. And the experiment results of the multi-DOF shaker show a high accuracy of vibration waveform reproduction. The method can reduce the condition number of RSSPs, improve the insensitivity, and further improve the accuracy of the multi-DOF shaker.