Yanfang Fan

Yanfang Fan


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2024 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
XBXueyan Bai
Xueyan Bai
YFYanfang Fan
Yanfang Fan
RHRuixin Hao
Ruixin Hao
JYJiaquan Yu
Jiaquan Yu

25 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XBXueyan Bai
Xueyan Bai
YFYanfang Fan
Yanfang Fan
JHJunjie Hou
Junjie Hou
Wind power DC collection system, as a crucial component of wind farms, plays a vital role in ensuring the safe and stable operation of the entire wind farm. This paper proposes a reliability assessment method for wind power DC collection systems based on MLFTA-SMC. Firstly, it analyzes the topology and key equipment of wind power DC collection systems. Secondly, based on the topology of different wind power DC collection systems, it constructs multi-level fault tree models to calculate the comprehensive importance of different events, thus providing data support for subsequent reliability assessment. Then, it utilizes the MLFTA-SMC method to assess and analyze the reliability of different wind power DC collection system topologies. Finally, taking a 100 MW wind farm in Northwest China as an example, the proposed reliability assessment method is verified through simulation. The results indicate that this method exhibits good effectiveness and superiority.

29 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YSYao Sun
Yao Sun
YFYanfang Fan
Yanfang Fan
JHJunjie Hou
Junjie Hou
GSGuobing Song
Guobing Song
In modular multilevel converters-based DC power grid, short faults develop rapidly and have complex characteristics. The power electronic converter has a limited ability to withstand overcurrent. So, protection needs to quickly identify the fault area in an extremely short time. Non-unit protection based on traveling waves has the advantage of rapid action, but its ability to resist fault resistance needs to be improved. To improve protection performance, a non-unit protection based on the ratio of initial fault voltage reversal wave (IVRW) tangent envelope area is proposed. First, the waveform distortion characteristics and the waveform characteristics of the IVRW at different fault locations are analyzed. Second, the tangent envelope area ratio is used to characterize the waveform distortion characteristics, which gets rid of the influence of fault resistance. Then, a fault identification criterion is constructed. And a protection scheme based on the tangent envelope area ratio is proposed by combining the start criterion and the fault pole criterion. Simulation results show that the proposed scheme has strong resistance to fault resistance and the setting value does not depend on simulation. In addition, the scheme can still effectively identify the protection area under weak boundaries and strong noise interference.

13 February 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XQXiaohua Qin
Xiaohua Qin
JHJunjie Hou
Junjie Hou
YFYanfang Fan
Yanfang Fan
GSGuobing Song
Guobing Song
XWXiaofang Wu
Xiaofang Wu
The current limiting control strategy of modular multilevel converters in flexible DC power grids can effectively reduce the requirements for line protection speed and the breaking capacity of DC circuit breakers (DCCB). However, it can easily lead to the interruption of power transmission at non-fault terminals and expanding the scope of the fault impact. Secondly, it did not consider the severity of matching faults, which may lead to excessive suppression of fault currents and reduce the sensitivity of the protection system. Therefore, this paper proposes an active current limiting control (ACLC) strategy with fault identification capability to further improve its selectivity and adaptability. Firstly, the starting element in the ACLC selectively identify fault areas based on the difference in the slope of the first backward traveling wave (TW) of the current. Secondly, a current limiting coefficient is constructed based on the slope of the first backward TW of current to achieve fault current limiting. On this basis, setting amplitude control to improve the adaptability of ACLC to fault resistance. Finally, a complete fault handling scheme was proposed, including ACLC, fault identification and fault isolation. The simulation results show that the proposed ACLC strategy is selective while reducing the technical requirements of DCCB. In addition, the adaptability of ACLC to fault resistance has also been improved.