Objective: To describe the relationship between implantation-associated trauma and postoperative speech perception scores among adult and pediatric patients undergoing cochlear implantation using conventional length electrodes and minimally traumatic surgical techniques. Study Design: Retrospective chart review (2002-2010). Setting: Tertiary academic referral center. Patients: All subjects with significant preoperative low-frequency hearing (≤70 dB HL at 250 Hz) who underwent cochlear implantation with a newer generation implant electrode (Nucleus Contour Advance, Advanced Bionics HR90K [1J and Helix], and Med El Sonata standard H array) were reviewed. Intervention(s): Preimplant and postimplant audiometric thresholds and speech recognition scores were recorded using the electronic medical record. Main Outcome Measure(s): Postimplantation pure tone threshold shifts were used as a surrogate measure for extent of intracochlear injury and correlated with postoperative speech perception scores. Results: Between 2002 and 2010, 703 cochlear implant (CI) operations were performed. Data from 126 implants were included in the analysis. The mean preoperative low-frequency pure-tone average was 55.4 dB HL. Hearing preservation was observed in 55% of patients. Patients with hearing preservation were found to have significantly higher postoperative speech perception performance in the CI-only condition than those who lost all residual hearing. Conclusion: Conservation of acoustic hearing after conventional length cochlear implantation is unpredictable but remains a realistic goal. The combination of improved technology and refined surgical technique may allow for conservation of some residual hearing in more than 50% of patients. Germane to the conventional length CI recipient with substantial hearing loss, minimizing trauma allows for improved speech perception in the electric condition. These findings support the use of minimally traumatic techniques in all CI recipients, even those destined for electric-only stimulation.
Objective To investigate cochlear implant performance outcomes among patients with Neurofibromatosis type 2 (NF2). Study Design Retrospective case series, patient questionnaire, and systematic review of the literature. Setting Tertiary academic referral center. Patients All patients with NF2 having an anatomically intact ipsilateral cochlear nerve who underwent cochlear implantation (CI). Intervention(s) Cochlear implantation. Main outcome measures Postimplantation audiometric performance and patient perceived benefit. Results Ten patients met study criteria. The median duration of follow-up after CI was 42 months (mean, 46.9 mo; range, 12–97 mo). Five patients received previous microsurgical resection of their ipsilateral vestibular schwannoma, 4 underwent previous stereotactic radiosurgery, and 1 patient had no tumor treatment before CI. Nine subjects achieved sound awareness, 6 attained open-set speech recognition and 7 are daily users. Variables including prolonged auditory deprivation, cochlear ossification, unfavorable electrical promontory stimulation testing, and useful contralateral hearing were associated with poor cochlear implant performance. No statistical associations were found between open-set recognition capacity and previous tumor management strategy, surgical approach, or ipsilateral tumor size. Conclusion Cochlear implantation is an attractive alternative to auditory brainstem implantation for hearing rehabilitation in patients with NF2. Approximately 70% of patients achieve open-set speech discrimination, many scoring at the ceiling of audiometric testing. Given a favorable risk profile and superior audiometric outcomes, CI should be strongly considered in patients with nonserviceable hearing who have an anatomically intact cochlear nerve, whereas auditory brainstem implantation should be reserved for patients with evidence of cochlear nerve loss. Akin to conventional cochlear implant recipients, prolonged hearing loss, unfavorable electrophysiological testing, and cochlear ossification may predict poor subject performance. Finally, useful hearing in the contralateral ear may present a barrier to daily device use.
Introduction Despite successful preservation of low-frequency hearing in patients undergoing cochlear implantation (CI) with shorter electrode lengths, there is still controversy regarding which electrodes maximize hearing preservation (HP). The thin straight electrode array (TSEA) has been suggested as a full cochlear coverage option for HP. However, very little is known regarding its HP potential. Methods A retrospective review was performed at two tertiary academic medical centers, reviewing the electronic records for 52 patients (mean, 58.2 yr; range, 11–85 yr) implanted with the Cochlear Nucleus CI422 Slim Straight (Centennial, CO, USA) electrode array, referred to herein as the thin straight electrode array or TSEA. All patients had a preoperative low-frequency pure-tone average (LFPTA) of 85 dB HL or less. Hearing thresholds were measured at initial activation (t1) and 6 months after activation (t2). HP was assessed by evaluating functional HP using a cutoff level of 85 dB HL PTA. Results At t1, 54% of the subjects had functional hearing; 33% of these subjects had an LFPTA between 71 and 85 dB HL, and 17% had an LFPTA between 56 and 70 dB HL. At t2, 47% of the patients had functional hearing, with 31% having an LFPTA between 71 and 85 dB HL. Discussion Preliminary research suggests that the TSEA has the potential to preserve functional hearing in 54% of patients at t1. However, 22% (n = 6) of the patients who had functional hearing at t1 (n = 28) lost their hearing between t1 and t2. Further studies are needed to evaluate factors that influence HP with the TSEA electrode and determine the speech perception benefits using electric and acoustic hearing over electric alone.