This study delves into the acoustic environment within dental clinics, particularly focusing on the impact of extraoral suction devices employed for infection control amid the COVID-19 pandemic. The research encompasses a comprehensive investigation, including a questionnaire survey of dental professionals, sound level measurements at suction device openings, acoustic imaging, and a detailed analysis of sound levels and their spectral characteristics during dental procedures. Additionally, ambient sound levels within clinical settings were monitored over two consecutive days. The findings reveal notable observations. Dental professionals expressed concerns regarding increased sound levels and associated distress caused by extraoral suction device operation. Objective measurements identified varying A-weighted sound pressure levels ranging from 86.0 dB to 96.7 dB at suction device openings, highlighting elevated sound pressure levels and a wide frequency range, especially in the vicinity of both the dentist and the patient’s facial area during dental aerosol procedures. On the other hand, for the entire clinical room, the equivalent continuous A-weighted sound pressure level during the consultation hours was not considered problematic. In light of these findings, it becomes evident that there is a pressing necessity to refine the acoustic characteristics of extraoral suction devices to foster a more accommodating acoustic environment for both patients and dental healthcare professionals within dental clinics.
Fear and anxiety among patients are sometimes evoked in dental clinics due to the sound of dental drills. This study aimed to explore the impact of age-related hearing loss in the extended high frequency (EHF) range above 8 kHz on individuals' subjective discomfort towards dental drill noise. After measuring pure-tone audiometric thresholds at both conventional and extended high frequencies, we used a psychoacoustic approach to evaluate subjective impressions of four dental drill sound stimuli, which featured varying frequency components, in 62 participants (aged 12–67 years). We found a significant decrease in hearing sensitivity within the EHF range as age increased, with notable differences in hearing thresholds at 14 kHz between teenage and older adults exceeding 65 dB. Furthermore, significant differences were observed between younger and older (above 40 years) participants in the subjective impressions of dental drill noise, emphasizing age as a critical factor in the perception of high frequency components. Consequently, age may influence the unpleasantness of dental drilling noise. Compared to older individuals, young participants may exhibit increased fear of dental procedures owing to physiological factors. These results underscore the need for age-appropriate noise control strategies in dental clinics to mitigate anxiety and improve patient comfort.
High-pitched noise generated by dental air turbine handpieces (ATHs) causes discomfort and anxiety, discouraging dental visits. Understanding the time-dependent noise generation mechanism associated with compressed airflow in ATHs is crucial for effective noise reduction. However, the direct investigation of airflow dynamics within ATHs is challenging. The transient-state modeling of computational fluid dynamics (CFD) simulations remains unexplored owing to the complexities of high rotational speeds and air compressibility. This study develops a novel CFD framework for transient (time-dependent) modeling under high-speed rotational conditions. Simulations were performed using a three-dimensional model reconstructed from a commercial ATH. Simulations were conducted at 320,000 rpm using a novel framework that combines the immersed boundary and building cube methods. A fine 0.025 mm mesh spacing near the ATH, combined with supercomputing resources, enabled the simulation of hundreds of millions of cells. The simulation results were validated using experimental noise measurements. The CFD simulation revealed transient airflow and aeroacoustic behavior inside and around the ATH that closely matched the prominent frequency peaks from the experimental data. This study is the first to simulate the transient airflow of ATHs. The proposed CFD model can accurately predict aeroacoustics, contributing to the future development of quieter and more efficient dental devices.
Dental treatment can induce stress and discomfort in patients; however, how physiological responses evolve over the course of treatment remains unclear. This study investigated physiological and real-time subjective responses during dental treatment, focusing on the temporal characteristics of fingertip skin temperature (TMP) and electrodermal activity (EDA) and their relationships with subjective responses. Fourteen participants were exposed to extraoral suction noise and subsequently underwent dental scaling. TMP and EDA were continuously recorded using wearable sensors, while real-time discomfort (RTD) was assessed using a continuous subjective rating device. Questionnaires were administered before and after treatment. TMP decreased during the Noise-only and Treatment phases; in most participants, the minimum temperature was observed after treatment completion. EDA increased during and after treatment, with inter-individual variability in peak timing and temporal course. Whereas RTD rapidly decreased after treatment completion, physiological responses persisted into the Post-treatment phase. The results suggest that TMP and EDA exhibit different temporal characteristics. Temporal analyses provided additional information on response timing, persistence, and inter-individual variability beyond that obtained from phase-averaged analyses. Although these findings are exploratory, they suggest the importance of examining whether quantitative measures derived from continuous physiological signals adequately represent the temporal course of the underlying physiological responses.