Mehmet Ozgur Ozemre

Dr. Mehmet Ozgur Ozemre

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2019 in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
Verified
Journal Article
Closed access
PDF file
HPHande Pamukçu
Hande Pamukçu
ÖPÖmür Polat-Özsoy
Ömür Polat-Özsoy
AGAyşe Gülşahi
Ayşe Gülşahi
MOMehmet Ozgur Ozemre
Mehmet Ozgur Ozemre

1 October 2018 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
MOMehmet Ozgur Ozemre
Mehmet Ozgur Ozemre
AGAyse Gulsahi
Ayse Gulsahi
OOOzemre Mehmet Ozgur
Ozemre Mehmet Ozgur
The aim of this study was to investigate the accuracy of the new stitching feature of the Morita 3D Accuitomo device by comparing it with the I-CAT device and real measurements. Eight dry skulls were used in this study. The full scan mode of an I-CAT device and the new stitching feature of the Morita 3D Accuitomo device were used to obtain full head CBCT images, and the linear distances between the selected anatomical sites were measured by two observers. The real distances were measured directly on the skulls using digital calipers. Statistical analyses were performed using the intraclass correlation coefficient (ICC) and Bland-Altman Limits of Agreement. High or perfect agreement was detected between the CBCT images and real measurements. The Bland Altman Limits of Agreement analysis revealed that the stitched coronal and sagittal images of the Morita might differ by >1.54–1.67 or <0.01 mm from the real measurements. The stitched images of the Morita CBCT device showed perfect agreement with both real measurements and the images of an I-CAT full head scan. After the evaluation of the radiation doses received from stitching sectional images, this device may be used to obtain full head images.

12 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
NTNazan Kocak Topbas
Nazan Kocak Topbas
kıvanç of kamburoğlukıvanç of kamburoğlu
kıvanç of kamburoğlu
AEAyşe Tuğba Ertürk-Avunduk
Ayşe Tuğba Ertürk-Avunduk
MOMehmet Ozgur Ozemre
Mehmet Ozgur Ozemre
NENejlan Eratam
Nejlan Eratam
EÇEsra Ece Çakmak
Esra Ece Çakmak
The aim of this study was to compare the diagnostic performance of clinical visual examination (ICDAS II), digital periapical radiography (PR), near infrared light transillumination (NIR-LT), and laser fluorescence (LF) to microcomputed tomography (Micro-CT) which is the reference standard for the detection of non-cavitated occlusal enamel and dentin caries in third molar teeth. Potential participants were consecutively recruited. In this prospective study, 101 third molars of 101 patients were examined; the molars had non-cavitated occlusal caries which required extraction. ICDAS II, PR, NIR-LT and LF examinations were carried out by two blinded examiners. Reference standard was determined by micro-CT imaging seven days after extraction. Accuracy rate, sensitivity, specificity, predictive values and areas under receiver operating characteristic (ROC) curves (Az) were statistically analyzed. Nonparametric variables were subjected to the Kruskal–Wallis Test. Significance level was set as p < 0.05. NIR-LT had the highest sensitivity (99.67–99.67%) and accuracy (78.22–77.23%) for the determination of occlusal enamel caries according to examiners 1 and 2, respectively. LF method had the highest sensitivity (70.83–54.17%) and accuracy (66.34–59.41%) for determining occlusal dentin caries according to examiners 1 and 2, respectively. The ROC curve (Az) value ranged between 0.524 and 0.726 for the different methods tested. Most effective methods for the diagnosis of occlusal enamel and dentin caries were determined to be NIR-LT and LF pen methods, respectively. The present prospective clinical study showed that NIR-LT and LF-Pen were a reliable modality for the detection of occlusal enamel and dentin caries without ionizing radiation.

30 November 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MOMehmet Ozgur Ozemre
Mehmet Ozgur Ozemre
HKhazal karslıoğlu
hazal karslıoğlu
kıvanç of kamburoğlukıvanç of kamburoğlu
kıvanç of kamburoğlu
Background/Objectives: This study aimed to investigate the relationship between the mesiobuccal root canal configuration (MB RCC), the interorifice distance (IOD) and the corresponding root and other root lengths of the permanent maxillary first molars; Methods: Cone beam computed tomography (CBCT) images were acquired between 2020 and 2023 for different purposes unrelated to this study. Overall, 1550 CBCT images were retrospectively evaluated. A dentomaxillofacial radiologist with 15 years of experience evaluated the CBCT images and performed the measurements; Results: According to the MB RCC, there was no statistically significant difference between the Vertucci type II and Vertucci type IV groups in terms of the mean age and sex distribution (p = 0.694 and p = 0.273). There was no statistically significant difference in the IOD between the MB RCC groups (p = 0.755). Moreover, according to the MB RCC, there was no statistically significant difference between the Vertucci type II and Vertucci type IV groups in terms of the mesiobuccal, distobuccal, palatinal, and mean root lengths (p > 0.05); Conclusions: There was no association between the IOD and the type of RCC in the maxillary first molars. New studies conducted by collecting data from different centers to explore the different morphological features of maxillary first molars and detect their anatomical differences will provide more reliable and accurate results.

27 September 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
MOMehmet Ozgur Ozemre
Mehmet Ozgur Ozemre
JBJale Bektaş
Jale Bektaş
HYHüseyin Yanik
Hüseyin Yanik
LBLütfiye Baysal
Lütfiye Baysal
HKHazal Karslioğlu
Hazal Karslioğlu
The anatomical relationship between the maxillary sinus and maxillary molars is critical for planning dental procedures such as tooth extraction, implant placement and periodontal surgery. This study presents a novel artificial intelligence-based approach for the detection and classification of these anatomical relationships in cone beam computed tomography (CBCT) images. The model, developed using advanced image recognition technology, can automatically detect the relationship between the maxillary sinus and adjacent molars with high accuracy. The artificial intelligence algorithm used in our study provided faster and more consistent results compared to traditional manual evaluations, reaching 89% accuracy in the classification of anatomical structures. With this technology, clinicians will be able to more accurately assess the risks of sinus perforation, oroantral fistula and other surgical complications in the maxillary posterior region preoperatively. By reducing the workload associated with CBCT analysis, the system accelerates clinicians’ diagnostic process, improves treatment planning and increases patient safety. It also has the potential to assist in the early detection of maxillary sinus pathologies and the planning of sinus floor elevation procedures. These findings suggest that the integration of AI-powered image analysis solutions into daily dental practice can improve clinical decision-making in oral and maxillofacial surgery by providing accurate, efficient and reliable diagnostic support.

16 December 2020 in Current Medical Imaging
Verified
Journal Article
Closed access
PDF file
KOKaan Orhan
Kaan Orhan
DYDilek Yılmaz
Dilek Yılmaz
MOMehmet Ozgur Ozemre
Mehmet Ozgur Ozemre
kıvanç of kamburoğlukıvanç of kamburoğlu
kıvanç of kamburoğlu
OGOrhan Gulen
Orhan Gulen
AGAyse Gulsahi
Ayse Gulsahi
Objectives: To evaluate impacted mandibular third molar tooth region and obtain linear measurements using CBCT images and to assess the relationship between the impacted third molar and the mandibular canal. Methods: CBCT scans of 351 patients (208 females, 143 males) were assessed. Age, gender, and impaction site were recorded for each patient. The relationship of third molars with the vertical axis of second molars, 2nd molar resorption and the relationship between third molar apices and the mandibular canal were assessed. In addition, the distance between ramus and second molar, mesiodistal width of the third molar, the angle between third molar and second molar, and width of the third molar capsule were measured. Binary Logistic Regression, Chi-Square Test, and General Linear Model were used for statistical analysis. Results: The highest percentage of impaction was found for mesioangular followed by transversal and vertical. The transversal impacted third molars revealed a significant association with adjacent second molar root resorption (p<0.001). There was a statistical significance between the second molar resorption and distance between ramus and second molar (p<0.001). The mesioangular impacted third molars revealed significant relation with the mandibular canal (p<0.05). The most frequent variation found was the dental canal followed by the retromolar canal. In general, higher measurement values were obtained for men when compared to women (p<0.05). Conclusion: CBCT assessment of the third molar region provided useful information regarding impacted mandibular third molar surgery operations.