The heat transmission through a fabric during the measurement of thermal resistance was simulated by a novel heterogeneous model that was constructed according to the structure of ThermolabII Tester KES-F7. In this model, the heat transmissions along the longitudinal and transverse directions of yarn were treated independently. The material constants of fabrics, such as mass density, specific heat, thermal conductivity and thickness, were used as parameters for simulation in this fabric model. The validity of this model was then confirmed by the high consistency between the heat flux obtained from experiment and simulation, with the average difference ratio lower than 5%. The simulation results suggested that the guard area could effectively reduce the horizontal heat leakage from the test plate when the experimental fabric was thin. Only less than 8% of heat leaked in the one-layer case, while the leakage was significantly aggravated when more layers of fabric were stacked, resulting in the considerably lower thermal insulation achieved in both experiment and simulation compared with that in real fabrics. The temperature distribution in the model also implied that the longitudinal and transverse thermal conductivity of yarn exerted great effect on the heat leakage during the measurement. Moreover, for multilayers consisting of different fabrics, the laying sequence could obviously influence the heat leakage and, consequently, change the obtained thermal resistance.
A three-dimensional upwind conservation element and solution element method (CESE) in cylindrical coordinates is first developed to effectively solve the unsteady reactive Euler equations governing a hydrogen–air rotating detonation engine (RDE) with coaxial structures. The effects of the annular width on the structure of the detonation front and the relationship between the thrust and mass flow rate are then investigated. Additionally, RDEs with various injection conditions are systematically analyzed regarding flow patterns and propulsion performance. The results reveal a positive correlation between the specific impulse and the area ratio of the injection slot to the head-end wall. Nevertheless, the specific impulse shows minimal dependence on the injector slot’s location when the area ratio is constant. Ultimately, it is concluded that the area ratio between the injector and the head-end wall is critical in determining the loss of specific impulse.
An air layer enclosed at the interface was largely responsible for the insulation results of multilayer fabrics obtained from experiments. In this study, a three-dimensional finite element method model, in which the air layer enclosed at the interface of multilayer fabrics was ignored, was developed to calculate the fabric thermal resistance, and the result obtained from the fabric model was independent of the air. A Thermolab II Tester KES-F7 was also used to measure the thermal resistance of fabrics, and the experimental results were influenced by the air layer. By comparing the simulation and experimental result, the air layer thermal resistance was determined, and then an estimating equation, which can be used to estimate the fabric and air layer thermal resistance for multilayer fabrics, was proposed. The results suggested that the surface roughness of fabrics was strongly related to the air layer thermal resistance, with a linear relationship between them. Moreover, for multiple layers stacked by different fabrics, the air layer thermal resistance at the interface was mainly decided by the fabric with the rougher surface. An estimating equation was also developed to predict the thermal resistance of multilayer fabrics and good correlation between predicted and experimental values was observed.