Jose Gonzalez-Rodriguez

Dr. Jose Gonzalez-Rodriguez

School of Chemistry, University of Lincoln, Lincoln, LN6 7TS, UK
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2008 in Journal of Chromatography A
Verified
Journal Article
Closed access
KSKarina L. Sobeih
Karina L. Sobeih
MBMark Baron
Mark Baron
Jose Gonzalez-RodriguezJose Gonzalez-Rodriguez
Jose Gonzalez-Rodriguez

22 November 2019 in Nanoscale
Verified
Journal Article
Closed access
PDF file
RORafael Del Caño Ochoa
Rafael Del Caño Ochoa
JGJose M. Gisbert-González
Jose M. Gisbert-González
Jose Gonzalez-RodriguezJose Gonzalez-Rodriguez
Jose Gonzalez-Rodriguez
GSGuadalupe Sanchez-Obrero
Guadalupe Sanchez-Obrero
RMRafael Madueño
Rafael Madueño
TPTeresa Pineda
Teresa Pineda
The highly packed cetyltrimethylammonium bromide bilayer on the surface of gold nanorods synthesized by the seed-mediated procedure hampers the complete ligand exchange under experimental conditions that preserves the stability of the dispersions.

1 April 2019 in Separation and Purification Technology
Verified
Journal Article
Closed access
SMSamuel K. Mamo
Samuel K. Mamo
MEMathieu Elie
Mathieu Elie
MBMark G. Baron
Mark G. Baron
ASAndrew M. Simons
Andrew M. Simons
Jose Gonzalez-RodriguezJose Gonzalez-Rodriguez
Jose Gonzalez-Rodriguez

5 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
SMSamuel Kassahun Mamo
Samuel Kassahun Mamo
Jose Gonzalez-RodriguezJose Gonzalez-Rodriguez
Jose Gonzalez-Rodriguez
The explosive triacetone triperoxide (TATP), which can be prepared from commercially readily available reagents following an easy synthetic procedure, is one of the most common components of improvised explosive devices (IEDs). Molecularly-imprinted polymer (MIP) electrochemical sensors have proved useful for the determination of different compounds in different matrices with the required sensitivity and selectivity. In this work, a highly sensitive and selective molecularly imprinted polymer with electrochemical capabilities for the determination of TATP has been developed. The molecular imprinting has been performed via electropolymerisation onto a glassy carbon electrode surface by cyclic voltammetry from a solution of pyrrole functional monomer, TATP template and LiClO4. Differential Pulse Voltammetry of TATP, with LiClO4 as supporting electrolyte, was performed in a potential range of −2.0 V to +1.0 V (vs. Ag/AgCl). Three-factor two-level factorial design was used to optimise the monomer concentration at 0.1 mol∙L−1, template concentration at 100 mmol∙L−1 and the number of cyclic voltammetry scan cycles to 10. The molecularly imprinted polymer-modified glassy carbon electrode demonstrated good performance at low concentrations for a linear range of 82–44,300 µg∙L−1 and a correlation coefficient of r2 = 0.996. The limits of detection (LoD) and quantification (LoQ) achieved were 26.9 μg∙L−1 and 81.6 μg∙L−1, respectively. The sensor demonstrated very good repeatability with precision values (n = 6, expressed as %RSD) of 1.098% and 0.55% for 1108 and 2216 µg∙L−1, respectively. It also proved selective for TATP in the presence of other explosive substances such as PETN, RDX, HMX, and TNT.

1 November 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
RJRebeca Jiménez-Pérez
Rebeca Jiménez-Pérez
Jose Gonzalez-RodriguezJose Gonzalez-Rodriguez
Jose Gonzalez-Rodriguez
MGMaría-Isabel González-Sánchez
María-Isabel González-Sánchez
BGBeatriz Gómez-Monedero
Beatriz Gómez-Monedero
EDELMIRA VALEROEDELMIRA VALERO
EDELMIRA VALERO

1 September 2013 in Forensic Science International
Verified
Journal Article
Closed access
Jose Gonzalez-RodriguezJose Gonzalez-Rodriguez
Jose Gonzalez-Rodriguez
GFG. Fowler
G. Fowler